技术规范

Article number

6ES7131-4BB01-0AA0

6ES7131-4BB01-0AB0

6ES7131-4BD01-0AA0

6ES7131-4BD01-0AB0

6ES7131-4BD51-0AA0

6ES7131-4BF00-0AA0


ET200S,    EL-MOD., 2DI ST, DC 24V, 5PCS.

ET200S,    EL-MOD., 2DI HF, DC 24V, 5PCS.

ET200S,    EL-MOD., 4DI ST., DC 24V, 5PCS.

ET200S,    EL-MOD., 4DI HF, DC 24V, 5PC.

ET200S,    EL-MOD., 4DI HF, DC 24V, 5PCS.

ET200S,    ELEKTRONIKMODULE, 8DI DC 24V

Supply voltage







Rated value (DC)







  • ● 24 V DC

Yes; From power module

Yes; From power module

Yes; From power module

Yes; From power module

Yes; From power module

Yes

permissible range, lower limit (DC)

20.4 V

20.4 V

20.4 V

20.4 V

20.4 V

20.4 V

permissible range, upper limit (DC)

28.8 V

28.8 V

28.8 V

28.8 V

28.8 V

28.8 V

Reverse polarity protection

Yes

Yes

Yes

Yes

Yes

Yes

Input current







from supply voltage L+, max.

Dependent on encoder

Dependent on encoder

Dependent on encoder

Dependent on encoder

Dependent on encoder

Dependent on encoder

from backplane bus 3.3 V DC, max.

10 mA

10 mA

10 mA

10 mA


10 mA

Encoder supply







Number of outputs






0; no encoder supply

Type of output voltage

min. L+ (-0.5 V), under load

min. L+ (-0.5 V), under load

min. L+ (-0.5 V), under load

min. L+ (-0.5 V), under load

max. M +0.5 V, under load


Short-circuit protection


Yes; Electronic


Yes; Electronic



Output current







  • ● Rated        value

500 mA

500 mA

500 mA

500 mA

500 mA


  • ●        permissible range, lower limit

0 mA

0 mA

0 mA

0 mA

0 mA


  • ●        permissible range, upper limit

500 mA

500 mA

500 mA

500 mA

500 mA


Power loss







Power loss, typ.

0.4 W

0.4 W

0.7 W

0.7 W

0.7 W

1.2 W

Address space per module







  • ● with        packing

2 bit

2 bit

4 bit

4 bit

4 bit


  • ● without        packing

1 byte

1 byte

1 byte

1 byte

1 byte

1 byte

Digital inputs







Number of digital inputs

2

2

4

4

4

8

Input characteristic curve in accordance with IEC   61131, type 1

Yes

Yes

Yes

Yes

Yes

Yes; 2-wire sensors connectable

Number of simultaneously controllable inputs







  • ● Number of        simultaneously controllable inputs






8

Input voltage







  • ● Type of        input voltage

DC

DC

DC

DC

DC

DC

  • ● Rated        value (DC)

24 V

24 V

24 V

24 V

24 V

24 V

  • ● for signal        "0"

-30 to +5V

-30 to +5V

-30 to +5V

-30 to +5V

-5 to +30V

-30 to +5V

  • ● for        signal "1"

+15 to +30V

+11 to +30V

+15 to +30V

+11 to +30V

-15 to -30 V

+15 to +30V

Input current







  • ● for        signal "1", typ.

7 mA; at 24 V

8 mA

7 mA; at 24 V

8 mA

7 mA; at 24 V

5 mA

Input delay (for rated value of input voltage)







for standard inputs







  • —        parameterizable

No

Yes; 0.1 / 0.5 / 3 / 15 ms

No

Yes; 0.1 / 0.5 / 3 / 15 ms

No

No

  • — at        "0" to "1", min.

2 ms; typically 3 ms

0.05 / 0.4 / 2.7 / 14.85

2 ms; typically 3 ms

0.05 / 0.4 / 2.7 / 14.85

2 ms; typically 3 ms

2 ms

  • — at        "0" to "1", max.

4.5 ms

0,15 / 0,6 / 3,3 / 15,15

4.5 ms

0,15 / 0,6 / 3,3 / 15,15

4.5 ms

4.5 ms

  • — at        "1" to "0", min.

2 ms; typically 3 ms

0.05 / 0.4 / 2.7 / 14.85

2 ms; typically 3 ms

0.05 / 0.4 / 2.7 / 14.85

2 ms; typically 3 ms

2 ms

  • — at        "1" to "0", max.

