品牌
代理商厂商性质
深圳市所在地
德国OPTOLOGIC测速仪-电阻测试仪
面议德国OPTOLOGIC测速仪-电阻测试仪
面议德国OPTOLOGIC测速仪-电阻测试仪
面议德国OPTOLOGIC测速仪-电阻测试仪
面议ASP5500-300-A-O-O-O-O德国OPTOLOGIC测速仪-电阻测试仪
面议瑞士E+H变送器PMP75-YD21P29AFGM3-气体压力变送器
面议瑞士E+H压力变送器PMP55-AA22QA1MGJT7JA-气体压力变送器
面议瑞士E+H压力变送器PMP55-AA21RA1KGDTDJA-气体压力变送器
面议瑞士E+H压力变送器PMP55-AA22QA1HGCUPJA-气体压力变送器
面议瑞士E+H压力变送器PMP55-17FV1/0-气体压力变送器
面议瑞士E+H压力变送器PMP55-AA11RA1SGBCXJA-气体压力变送器
面议瑞士E+H压力变送器PMP55-U4Q6/0-气体压力变送器
面议美国*Monroe 平板式静电测量仪
Monroe新产品 平板式离子静电测试仪ME-300,功能同ME-268A,测试范围为±1050 volts,*可以满足离子风机测试使用
300 uses large, high-contrast,alpha/numeric LED displays for easy reading at any vieweing angle, even in highambient lighting conditions. Individual LED’s, provide additional operationstatus during testing and setup. Single-button operation of manual +decay,-decay and balance ensures simple, easy operation. Balance tests record ±peaksand average reading. Each test can be customized in setup for stop trip levelsand test duration. An automated set of tests can be initiated with a singlebutton depress.
Operation and setup can be done via a USBport and PC software in addition to the front panel buttons. Test results canalso be retreived for automatic or manual test.
Real time analysis of ionizers can be donevia the analog output.
美国*Monroe 平板式静电测量仪
1 Measures, displays and stores last testdata, including discharge times, peak offset voltages, and average offsetvoltage.
2 Easiest, most reliable way to checkeffectiveness of all ionization-type static control systems
3 Meets Requirements of ANSI/ESD STM 3.1
4 Removable, cable-connected ioncollecting plate probe permits precise positioning and remote monitoring
5 Separate time and voltage displays fordischarge time test
6 Recorder output for permanent recordsand unattended operation
7 One range measures from 0 to ±1kV
8 SDramatically demonstrates inducedcharges and human body potential
9 AC and battery operation
10Perform long-term balance tests
Features:
? Measures, displays and stores last test
data, including discharge times, peak
offset voltages, and average offset
voltage.
? Easiest, most reliable way to check effectiveness ofall ionization-type static control systems
? Meets Requirements of ANSI/ESD
STM 3.1
? Removable, cable-connected ion
collecting plate probe permits precise
positioning and remote monitoring
? Separate time and voltage displays for discharge timetest
? Recorder output for permanent records and unattended operation
? One range measures from 0 to ±1kV
? Dramatically demonstrates induced charges and humanbody potential
? AC and battery operation
? Perform long-term balance tests
Specifications:
Charger: ±1050 volts, selectable polarity
Fieldmeter:Range: 0 to ±1300 volts on display 0 to ±1800volts analog output1 volt resolution
Accuracy: ±2% of reading ±2V + zero offset
Bandwidth: 6Hz
Analog output: 1/1000 of plate voltage, ±3%
Trip Points: Start Voltage: 1000 volts fixed StopVoltage: 10 to 990 volts in 1V steps
Charge Plate:Size: 6”x6” (15cm x 15cm)
Capacitance: 20pf, ±10%
Plate selfdischarge: Less than 100 volts within 5 minutes(< 60% R.H.)
Timer:Range: 0.1 sec to 999.9 sec Resolution: 0.1 sec Accuracy: 0.1 sec
PowerRequirements: 100 to 220 VAC nominal line voltage;less than 5 Watts.
Battery Life: >8 hours
Dimensions: Approx 6?”W x 8?”D x 6H”
Weight: Approx 5.2 lbs.
PROBES andACCESSORIES
MODLE DEscriptION
300/84 Carry Case