免费会员 生产厂家
参考价:
具体成交价以合同协议为准
免费会员 生产厂家
Application | Compressors with direction of rotation essential for function |
Functions | Motor temperature static, Lock-out, Phase sequence, phase failure |
Supply voltage | AC 24-240V |
Permitted ambient temperature | -30...+70°C |
Temperature measuring circuits: Type | 1-2 AMS sensors in series alternative 1-9 PTC sensors acc. to DIN 44081, DIN 44082 in series |
Temperature measuring circuits: R_25, total | <1.8kΩ |
Temperature measuring circuits: R_trip, static | 4.5kΩ ±20% |
Temperature measuring circuits: R_reset | 2.75kΩ ±20% |
Temperature measuring circuits: Max. length connection line | 30m |
Motor voltage | 3 AC 50/60Hz 200-575V ±10% |
Phase monitoring: Phase sequence | Active about 1s after motor start for about 5s |
Phase monitoring: Phase failure | Active about 1s after motor start for about 5s |
Phase monitoring: Inactive | After motor stop for approx. 20s |
Reset delay: Motor temperature static | 5min ±1min |
Reset delay: Incorrect phase sequence | Locked |
Reset delay: Phase failure | Locked |
Resetting the lock or the reset delay | Main reset >5s only possible if there is no error current |
Relay: Mechanical service life | Approx. 1 million switching cycles |
Interface | Diagnose port (DP) |
Protection class acc. To EN 60529 | IP00 |
Connection type | 6.3mm flat plugs |
Housing material | PA glass-fibre-reinforced |
Mounting | Screw mounted |
Dimensions | See dimensions in mm |
Weight | Approx. 200g |
Check base | EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2 |
Approval | UL File No. E75899 cURus |
Supply voltage: 22 A 626 | AC 50/60Hz 115-240V ±10% 3VA |
Supply voltage: 31 A 626 | AC 50/60Hz 24V ±10% 3VA |
Relay: Contact (22 A 626) | AC 240V 2.5A C300 at least AC/DC 24V 20mA |
Relay: Contact (31 A 626) | AC 240V 2.5A C300 at least AC/DC 100mV 0.5mA |
Power consumption | Not suitable |