Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules - Data Sheet The 86100D DCA-X performs precision measurements on high-speed digital designs from 50Mb/s to more than 80Gb/s. 产品资料 2013-09-26 | PDF 549 KB 语言 - English | 2013-09-26 | PDF 549 KB
- 한국어 | 2012-01-27 | PDF 956 KB
|
Time Domain Reflectometry Theory - Application Note When compared to other measurement techniques, time domain reflectometry provides a more intuitive and direct look at the DUT's characteristics. 应用说明 2013-05-31 | PDF 1.40 MB 语言 - English | 2013-05-31 | PDF 1.40 MB
- 日本語 | 2000-03-01 | PDF 1.42 MB
|
DCA Probes and Accessories - Technical Overview See recommended DCA probes and accessories for sampling oscilloscopes. 技术总览 2013-05-31 | PDF 1.39 MB |
Jitter Measurements on Long Patterns Using 86100DU-401 Advanced Waveform Analysis - Application Note To overcome pattern length limitations found in many of today’s jitter analysis tools, Agilent developed a Microsoft Office Excel-based application called 86100DU Option 401 Advanced Waveform Analysis 应用说明 2013-02-21 | PDF 3.47 MB |
86100A/B/C/D Infiniium DCA Programmer's Guide 86100A/B/C/D Infiniium DCA Programmer's Guide 编程和语法指南 2013-01-01 | PDF 3.23 MB |
探头资源中心 帮助文件 2012-09-03 | |
Infiniium DCA-X 86100D Wide-Bandwidth Oscilloscope Mainframe and Modules The 86100D DCA-X is the premier solution for accurate and precise measurements on high-speed digital designs from 50 Mb/s to over 80 Gb/s. 手册 2012-07-20 | PDF 2.69 MB |
86100D DCA-X High-Performance Sampling Oscilloscopes Video This 5 minute video provides an overview of the Agilent 86100D DCA-X wide-bandwidth oscilloscope. 基本演示 2012-04-30 | |
SATA II Drive TX/RX Testing & Cable SI Testing Using the 86100C DCA-J (PN 86100-8) Due to the inherent limitations of parallel technology, SATA is expected to replace parallel ATA everywhere, and expand the use of ATA-based technology in the entry server and network storage market segments. 应用说明 2012-01-31 | PDF 2.73 MB |
PCI Express Design and Test - From Electrical to Protocol Agilent's PCI EXPRESS® brochure will explain basic differences between Gen1, Gen2, and Gen3 as well as the full breadth of Agilent's PCIe solutions. 手册 2012-01-17 | PDF 1.26 MB |
Techniques to Reduce Manufacturing Cost-of-Test of Optical Transmitters Pressures to reduce costs as data rates rise means manufacturing engineering managers and their engineers must be more creative in how to reduce costs before their competitors do. 应用说明 2011-12-22 | PDF 1.20 MB 语言 - English | 2011-12-22 | PDF 1.20 MB
- 日本語 | 2012-05-31 | PDF 1.21 MB
|
Techniques to Reduce Manufacturing Cost-of-Test of Optical Transmitters, Flex DCA Interface Agilent continues innovating test methodologies to assist manufacturing engineers in meeting or beating cost-of-test reduction goals. 应用说明 2011-12-22 | PDF 1.10 MB 语言 - English | 2011-12-22 | PDF 1.10 MB
- 日本語 | 2012-05-31 | PDF 1.31 MB
|
Lowest Cost of Optical Transceiver Test Explore major cost of test reduction ideas using the Eye Mask Hit Ratio Technique and the Auto Mask Margin function. Achieve dramatic efficiency improvement in optical transmitter eye-mask testing. 产品展示 2011-11-01 | WMF 18.87 MB 语言 - English | 2011-11-01 | WMF 18.87 MB
- 中文(繁體) | 2011-11-21 | WMF 20.52 MB
|
N1010A FlexDCA Virtual Device Demonstration N1010A FlexDCA Virtual Device Demonstration Video This 3 minute video shows how to help sell high-speed semiconductors using the N1010A FlexDCA. 产品展示 2011-11-01 | WMF 9.05 MB 语言 - English | 2011-11-01 | WMF 9.05 MB
- 中文(繁體) | 2011-11-01 | WMF 9.05 MB
|
De-embedding demo using InfiniiSim-DCA This 7 minute video documents a de-embedding measurement using InfiniiSim-DCA for the 86100C DCA-J 视频演示 2011-11-01 | WMF 15.38 MB |
Agilent 86100D DCA-X 系列采样示波器 The 86100D DCA-X is the premier solution for accurate and precise measurements on high-speed digital designs from 50 Mb/s to over 80 Gb/s. 手册 2011-09-30 | PDF 2.59 MB |
Techniques for Higher Accuracy Optical Measurements Learn techniques for high accuracy optical measurements using System Impulse Response Correction 应用说明 2011-09-21 | PDF 6.06 MB 语言 - English | 2011-09-21 | PDF 6.06 MB
- 日本語 | 2012-01-26 | PDF 2.89 MB
|
Probing High-Speed Signals with the 86100 Series of Wide-Bandwidth Sampling Oscilloscopes (86100-6) Product Note 86100-6 discusses three important measurement accessories that help make probe-based measurements both simple and accurate for the Agilent 86100 Wide-Bandwidth Oscilloscope. 应用说明 2011-07-28 | PDF 651 KB 语言 - English | 2011-07-28 | PDF 651 KB
- 日本語 | 2007-04-10 | PDF 578 KB
|
Solutions for S-Parameter and Time Domain Characterization Learn about complete channel verification, done simply, with Agilent's 86100C-202 Enhanced Impedance and S-Parameter Software. 资料 2011-07-28 | PDF 159 KB |
86100D - Parallel Testing of Optical Transceivers This video will show that testing optical transceivers in parallel is an important approach to reducing the cost of test and can dramatically reduce the amount of equipment required to build a high volume productions line. 视频演示 2011-07-26 | |
86100D - Lowest Cost of Optical Transceiver Test Explore major cost of test reduction ideas using the Eye Mask Hit Ratio Technique and the Auto Mask Margin function. Achieve dramatic efficiency improvement in optical transmitter eye-mask testing. 视频演示 2011-05-05 | |
86100C DCA-J示波器模式 86100C DCA-J示波器模式 资料 2011-04-29 | |
86100 Infiniium DCA Online Help Archive The Infiniium DCA Online Help contains information you need to use your DCA. This includes theory of operation, step-by-step procedures for many common tasks, a complete glossary and much more. 帮助文件 2011-04-20 | |
86100D DCA-X Overview This 5 minute video provides an overview of the 86100D DCA-X wide-bandwidth oscilloscope. 产品展示 2010-06-16 | WMF 12.74 MB |
DCA Selection and Configuration Guide 选型指南 2010-06-09 | |