电厂供热蒸汽流量计

电厂供热蒸汽流量计

参考价: 面议

具体成交价以合同协议为准
2023-09-01 10:38:14
281
产品属性
关闭
江苏翔腾仪表有限公司

江苏翔腾仪表有限公司

免费会员
收藏

组合推荐相似产品

产品简介

电厂供热蒸汽流量计是根据卡门(Karman)涡街原理测量过热蒸汽体积流量、标况的体积流量或质量流量的体积流量计。并可作为流量变送器应用于自动化控制系统中。采用*的差动技术,配合隔离、屏蔽、滤波等措施,克服了同类产品抗震性差、小信号数据紊乱等问题,并采用了的传感器封装技术和防护措施,

详细介绍

电厂供热蒸汽流量计是根据卡门(Karman)涡街原理测量过热蒸汽体积流量、标况的体积流量或质量流量的体积流量计。并可作为流量变送器应用于自动化控制系统中。采用*的差动技术,配合隔离、屏蔽、滤波等措施,克服了同类产品抗震性差、小信号数据紊乱等问题,并采用了的传感器封装技术和防护措施,保证了产品的可靠性。产品有基本型和复合型两种型式,基本型测量单量信号;复合型可同时实现温度、压力、流量的测量。每种型式都有整体、分体结构,以适应不同的安装环境。可广泛用于大、中、小型各种管道给排水、工业循环、污水处理,油类及化学试剂以及压缩空气、饱和及过热蒸汽、天然气及各种介质流量的计量。

过热蒸气密度表( Kg/m 3 )
压力温度 t( ℃ )
p /MPa140150160170180190200210220230240
0.201.0701.0421.0160.9920.9690.9470.9260.9060.8870.8680.851
0.301.6221.5781.5371.4991.4631.4281.3961.3651.3361.3081.281
0.40-2.1272.0672.0141.9641.9161.8721.8291.7891.7511.715
0.50--2.6082.5382.4722.4112.3532.2992.2472.1982.152
0.55--2.8822.8032.7292.6612.5962.5352.4782.4242.372
0.60--3.1593.0712.9892.9122.8412.7732.7102.6502.593
0.65---3.3413.2503.1653.0873.0132.9432.8772.815
0.70---3.6143.5143.4213.3343.2533.1173.1053.037
0.75---3.8893.7793.6783.5843.4953.4133.3353.261
0.80----4.0483.9373.8353.7393.6493.5653.486
0.85----4.3184.1984.0873.9843.8873.7973.711
0.90----4.5914.4614.3424.2314.1274.0303.938
1.00----5.1454.9954.8564.7294.6104.4994.395
1.10-----5.5375.3795.2335.0984.9734.855
1.20-----6.0895.9095.7445.5935.4525.321
1.30------6.4486.2636.0935.9365.790
1.40------6.9966.7896.6006.4266.265
1.50------7.5547.3247.1146.9226.744
1.60-------7.8677.6357.4247.229
1.70-------8.4188.1637.9317.719
1.80-------8.9788.6998.4468.214
1.90-------9.5489.2438.9678.715
2.00--------9.7959.4959.222
2.10--------10.3610.039.735
2.20--------10.9310.5710.25
2.30--------11.5111.1210.78
2.40---------11.6811.31
2.50---------12.2511.85
2.60---------12.8312.40
2.70---------13.4112.96
2.80----------13.52
2.90----------14.09
3.00----------14.67
3.10----------15.26
3.20----------15.86
3.30----------16.47
3.40-----------
3.50-----------
4.00-----------









