JFEYH10KV高压电机引接线-电气设备用电缆
JFEYH10KV高压电机引接线-电气设备用电缆
JFEYH10KV高压电机引接线-电气设备用电缆
JFEYH10KV高压电机引接线-电气设备用电缆
JFEYH10KV高压电机引接线-电气设备用电缆

JFEYH10KV高压电机引接线-电气设备用电缆

参考价: 面议

具体成交价以合同协议为准
2017-07-07 15:23:14
1334
属性:
产地:国产;防护等级:IP40;护套材质:橡胶;加工定制:是;绝缘厚度:1.5;外表材质:乙丙橡胶;线芯材质:紫铜线;芯数:1;
>
产品属性
产地
国产
防护等级
IP40
护套材质
橡胶
加工定制
绝缘厚度
1.5
外表材质
乙丙橡胶
线芯材质
紫铜线
芯数
1
关闭
江苏春晨电缆有限公司

江苏春晨电缆有限公司

免费会员
收藏

组合推荐相似产品

产品简介

JFEYH10KV高压电机引接线
1、工作温度+90℃;
2、额定电压为10000V;
3、导体采用196/0.40的镀锡铜丝,成品参考外径为22mm,
4、电缆敷设时允许弯曲半径应不小于电缆外径的4倍

详细介绍

江苏春晨电缆有限公司:https://www.ybzhan.cn/st82365/

JFEYH10KV高压电机引接线
1、工作温度+90℃;
2、额定电压为10000V;
3、导体采用196/0.40的镀锡铜丝,成品参考外径为22mm,
4、电缆敷设时允许弯曲半径应不小于电缆外径的4倍,

We believe that heating cable is not too familiar, but warm everybody should know, now every family cannot do without the winter is warm, the following Xiaobian take you to understand what is the heating cable.

发热电缆,是制成电缆结构,以电力为能源,利用合金电阻丝进行通电发热,来达到采暖或者保温的效果。通常有单导和双导之分,称为发热电缆。

Heating cable, is made of cable structure, with electric power as the energy, the use of alloy resistance wire heating, to achieve the effect of heating or thermal insulation. Usually has a single guide and double guide, known as the heating cable.

发热电缆供暖之所以称之为冬季的采暖方式,不仅仅在于它的经济、安全、方便、高品质,而在于它将人作为生活的主体,突出了舒适、健康、环保这三大现代生活的主题;高度的人性化设计,简单、灵活的控制方式,给使用者带来*的方便;隐蔽于地面下的系统结构,zui大限度地节省了室内空间。

Heating is called the most ideal winter heating mode, not only lies in its economic, safe, convenient, high quality, and that it will be as the subject of life, comfort, health, environmental protection has highlighted the three modern life theme; humanized design height, the control mode is simple and flexible. Bring great convenience to the users; system structure hidden in the ground, to maximize indoor space saving.

发热电缆供暖系统主要是靠远红外线辐射传热(占总传热量的60%以上),其辐射原理与太阳辐射原理相同。热量的传递方式分为对流、传导、辐射三种形式,辐射热是人体感觉zui舒适的传热方式,给人以阳光般温暖的感觉,没有空气流动、没有燥热感,人们可根据自身需要,设定自己的室内温度,不受室外温度的影响,不受季节的限制,室内始终保持温暖如春的感觉。

Heating cable heating system mainly by far infrared radiation heat transfer (accounting for more than 60% of total heat transfer), the principle of radiation and the same principle of solar radiation. The heat transfer mode is divided into three forms: conduction, convection, radiation, radiation heat transfer is the human body most comfortable, give a person with warm sunshine feeling, no air, no feeling hot, people according to their own needs, set the most suitable indoor temperature and outdoor temperature is not affected that is not restricted by seasons, indoor always keep warm as spring feeling.

安装发热电缆时这10点你注意过吗?

Did you notice the 10 points when installing the heating cable?

1、各种材料的材质规格,品种型号必须符合设计及相应规范要求,必须相应证件齐全;

1, a variety of materials, material specifications, varieties must meet the requirements of the design and the corresponding norms, must be the appropriate documents;

2、防止发热电缆被压入绝热材料中,影响发热电缆的寿命,采用钢丝网或金属固定带既能够防止发热电缆压入绝热材料。

2, to prevent the heating cable is pressed into the thermal insulation material, the influence of heating cable life, the use of steel wire mesh or metal fixed with both to prevent the heating cable into the insulation material.

3、管内穿限在确认发热电缆或电热膜铺设无误后进行,在穿线前必须将暗盒内清扫干净,做到导线分色正确,余量适量;

3, the tube wear limit in confirmation of heating cable or electric heating film laying correct, before threading in a cassette must be clean, do the right amount of wire separation, margin;

4、温控器安装应做到横平竖直,标准准确,紧贴墙面,固定牢靠,符合电气分项工程验收规范;

4, temperature control device installation should be horizontal and vertical, standard accurate, close to the wall, solid, consistent with the electrical breakdown of the project acceptance specifications;

5、所有施工人员必须穿软底鞋,导管密封后清理整个作业面;

5, all construction personnel must wear soft bottom shoes, after sealing the pipe to clean up the entire operating surface;

6、地板辐射供暖系统的安装工程,不宜与其它施工作业同时交叉进行;

6, floor radiant heating system installation works, and other construction work should not be carried out at the same time cross;

7、混凝土填充层的浇注和养护过程中,不得进入践踏,浇注混凝土时,要采取保护措施,不可以直接脚踏、车碾发热电缆或电热膜发热区;填充层养护期满后,不得在地面上运行重载或放置高温物体;

7, concrete pouring and curing process of filling layer, are not allowed to enter the trampling, pouring concrete, should take protective measures, can not be directly pedal, car heating cable or electric heating area; the filling layer maintenance period, not on the ground running overload or placed high temperature object;JFEYH10KV高压电机引接线

8、施工完成的电地暖地面严禁大力敲打,冲击。不得在地面上开孔、剔凿或契入热河物体;

Electric heating is prohibited, to complete the construction of the 8 floor banging on the impact. No holes in the ground, chisel or deed into Rehe objects;

9、全居室等电位连接,保证人身安全。

9, the whole room and other electric potential connection, to ensure personal safety.

10、温控器探头及铺装并连接好发热电缆保护。

10, temperature controller probe and pavement and connect the heating cable protection.

上一篇:世界上*±1100kV变压器通过型式试验 下一篇:电机引接线环保型电缆相较于其他传统电缆有哪些优势
热线电话 在线询价
提示

仪表网采购电话