品牌
其他厂商性质
芜湖市所在地
RDP2-J3型恒功率电热带
Model RDP2-J3 constant watt heating cable
型号含义 Model explanation
单位长度功率 Unit length watt:W/m |
绝缘层代号:J3-F46氟塑料 Insulation code: Fluroplastic |
Q:加强型,普通型(省略)Reinforced, common(omitted) |
2:芯数,单相220V 工作电压 2 core no., single phase 220V working voltage |
RDP:并联型电热带 Parallel heating cable |
例:
RDP2-J3-20:表示绝缘材料为F46氟塑料,20W//m的单相恒功率电热带。
RDP2(Q)-J3-30:表示绝缘材料为F46氟塑料,30W/m加强型恒功率电热带。
E.g:
RDP2-J3-20:insulation material is F46,20w/m single-phase constant watt heating cable
RDP2(Q)-J3-30:Insulation material is F46,30w/m reinforced constant watt heating cable
产品结构与工作原理
Working principle
电源母线为二根平行绝缘铜线,在内绝缘层上缠绕电热丝,并将电热丝每隔一定距离(即“发热节长”)与母线连接,形成连续并联电阻(见图1),母线通电后,各并联电阻发热,因而形成一条连续的加热带。
The bus wires are two paralleled insulated copper wires, the heating fiber wraps around the inner insulation layer. And the heating fiber connects to the bus wires at interval points(heating section length),so each section is paralleled connection and generate the heat continuously.
规格及主要技术特性 Dimension and main technical features
产品型号 Model | 额定电压 Reted voltage (V) | 额定功率 Rated watt (W/m) | 发热节长 Heating section length (mm) | 使用长度 Max. usable length (m) | 流体维持温度 Max.holding temperature for the liquid(℃) | |
普通型 Common | 加强型 Reinforced | |||||
RDP2-J3-10 | RDP2(Q)-J3-10 | 220 | 10 | 1310 | 225 | 130 |
RDP2-J3-20 | RDP2(Q)-J3-20 | 220 | 20 | 930 | 160 | 120 |
RDP2-J3-30 | RDP2(Q)-J3-30 | 220 | 30 | 730 | 145 | 95 |
RDP2-J3-40 | RDP2(Q)-J3-40 | 220 | 40 | 630 | 126 | 75 |
注:流体维持温度,是指管道内介质需要维持的工作温度,一般不宜超过本表规定值。
Note: The max. holding temperature is the maximum temperature needed for the media in the pipes, not exceeding the value stated in this table.
常态绝缘电阻; ≧50MΩ/hm Normal insulation resistance:: ≧50MΩ/hm
介电强度:-2000V 50Hz/1min Dialectic force: -2000V 50Hz/1min
绝缘层材料:F46氟塑料 Insulation:F46
F46耐高:205℃ F46 Max. temperature:205℃
防爆标志:e II T3 Anti-explosive: e II T3
防护等级:IP54 Protection grade:IP54
产品截面尺寸 Section size
RDP2-J3-10 普通型 RDP2(Q)-J3-10 加强型 RDP2-J3-10 Common RDP2(Q)-J3-10 Reinforced
RDP2-J3-20 普通型 RDP2(Q)-J3-20 加强型 RDP2-J3-20 Common RDP2(Q)-J3-20 Reinforced
RDP2-J3-30 普通型 RDP2(Q)-J3-30 加强型 RDP2-J3-30 Common RDP2(Q)-J3-30 Reinforced
RDP2-J3-40 普通型 RDP2(Q)-J3-40 加强型 RDP2-J3-40 Common RDP2(Q)-J3-40 Reinforced
图2 RDP2-J3型电热带截面尺寸
Fig:2 Model RDP2-J3 heating cable section size
产品特点及应用场合
Features and applications
恒功率电热带单位长度的发热量恒定,使用的电热带越长,输出的总功率越大,该电热在现场能按实际需要长度任意剪切此外富有柔软性,可以方便地紧贴管道表面敷设。电热带外层的编织层不仅起着传热和散热作用提高电热带的整体强度,同时还能作为安全接地线。
恒功率电热带与温控器配合使用时,能较精确维持管道内的介质温度。
The constant watt heating cable can set off constant heat. The more the cable, the bigger the heat generated. The cable can be cut in any length when necessary. It can laid-up against the surface of the pipes. The outer braid layer is used for dissipate heat as well as safe ground wire.
If it is used together with temperature controller, the cable can hold the temperature in the pipes precisely.
加强型电热带是在普通电热带外层包覆一层绝缘层,其余结构及原理和普通型电热带相同,加强型电热带较普通电热带防腐能力强,机械强度更高,它更适合于防爆场合的埋敷地下或有腐蚀性气体的场合使用。
The reinforced heating cable is derived from wrapping the insulation layer outside the common heating cable, and other structure is the same. The reinforced cable has more resistance to erosion, mechanical strength and suitable in anti-explosive place or in erosivegas.
由于母线截面积有限,为避免太大引起功率下降,每根电热带的使用长度按表1选用;当选用如图3的供电方法时,每个电源点的管线伴热长度为电热带使用长度的两倍。 本电热带适用管道,阀门,泵体的伴热,防冻和保温,或者维持仪表管线的工艺温度,如 1、在正常情况下连续流动的低凝固管线使用,可避免介质因停止流动而凝固。 2、需要严格控制作业温度的液体管线的伴热和保温(须配用温度控制器)。 3、寒冻地区自来水管线及阀门的防冻,排水管,抽水管和冷凝管路的防冻。 4、沿海井台管道的伴热防冻。 5、一般管线仪表管线的伴热保温。 6、井口采油树伴热(取代水套炉),污水井伴热。 7、机场跑道防冰雪封冻。 8、混凝土预制件防冻养护。 | As the bus line cross section is limited, in order to avoid the decreasing of the capacity, refer to Table 1 to the proper length for each heating cables. If the power supply is as shown in figure3 ,each heating length from each power point is twice the maximum usable length. The heating cable is used for heating or holding the temperature of pipes, valves and pumps. For example: 1. Applicable on the pipes in which flowing liquid will not become solid due to coolness. 2. Heating and holding the temperature precisely for the liquid pipelines. 3. Avoid freezing of the gape water pipelines, drainage pipes and condensing pipes. 4. Heating and anti-freezing of the sea oil pipelines 5. Holding the temperature of the common pipelines and instrument pipes. 6. Heating the oil well and sewage wells 7. Heating the airport road to avoid ice freezing. 8. Heating the concrete prepared parts. |
防爆说明
Anti-explosive
该单相恒功率电热带按GB3836.1-83和GB3836.3-83即爆炸性环境用防爆电器设备“通用要求”和“增安型电器设备e”要求设计制造,防爆等级为“e II T3”,产品具有不延燃性,并通过密闭式电热器要求的试验与防爆电器附件配套后,适用于不受外力直接冲击的工厂一区、二区爆炸性气体混合物T3组合物场所使用。 | This constant watt heating cable is made as per GB3836.1-83 and GB3836.3-83, i. e, general requirement for the anti-explosive equipment and safe electric apparatus grade E. The anti-explosive grade is “ e II T3”. Due to its non-extensive burning, the cable is used on the anti-explosive parts which are applicable in the area 1 and area 2 in factory under explosive gas mixture T3. |