3EH-500Z animal position switch Vibration
面议5EH-900S magnetostrictive level transmitter
面议KERD800HB smart radar level meter
面议8EH-800A series high frequency smart radar level m
面议8EH-800B high-frequency radar level meter
面议8EH-800C high-frequency radar level meter
面议9EH-900A high-frequency radar level meter
面议9EH-900B high-frequency radar level meter
面议9EH-900S high-frequency radar level meter
面议9EH-900SS high-frequency radar level meter explosi
面议High-temperature fluorine plastic cable
面议KSLEX flameproof straight trip electronic actuator
面议9ED-500H metal tube is commonly used in industrial automation and process control of a flow measurement instruments, it has a small pressure loss, detection range (10:1 turndown), easy to use features, it can be used to measure liquid, gas and steam flow, especially suitable for low velocity flow measurement of small flow media. 9ED-500H metal tube with local display and inligent remote type, with the pointer shows the instantaneous flow, cumulative flow, liquid crystal display, upper and lower limit alarm output, accumulated pulse output, the standard two-wire 4-20mA current output and other forms, to provide users with a very broad choice. In addition to the instrument microprocessor MCU with high-quality system to ensure a flow meter place in the excellent performance of various applications. Over the years a variety of fine metal tube flowmeter performance and reliability, and better cost performance by the wide range of petrochemicals, iron and steel, electric power, metallurgy, light industry of all ages.
【Technical Parameters】
Range: Water 2.5 ~ 100000 l / h (20 ℃)
Air (0.1013MPa 20 ℃) ??0.05 ~ 4000 m3 / h
Range Ratio: 10:1 (special type 20:1)
Accuracy: 1.0,1.5,2.5
Working pressure: DN15, DN25, DN50 to PN4.0MPa maximum of 10.0MPa;
DN80, DN100 to a maximum of 6.4MPa PN1.6MPa
Medium temperature: Standard -40 ℃ ~ 300 ℃
Media Viscosity: DN15: η ≤ 5mPa.s (F15.1 ~ F15.3) η ≤ 30mPa.s (F15.4 ~ F15.8)
DN25: η ≤ 250mPa.s
DN50-DN150: η ≤ 300mPa.s
Temperature: LCD type: -40 ℃ ~ 85 ℃ pointer type: -40 ℃ -120 ℃
Connection: flange (or users with implementation of the standards DIN2501 Flange Manufacturing)
Instrument height: 250mm cable interface: M20 * 1.5 Intrinsically Safety: Exia II CT4
LCD: double LCD display, shows the instantaneous flow and total flow.
Power supply: 24VDC two wire 4-20mA or 85 ~ 265VAC 50/60Hz (remote type)
Alarm output: upper or lower instantaneous flow alarm relay output (contact capacity maximum 5mA @ 250VDC) or open collector output (max 100mA @ 30VDC internal impedance 100Ω)
Pulse output: Cumulative pulse output, the minimum interval of one pulse every 10 seconds (AC type) or a pulse every 50 milliseconds.
Measuring tube material: 316L stainless steel (ordinary) or lined with polytetrafluoroethylene (anti-corrosion)