Nano LC System

MieuxTMNano LC System

参考价: 面议

具体成交价以合同协议为准
2021-09-28 09:48:29
184
产品属性
关闭
安捷来国际股份(香港)有限公司

安捷来国际股份(香港)有限公司

免费会员
收藏

组合推荐相似产品

产品简介

Nano LC System

详细介绍

Nano LC System
MieuxTM

Introducing the NewMieux!

Cutting edge pumping technology for outstanding stability andreproducibility

The Mieux System is an innovative system developed for nano-LCfor MS. This system is best suited for proteome, metabolome, anddrug metabolism analyses, as well as for high-separation andhigh-sensitivity analysis.

Gradient pumping exceeding50 nL/min.
Our unique pumping system can achieve a gradient of 50 nL/min.Direct pumping without using the splitter ensures less change inthe flow rate under conditions which produce pressure fluctuations(associated with column exchange), offering stable reproducibilityand makes it unnecessary to adjust the split ratio.

* Features
  • Unique pumping system, enabling a gradient of 50 nL/min withoutusing the splitter
  • Pressure monitor enables full-time monitoring of pumping state
  • Various programs (auto flash, auto refill, auto drain) enablethe System’s high-speed equilibrium and full-automatic pumping
  • Proprietary software enables full-automatic measurement for 1Dto 2D systems
  • Combining this system with the Spotter Mieux SP (OFF Line/LCMS)for MALDI-TOF MS enables spotting to a target plate andmicro-fractionation
  • Connectable to other types of MS
  • Unique nano-spray stage and nano-spray column holder available(optional)
Top of this page

* Connectable to other mass spectrometers
Applied Biosystems / MDS CIEX · Micromass· BRUKER DALTONICS · Thermo Fisher, and others
Top of this page

* Analysis data sample (Mieux+Q-Star Elite, t-BSA 50fmol Coverage 70%)
Top of this page

* Nano-spray stages and nano-spray holders for various MS systems
Nano Spray Stage for LCQNano Spray Stage for LTQNano Spray Stage Holder for LTQ, Esquire, Accu TOF
Top of this page

Mieux System
Configuration
Mieux-I Manual injection system. This system enablesdesalting condensation manually using the trap column.Gradient pump, nano-injection valve withactuator, control software, PC, analytical column, trap column
Mieux-II Auto injection system, which enables gradientanalysis after automatic sample injection and desalting.Gradient pump, single pump, auto sampler,trap column valve, control software, PC, analytical column, trapcolumn (*)
Mieux-III Direct injection system, which has beendeveloped for high-sensitivity detection of phosphoric peptides.Gradient pump, single pump, auto sampler(micro specifications), trap column valve, control software, PC,phosphoric peptide analytical column, trap column (*)
Mieux-IV Two-dimensional auto injection system. Thison-line two-dimensional system performs the single dimension ionexchange in a stepwise manner and two-dimensional reverse-phaseseparation and elution based on the gradient set-up.Gradient pump, single pump, auto sampler,trap column valve, ion exchange column valve, control software, PC,ion exchange column, analytical column, and trap column (*)
Mieux-V Two-dimensional auto injection system. Thison-line two-dimensional system performs analysis based on thegradient set-up in one and two dimensions.Gradient pumps ×2, single pumps ×2, autosampler, trap column valve, ion exchange column valve ×2, controlsoftware, PC, ion exchange column, analytical column, trap column(*)
* Single pump is installed in "Mieux"
• Optional functions available for Phosphoric Peptide Analysisin each systems of Mieux-I, II, IV, and V.
Top of this page

* User-friendly dedicated software
Top of this page

* Pumping flow schematic
Top of this page

* Various Columns
Various column packing, Nano-LC Trap column,Nano-LC capillary column, Micro, semi-micro, conventional,preperative isolation column
Nano-LC capillary column
Size numberColumn size
2-*0.2mm I.D × *mmL
1.5-*0.15mm I.D × *mmL
1-*0.1mm I.D × *mmL
1-* 0.75-*0.075mm I.D × *mmL

Nano-LC trap column
Size numberColumn size
0.5-10.5mm I.D × 1mmL
0.8-30.8mm I.D × 3mmL
* Same price regardless of size Please ask the typeof column packing and size which you require.
Top of this page

Mieux Series
Mieux
Gradient Nano Pump
Remarks
Auto injection system : single pump included
Manual injection system : single pump not included (gradient pumponly)
Mieux AS
Auto Sampler
Mieux AP
Single Nano Pump
Mieux SP
MALDI Spotter
Nano Micro-Fraction Collector
Top of this page

Mieux Spotter System For MALDI-TOFMS

Example:
1504 spottings on target plate of Applied Bio 4800
By connecting with Mieux,this system enables stable spotting at nL level.

