能够测量60KV/30KV有效值高频电压信号的高压探头,脉冲测量达80KV.

详细介绍

HV-P60A

image.png

HV-P60A


High-voltage Probe HV-P60A

image.png

HV-P60A

High-voltage waveforms of up to DC 60 kV, pulse 80 kV measured by oscilloscope

Wide bandwidth, DC to 50 MHz

Maintenance-free, due to use of silicon rubber - guarantees stable withstand voltage

Specifications

Maximum input voltage

DC 60 kV or AC peak*
Single-shot pulse of 80 kV, standard pulse wave

Bandwidth

DC to 50 MHz, within -3 dB

Rise time

7 ns or less (for probes only)

Input RC

1,000 MW ±5% //5 pF ±2 pF

Attenuation

2000:1 ±5%

Cable length

Approx. 4 m

Connector

BNC type

Used for

Oscilloscope with input RC: 1 MW, 10 to 40 pF

Weight

Approx. 3.2 kg (including accessories)

Accessories

Matching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bag

Options

High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60A/60 and the HV-P30A/30. It is attached by turning the probe bracket upside down (for HV-P60A/HV-P60/HV-P30A/HV-P30).

* The P-P voltage drops if the CW is 100 kHz or greater.



This is a passive probe that measures high-voltage waveforms by connecting to an oscilloscope, and has the following characteristics: the bandwidth is DC to 50 MHz, the maximum input is DC 60 kV, and the attenuation is 2000:1.

Characteristic curve

image.png


Maximum Input Voltage and Frequency (Sine Wave) [HV-P60A]



High-voltage Probe HV-P30A

HV-P30A
HV-P30A

High-voltage waveforms of up to DC 30 kV, pulse 40 kV measured by oscilloscope


Wide bandwidth, DC to 50 MHz


Maintenance-free, due to use of silicon rubber - guarantees stable withstand voltage

Specifications

Maximum input voltage

DC 30 kV or DC + AC peak*
Single-shot pulse of 40 kV, repetitive signal

Bandwidth

DC to 50 MHz, within -3dB

Rise time

7 ns or less

Input RC

100 MW ±5% //7 pF or less

Attenuation

1000:1 ±5%

Cable length

Approx. 3 m

Connector

BNC type

Used for

Oscilloscope with input RC: 1 MW, 10 to 40 pF

Weight

Approx. 2.5 kg (including accessories)

Accessories

Matching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bag

Options

High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60A/60 and the HV-P30A/30. It is attached by turning the probe bracket upside down (for HV-P60A/HV-P60/HV-P30A/HV-P30).

* The P-P voltage drops if the CW is 100 kHz or greater.


This is a passive probe that measures high-voltage waveforms by connecting to an oscilloscope, and has the following characteristics: the bandwidth is DC to 50 MHz, the maximum input is DC 30 kV, and the attenuation is 1000:1.


Characteristic curve
Maximum Input Voltage and Frequency (Sine Wave) [HV-P30]

Maximum Input Voltage and Frequency (Sine Wave) [HV-P30A]



Dimensions
Appearance