附 录
























续附表二

































过热蒸气密度表( Kg/m 3 )
压力温度 t( ℃ )
p /MPa250260270280290300310320330340350
0.200.8340.8180.8030.7880.7740.7600.7470.7340.7210.7090.698
0.301.2561.2301.2081.1851.1631.1421.1221.1031.0841.0661.049
0.401.6801.6471.6151.5851.5551.5271.5001.4741.4491.4241.401
0.502.1082.0662.0251.9861.9491.9141.8791.8461.8141.7841.754
0.552.3232.2762.2312.1882.1472.1082.0702.0331.9981.9641.931
0.602.5392.4872.4382.3912.3452.3022.2602.2202.1822.1452.109
0.652.7552.6992.6962.5942.5442.4972.4522.4082.3662.3262.287
0.702.9732.9122.8532.7972.7442.6932.6432.5962.5512.5072.465
0.753.1913.1253.0623.0012.9942.8892.8362.7852.7362.6892.643
0.803.4113.3393.2713.2063.1443.0853.0282.9742.9212.8712.822
0.853.6313.5543.4813.4123.3453.2823.2213.1633.1073.0533.001
0.903.8523.7703.6923.6183.5473.4803.4153.3533.2933.2363.181
1.004.2964.2044.1164.0323.9523.8763.8043.7343.6673.6033.541
1.104.7454.6414.5424.4494.3604.2754.1944.1164.0423.9713.902
1.205.1985.0824.9724.8694.7704.6764.5874.5014.4194.3404.265
1.305.6545.5265.4055.2915.1825.0794.9814.8874.7984.7114.629
1.406.1145.9745.8415.7165.5985.4855.3785.2755.1785.0844.994
1.506.5796.4256.2806.1446.0155.8935.7765.6655.5605.4585.361
1.607.0496.8806.7236.5756.4356.3036.1776.0575.9435.8345.729
1.707.5227.3407.1697.0096.8586.7156.5806.4516.3296.2116.099
1.808.0017.8037.6197.4467.2847.1316.9856.8476.7166.5906.470
1.908.4848.2718.0727.8867.7127.5847.3937.2457.1056.9716.843
2.008.9738.7438.5298.3308.1447.9687.8027.6457.4967.3537.217
2.109.4669.2198.9908.7778.5788.3918.2148.0477.8887.7377.593
2.209.9659.7009.4559.2289.0159.9658.6288.4518.2838.1237.970
2.3010.4710.199.9249.6829.4569.2449.0458.8578.6798.5108.349
2.4010.9810.6810.4010.149.8999.6759.4649.2669.0788.8998.730
2.5011.5011.1710.8710.6010.3510.119.8869.6769.4789.2909.112
2.6012.0211.6711.3611.0710.8010.5510.3110.099.8809.6839.495
2.7012.5512.1811.8411.5311.2510.9810.7410.5010.2810.089.880
2.8013.0812.6912.3312.0111.7111.4311.1710.9210.6910.4710.27
2.9013.6213.2112.8312.4812.1711.8711.6011.3411.1010.8710.66
3.0014.1713.7313.3312.9712.6312.3212.0311.7611.5111.2711.05
3.1014.7314.2613.8413.4513.1012.7712.4712.1911.9211.6711.44
3.2015.3014.8014.3513.9413.5713.2312.9112.6212.3412.0811.83
3.3015.8715.3414.8614.4414.0513.6913.3613.0512.7612.4812.23
3.4016.4515.8915.3914.9414.5314.1513.8013.4813.1812.8912.63
3.5017.0416.4415.9115.4415.0114.6114.2513.9113.6013.3013.02
4.00-19.3418.6518.0417.4917.0016.5516.1315.7415.3915.05
电厂供热蒸汽流量计选型:
类型
XT-LUGB
XT-LUW
脉冲输出
现场显示、带4~20mA输出

通径(mm)流量范围(/h)
DN25
DN32
DN40
DN50
DN80
DN100
DN150
Dn200
1~10(液体) 25~60(气体)
1.5~18(液体) 15~150(气体)
2.2~27(液体)  22.6~150(气体)
4~55(液体)   35~350(气体)
9~135(液体) 90~900(气体)
14~200(液体) 140~1400(气体)
32~480(液体)  300~3000(气体)
56~800(液体) 550~5500(气体)
备注:1、蒸汽流量范围请查看表3。
2、DN250~DN600可按客户要求订货。
3、DN300以上口径推荐使用插入式涡街流量计,可定做。

压力等级

P1
P2
P3

1.6MPa
2.5MPa
4.0MPa

法兰材料
B1
B2
不锈钢
碳钢

介质温度
T1
T2
T3
常温
高温
蒸汽

连接方式
L1
L2
法兰卡装式
法兰连接式

供电电源
D1
D2
内部3.6V供电
DC24V供电

精度等级
E1
E2
1.0级
1.5级
XT-LUGB-DN25-P1B1T1L1D2E1型号举例

电厂供热蒸汽流量计安装环境要求:

  1. 尽可能避开强电设备、高频设备、强开关电源设备。仪表的供电电源尽可能与这些设备分离。

  2. 避开高温热源和辐射源的直接影响。若必须安装,须有隔热通风措施。

  3. 避开高湿环境和强腐蚀气体环境。若必须安装,须有通风措施。

  4. 涡街流量仪表应尽量避免安装在振动较强的管道上。若必须安装,须在其上下游2D处加设管道紧固装置,并加防振垫,加强抗振效果。

  5. 仪表安装在室内,安装在室外应注意防水,特别注意在电气接口处应将电缆线弯成U形,避免水顺着电缆线进入放大器壳内。

  6. 仪表安装点周围应该留有较充裕的空间,以便安装接线和定期维护。


上一篇:威力巴流量计产品优点 下一篇:衬氟玻璃转子流量计产品用途
热线电话 在线询价
提示

仪表网采购电话