4.5 ms

0,15 / 0,6 / 3,3 / 15,15

4.5 ms

0,15 / 0,6 / 3,3 / 15,15

4.5 ms

4.5 ms

Cable length







  • ● shielded,        max.

1 000 m

1 000 m

1 000 m

1 000 m

1 000 m

1 000 m

  • ●        unshielded, max.

600 m

600 m

600 m

600 m

600 m

600 m

Encoder







Connectable encoders







  • ● 2-wire        sensor

Yes

Yes

Yes

Yes

Yes

Yes

  • —        permissible quiescent current (2-wire sensor), max.

1.5 mA

1.5 mA

1.5 mA

1.5 mA

1.5 mA

1.5 mA

Isochronous mode







Isochronous operation (application synchronized up to   terminal)






Yes; TWE = 3000 us

Interrupts/diagnostics/status information







Diagnostic functions

No

Yes

No

Yes

No

No

Alarms







  • ● Hardware        interrupt


Yes; Parameterizable





Diagnostic messages







  • ●        Short-circuit


Yes; Short-circuit of outputs to ground; module by   module


Yes; Short-circuit of outputs to ground; module by   module



Diagnostics indication LED







  • ● Group        error SF (red)

No

Yes

No

Yes

No


  • ● Status        indicator digital input (green)

Yes; per channel

Yes; per channel

Yes; per channel

Yes; per channel

Yes; per channel

Yes

Parameter







Remark

1 byte

3 byte

1 byte

3 byte

1 byte

3-byte parameter (not accessible for the user)

Diagnostics short-circuit


Disable / enable


Disable / enable



Potential separation







Potential separation digital inputs







  • ● between        the channels

No

No

No

No

No

No

  • ● between        the channels and backplane bus

Yes

Yes

Yes

Yes

Yes

Yes

Permissible potential difference







between different circuits

75 V DC/60 V AC

75 V DC/60 V AC

75 V DC/60 V AC

75 V DC/60 V AC

75 V DC/60 V AC

75 V DC/60 V AC

Isolation







Isolation tested with

500 V DC

500 V DC

500 V DC

500 V DC

500 V DC

500 V DC

Dimensions







Width

15 mm

15 mm

15 mm

15 mm

15 mm

15 mm

Height

81 mm

81 mm

81 mm

81 mm

81 mm

81 mm

Depth

52 mm

52 mm

52 mm

52 mm

52 mm

52 mm

Weights







Weight, approx.

35 g

35 g

35 g

35 g

35 g

35 g

 

Article number

6ES7131-4CD02-0AB0

6ES7131-4EB00-0AB0

6ES7131-4FB00-0AB0

6ES7131-4RD02-0AB0

6ES7131-4BF50-0AA0


ET200S,    EL-MOD., 4DI, UC 24-48V, 5 PCS

ET200S,    EL-MOD., 2DI, AC 120V, 5PCS.

ET200S,    EL-MOD., 2DI, AC 230V, 5PCS.

ET200S,    EL-MOD., 4DI DC 24V NAMUR

ET 200S, 8 DI    Source Input DC24V

Supply voltage






Rated value (DC)






  • ● 24 V DC

Yes; From power module



Yes

Yes; From power module

permissible range, lower limit (DC)

24 V



20.4 V

20.4 V

permissible range, upper limit (DC)

48 V



28.8 V

28.8 V

Rated value (AC)






  • ● 24 V AC

Yes





  • ● 120 V AC


Yes; From power module




  • ● 230 V AC



Yes



permissible range, lower limit (AC)

24 V

102 V

192 V



permissible range, upper limit (AC)

48 V

144 V

264 V



Reverse polarity protection

Yes; AC or DC automatic




Yes

Input current






from supply voltage L+, max.

Dependent on encoder




Dependent on encoder

from supply voltage L1, max.


Dependent on encoder

Dependent on encoder



from backplane bus 3.3 V DC, max.

10 mA

6 mA

6 mA



Encoder supply






Number of outputs




1


Type of output voltage

min. L+ (-0.5 V), under load



min. 8.2 V, loaded


Short-circuit protection

Yes; per module



Yes; Electronic


Output current






  • ● Rated        value

500 mA



45 mA


  • ●        permissible range, lower limit

0 mA





  • ●        permissible range, upper limit

500 mA





Power loss






Power loss, typ.