Continuous dispensing to multiple plates
  • Mixed operation of various mfr’s MALDI plates and Microplatesis possible
Simultaneous automatic addition of matrix solution
  • Sample eluate and matrix added simultaneously from the needletip by using the dedicated nano pump (Mieux AP)
  • Plate is not damaged by spotting because a non-contact needleis used
  • Spotting of sample solution is possible at 100 nL/min by usinga dedicated needle
Operation control by dedicated software
  • Integrated control of the SP system together with the MieuxNano LC system
  • Dispensing time can be set freely, starting from 5 seconds
  • Dispensing is possible using an external signal from thedetector
  • Automatic dispensing time calculation function based on theentered analytical time and number of dispensing steps
Configuration Mieux SP-I Mieux-I system, Mieux SP, Mieux AP
Mieux SP-II Mieux-II system, Mieux SP, Mieux AP
Mieux SP-III Mieux-II system, Mieux SP, Mieux AP Mieux-IIIsystem, Mieux SP, Mieux AP
Mieux SP-IV Mieux-IV system, Mieux SP, Mieux AP
Mieux SP-V Mieux-V system, Mieux SP, MieuxAP
Top of this page

* Specifications
Nano gradient pump(Mieux)
Pumping typeOne high-pressure double syringe pumpingsystem installed
One high-pressure single syringe pumping system installed
Syringe volume220uL
Operation controlwith PC operating dedicated software
CommunicationRS-232C
Flow rate rangeHigh-pressure double syringe pumping type
1 nL/min to 200,000 nL/min in 1 nL step (Gradient 50 nL/min to 1000nL/min)
High-pressure single syringe pumping type
1 nL/min to 200,000 nL/min in 1 nL step
Working pressure0.0 to 20.0MPa
Pressure indication0.0 to 50.0MPa in the 0.1 MPa step
FunctionsAuto flush, auto refill, auto drain
Backside terminalRS-232C, external program start terminal,pressure output (2-ch)
Power supplyAC100V to 240V
SizeW300 × H210 × D500mm
Power consumptionMax 200 VA
Nano pump (MieuxAP)
Pumping typeHigh-pressure syringe pumping system
Syringe volume220uL
Operation controlwith PC operating dedicated software
CommunicationRS-232C
Flow range1 nL/min to 100,000 nL/min in 1 nL step
Working pressure0.0 to 15.0Mpa
Pressure indication0.0 to 50.0MPa in 0.1 MPa step
FunctionsAuto flush, auto refill, auto drain
Backside terminalRS-232C, external program start terminal,pressure output
Power supplyAC100V to 240V
SizeW140 × H160 × D320mm
Power consumptionMax 150 VA
Auto injector (Mieux AS) (standardspecifications)
Sample injection methodFull loop, partial loop, micro pickup
Sample injection rate0.1 to 100uL
Sample rack48 vial containers, 96 plates (Low,High), 384(Low)
Injection accuracyFull loop RSD≦0.3
Partial loop RSD≦0.5%(>5μL)
Micro pickup RSD≦1.0%(>5μL)
(*For the micro specifications, contact us separately. )
Operation controlWith PC operating dedicated software or fromthe keypad on the main body
CommunicationRS-232C
Cooling functionMin 4 deg.C (room temperature -16 deg. C)
Power supplyAC115V(50/60Hz), AC230V(50/60Hz)
SizeW280 × H400 × D440mm
Power consumptionMax. 250VA
*Descriptions in the catalog are subject tochange without notice.
Nano HPLC fraction collector (MieuxSP)
Applicable plateMALDI PlateApplied Biosystems/MDS SCIEX Max 8 plates
Bruker Daltonics Max 4 plates
Waters/Micromass Max 4 plates
Microplate96 well plate(Low, High), 384 well plate(Low)
Spotting methodContact or non-contact spotting,
Matrix mixed spotting without needle contact
(Note: Matrix fluid feed pump is optional.)
ProbeTwo-layer (PTFE and SUS) structure
(Sample is center and the matrix solution eluting from the outside)
Allowable dispensing flow range100nL/min. ~
Matrix flow rate range100nL/min. ~
Spotting modeContinuous mode (continuous spotting every fixed giveninterval)
Continuous spotting by external pulse signal
Needle CleaningAutomatic needle cleaning by washingsolvent
Waste solution port provided
Spotting directionStraight, zigzagging
Operation controlPC operating dedicated software
CommunicationRS-232C
Power supplyAC100 to AC240
SizeW500 × H330 × D490mm
WeightApprox. 39 kg
(Note: Matrix fluid feedpump is optional.)

上一篇:煤层瓦斯突出预测仪资料 下一篇:盘式麦芽粉碎机资料
热线电话 在线询价
提示

仪表网采购电话