Face Mask Respiratory Resistance Tester    (GB)

AG-2665Face Mask Respiratory Resistance Tester (GB)

参考价: 面议

具体成交价以合同协议为准
2021-07-16 13:21:58
201
产品属性
关闭
深圳市安规检测设备有限公司

深圳市安规检测设备有限公司

免费会员
收藏

组合推荐相似产品

产品简介

A. Applicable Standards:GB 2626-2019: Respiratory protection—Non-powered air-purifying particle respirator, section 6.5, 6.6GB/T 32610-2016: Technical specification of daily protective mask

详细介绍

A. Applicable Standards:

GB2626-2019: Respiratory protection—Non-powered air-purifying particle respirator,section 6.5, 6.6

GB/T32610-2016: Technical specification of daily protective mask


B. Testing Principles:

1.     Thetester is composed of an air source with an adjustable flow rate, a standardhuman head model, an inspiratory and expiratory circuit system, and a respiratoryresistance measurement system.

2.     Aspecial air path conversion element is adopted to ensure that the inspiratoryand expiratory circuit system are easy to be replaced.

3.     Digitaldisplay of respiratory resistance with zero point correction, accuracycorrection, and over-range alert function.

4.     Astandard flow meter is adopted to ensure flow control accuracy.

5.     Computercontrol and data acquisition system provide real-time detection and output ofpressure control, breathing frequency control, and respiratory resistance testdata.


C. Technical Parameters

1.     FlowRate: (85±1)L/min, 0.1L/min, better than ±2.5%

2.    Head ModelL/M/S (New Standard)

3.     PressureRange: 1500Pa±0.1Pa, better than 1%

4.     DataStorage: 500 Sets

5.     Dimensions:(W×D×H) (600*600*750)mm

6.     Weight:about 35kg

7.     PowerDissipation: 1.3w

8.     AC220/50HZ