0.7 W

0.5 W

0.7 W

1.6 W

1.2 W

Address space per module






  • ● with        packing

4 bit

2 bit

2 bit

4 bit


  • ● without        packing

1 byte

1 byte

1 byte

1 byte


Digital inputs






Number of digital inputs

4

2

2

4

8

Number of NAMUR inputs




4


Parallel switching of inputs




No


Input characteristic curve in accordance with IEC   61131, type 1

Yes

Yes

Yes


Yes

Number of simultaneously controllable inputs






  • ● Number of        simultaneously controllable inputs




4


Input voltage






  • ● Type of        input voltage

AC/DC

AC

AC

DC

DC

  • ● Rated        value (DC)





24 V

  • ● Rated        value (AC)


120 V; 47 ... 63 Hz

230 V; 47 ... 63 Hz



  • ● Rated        value (UC)

24 V





  • ● for        signal "0"

-6 to +6 V DC/ 0 to 5 V AC

0V AC to 20V AC

0V AC to 40V AC


-5 to +30V

  • ● for        signal "1"

-15 V DC to -57.6 V DC; 15 V DC to 57.6 V DC; 15 V AC   to 48 V AC

79 to 132 V AC

164V AC to 264V AC


-15 to -30 V

Input current






  • ● for        signal "1", typ.

10 mA; 4 to 10 mA

3 mA; 3 to 9 mA

5 mA; 5 to 15mA


6 mA; at 24 V

for 10 k switched contact






  • — for        signal "0"




0.35 to 1.2 mA


  • — for        signal "1"




2.1 to 7 mA


for unswitched contact






  • — for        signal "0", max. (permissible quiescent current)




0.5 mA


  • — for        signal "1"




typ. 8 mA


for NAMUR encoders






  • — for        signal "0"




0.35 to 1.2 mA


  • — for signal        "1"




2.1 to 7 mA


Input delay (for rated value of input voltage)






for standard inputs






  • —        parameterizable





No

  • — at        "0" to "1", min.


15 ms

15 ms


2 ms

  • — at        "0" to "1", max.

15 ms



4.6 µs

4.5 ms

  • — at        "1" to "0", min.


25 ms

45 ms


2 ms

  • — at        "1" to "0", max.

15 ms



4.6 µs

4.5 ms

Encoder connection






  • ● Fixed        current limitation for wire-break monitoring, min.

18 kΩ;   Rated voltage 24 V (15 V to 35 V); rated voltage 48 V (30 V to 60 V): 39   kohms





Cable length






  • ● shielded,        max.

1 000 m

1 000 m

1 000 m

200 m

1 000 m

  • ●        unshielded, max.

600 m

600 m

600 m


600 m

Encoder






Connectable encoders






  • ● 2-wire        sensor

Yes

No

No


Yes

  • —        permissible quiescent current (2-wire sensor), max.

2 mA; (0.5 to 2 mA), a minimum load current is   necessary for wire break diagnostics.

1 mA

2 mA


1.5 mA

Isochronous mode






Isochronous operation (application synchronized up to   terminal)

Yes

No

No


Yes

Interrupts/diagnostics/status information






Diagnostic functions

Yes; Parameterizable

No

No

Yes; Diagnostic alarm

No

Alarms






  • ●        Diagnostic alarm




Yes; can be set


  • ● Hardware        interrupt




No


Diagnostic messages






  • ●        Diagnostic information readable




Yes


  • ●        Wire-break

Yes



Yes


  • ●        Short-circuit


No

No



Diagnostics indication LED






  • ● Group        error SF (red)

Yes



Yes

No

  • ● Status        indicator digital input (green)

Yes; per channel

Yes; per channel

Yes; per channel

Yes; per channel

Yes; per channel

Parameter






Remark


3 byte

3 byte

12 byte

3 byte

Potential separation






Potential separation digital inputs






  • ● between        the channels

No

No

No

No

No

  • ● between        the channels and backplane bus

Yes

Yes

Yes

Yes

Yes

  • ● Between        the channels and load voltage L+




Yes


Permissible potential difference






between different circuits

75 V DC/60 V AC



75 V DC/60 V AC

75 V DC/60 V AC

between M internally and the inputs


1500 V AC

1500 V AC



Isolation






Isolation tested with

2500 V DC

2500 V DC

4 000 V DC

500 V DC

500 V DC

Dimensions






Width

15 mm

15 mm

15 mm

15 mm

15 mm

Height

81 mm

81 mm

81 mm

81 mm

81 mm

Depth

52 mm

52 mm

52 mm

52 mm

52 mm

Weights






Weight, approx.

35 g

31 g

31 g

35 g

35 g