品牌
经销商厂商性质
所在地
PL2250系列高能量皮秒锁模Nd:YAG激光器(PL2250 series high energy picosecond mode-locked Nd:YAG lasers)
品牌:EKSPLA
型号:PL2250
采用了单脉冲能量100 mJ,小于30皮秒(20 ps可选)脉冲持续时间,pl2250系列皮秒锁模钕:YAG激光器在高脉冲能量皮秒激光器建立了新标准。创新和成本效益的设计,可以提高激光的可靠性,同时降低运行和维护成本。
Features
Applications
PL2250 series lasers set a new standard in high pulse energy picosecond lasers. Their innovative and cost-effective design improves laser reliability and reduces running and maintenance costs.
Innovative design
The heart of the system is a diode pumped solid state (DPSS) master oscillator placed in a hermetically sealed monolithic block. The flashlamp pumped regenerative amplifier is replaced by an innovative diode pumped regenerative amplifier. Diode pumping results in negligible thermal lensing, which allows operation of the regenerative amplifier at variable repetition rates, as well as improved long-term stability and maintenance-free operation.
The optimized multiple-pass power amplifier is flashlamp pumped and is optimized for efficient amplification of pulse while maintaining a near Gaussian beam profile and low wavefront distortion. The output pulse energy can be adjusted in approximately 1% steps, at the same time as pulse-to-pulse energy stability remains less than 0.8% rms at 1064 nm. Angle-tuned KD*P and KDP crystals mounted in thermostabilised ovens are used for second, third and fourth harmonic generation. Harmonics separators ensure the high spectral purity of each harmonic directed to different output ports.
Built-in energy monitors continuously monitor output pulse energy. Data from the energy monitor can be seen on the remote keypad or PC monitor. The laser provides several triggering pulses for synchronization of the customer‘s equipment. The lead or delay of the triggering pulse can be adjusted in 0.25 ns steps from the control pad or PC. Up to 1000 μs lead of triggering pulse is available as a pretrigger option.
Precise pulse energy control, excellent short-term and long-term stability, and up to 50 Hz repetition rate makes PL2250 series lasers an excellent choice for many demanding scientific applications.
Simple and convenient laser control
For customer convenience the laser can be controlled from a user-friendly remote control pad or USB interface. The remote pad allows easy control of all parameters and features a backlit display that is easy to read even while wearing laser safety eyewear. Alternatively, the laser can be controlled from a personal computer with supplied software for a Windows? operating system. LabVIEW? drivers are supplied as well.
Model | PL2250 | PL2251 | PL2251A | PL2251B | PL2251C |
---|---|---|---|---|---|
Pulse energy | |||||
At 1064 nm | 1 mJ | 30 mJ | 50 mJ 2) | 80 mJ 2) | 100 mJ |
At 532 nm 3) | 0.45 mJ | 15 mJ | 25 mJ | 40 mJ | 50 mJ |
At 355 nm 4) | 0.3 mJ | 10 mJ | 15 mJ | 24 mJ | 30 mJ |
At 266 nm 5) | 0.15 mJ | 3 mJ | 7 mJ | 10 mJ | 12 mJ |
At 213 nm 6) | - | 1.5 mJ | 3 mJ | 4.5 mJ | 6 mJ |
Pulse energy stability, (Std. Dev.) 7) | |||||
At 1064 nm | < 0.2 % | < 0.8 % | |||
At 532 nm | < 0.4 % | <1.0 % | |||
At 355 nm | < 0.5 % | < 1.1 % | |||
At 266 nm | < 0.5 % | < 1.2 % | |||
At 213 nm | - | < 2.5 % | |||
Pulse duration (FWHM) 8) | 30 ± 3 ps | ||||
Pulse duration stability 9) | ± 1.0 ps | ||||
Repetition rate | 0-50 Hz | 50 or 10 Hz | 50, 20 or 10 Hz | 20 or 10 Hz | 10 Hz |
Polarization | linear, vertical, > 100:1 | ||||
Pre-pulse contrast | > 200:1 | ||||
Triggering mode | internal/external | ||||
SYNC OUT pulse jitter 10) | < 0.1 ns | ||||
SYNC OUT pulse delay 11) | - 500...50 ns | ||||
Beam divergence 12) | < 1.5 mrad | < 0.6 mrad | < 0.5 mrad | < 0.5 mrad | < 0.5 mrad |
Beam pointing stability 13) | < 10 μrad | < 50 μrad | < 50 μrad | < 50 μrad | < 50 μrad |
Beam diameter 14) | ~2.5 mm | ~ 6 mm | ~ 8 mm | ~10 mm | ~12 mm |
Typical warm-up time | 5 min | 30 min | 30 min | 30 min | 30 min |
Physical characteristics
Model | PL2250 | PL2251 | PL2251A | PL2251B | PL2251C |
---|---|---|---|---|---|
Laser head size (W x L x H) | 453x1024x260 mm | 453x1224x250 mm | |||
Electric cabinet size (W x L x H) | 12 VDC power adapter, 85x170x41 mm | 550x600x550 mm | |||
Umbilical length | 2.5 m |
Operating requirements
Model | PL2250 | PL2251 | PL2251A | PL2251B | PL2251C |
---|---|---|---|---|---|
Water consumption (max 20 °C ) | Air cooled | < 8 l/min | |||
Room temperature | 22 ± 2 °C | ||||
Relative humidity | 20-80 % (non-condensing) | ||||
Power requirements 15) | 110-240 VAC, 50/60 Hz | Single phase, 208 or 230 VAC, 16A, 50/60 Hz | |||
Power 16) | < 0.15 kVA | < 1.5 kVA | < 1.5 kVA | < 2 kVA | < 2.5 kVA |
1) Due to continuous improvement, all specifications are subject to change without notice. Parameters marked typical are not specifications. They are indications of typical performance and will vary with each unit we manufacture. Unless stated otherwise, all specifications are measured at 1064 nm.
2) PL2251A-50 has 40 mJ at 1064 nm, PL2251B-20 has 70 mJ at 1064 nm output energy. Inquire for these energies at other wavelengths.
3) For -SH option. Outputs are not simultaneous. Please inquire for pulse energies at other wavelengths.
4) For -TH option. Outputs are not simultaneous. Please inquire for pulse energies at other wavelengths.
5) For -FH option. Outputs are not simultaneous. Please inquire for pulse energies at other wavelengths.
6) For -FiH option. Outputs are not simultaneous. Please inquire for pulse energies at other wavelengths. FiH option is supplied in separate harmonics unit.
7) Averaged from 300 pulses.
8) Inquire for optional pulse durations in 20 – 90 ps range.
9) Measured over 1 hour period when ambient temperature variation is less than ±1 °C.
10) 10 ps jitter is provided with PRETRIG option.
11) SYNC OUT lead or delay can be adjusted with 0.25 ns steps in specified range.
12) Full angle measured at the 1/e2 point at 1064 nm .
13) RMS value measured from 300 shots.
14) Beam diameter is measured at 1064 nm at the 1/e2 point.
15) Three phase 208 or 380 VAC mains are required for 50 Hz versions.
16) For 10 Hz version.