IWATSU  VOAC7523H/7522H/7520H/7521H 岩崎数字万用表

IWATSU VOAC7523H/7522H/7520H/7521H 岩崎数字万用表

参考价: 面议

具体成交价以合同协议为准
2022-07-16 13:52:31
304
产品属性
关闭
长沙力高捷创仪器有限公司

长沙力高捷创仪器有限公司

免费会员
收藏

组合推荐相似产品

产品简介

Single VOAC7523H/7520H unit, equipped with a 2-channel DC measuring input and dual display, can perform DC voltage measuring that normally requires two units and thus saves installation space and impr......

详细介绍

Full scale, 509999

The highest full-scale count value among 5.5-digit models. (Researched by Iwatsu Test Instruments Corporation in November 2004)


Isolated 2CH input, dual display (VOAC7523H/7520H only)

Two DC measuring inputs are available.
The two channels are isolated from each other. Voltage comparison between two different circuits or potential difference measuring between parts within the same circuit can be easily performed. A single VOAC7523H/7520H unit can perform DC voltage measuring that normally requires two units, and thus saves installation space and improves measuring speed.
The VOAC7523H/7520H also has dual display functions to display measured values for other functions.
For example, a change of input cable connections or function switching is required to perform the measuring of different functions with existing single-display multimeters. A single VOAC7523H/7520H unit can perform these two types of measurements simultaneously.


Dual display

Conventionally, cable disconnection and function switching were required to perform different types of measuring. A VOAC752xH Series single unit can perform measuring that requires multiple units to improve measurment efficiency.
For example, when measuring power consumption (apparent power, VA), simultaneous measuring and operations of voltage and current enable real-time power measuring.


Versatile interface

A RS-232 interface is equipped as standard. In addition, LAN (Ethernet 10BASE-T) or GP-IB interfaces can be selected as options.


Long-time interval measurements of 3000 hours


Using interval measurement of 10 ms to 3600 s in combination with data saving functions with up to 3000 time stamps, measurements of maximum 3000 hours can be performed. The time stamp resolution is 10 ms.


True RMS measuring

All series models can measure true RMS AC voltage and AC current.


Versatile mathematical functions

Decibel operations (dBm, dBμ), scale operations (SCLE), moving averages (AVG), difference operations (REL), statistical operations (MAX, MIN), comparison operations (COMP), and arithmetic calculations between dual functions.


DIO (Digital Input/Output) output useful for production lines (option)

Using trigger and open collector outputs in combination with 5-step pass/fail judgment levels, application to production lines is facilitated.


* Accuracy (±X% of reading +Y digits) indicated by X+Y

The measuring accuracy indicated below can be obtained for a year following the calibration of the instrument.

1. Typical Sample Rate and Resolution

Sample Rate

Resolution

Reading Rate

Hum Rejection

SLOW

5.5-digit

approx. 4 times/sec

Yes

MID

5.5-digit

approx. 20 times/sec

Yes

FAST

4.5-digit

approx. 100 times/sec

N/A


2. DC Volt (DCV) 50mV range is for the VOAC7523H / 7522H only.


Range

Resolution

Input Resistance

Accuracy*


5.5-digit

4.5-digit


SLOW/MID

FAST

50mV

0.1μV

1μV

100MW or more

0.025+10

0.025+15

500mV

1μV

10μV

1000MW or more

0.012+5

0.012+2

0.012+10

0.012+7

5V

10μV

100μV

50V

100μV

1mV

approx. 10MW

0.016+5

0.016+10

500V

1mV

10mV

0.016+2

0.016+7

1000V

10mV

100mV




The accuracy in the 50mV and 500mV ranges is specified after zero compensation through the REL operation.
Sample rate in the 50mV range
SLOW/MID: Approx. 0.5 times/sec, FAST: Approx. 50 times/sec
Max. input voltage:50mV to 5V range ± 800V (continuous)
50V to 1000V range ± 1100V (continuous)


Resolution and noise rejection

Resolution

Sample Rate

NMRR

CMRR

5.5-digit

SLOW

55dB or more

120dB or more

5.5-digit

MID

55dB or more

120dB or more

4.5-digit

FAST

0dB

55dB or more


3. CH-B DC Volt (DCV) VOAC7523H / 7520H only

Range

Resolution

Input Resistance

Accuracy*

4.5-digit

SLOW/MID

FAST

5V

100μV

CH-B:H to CH-B:L 10MW ± 3%
CH-B:H to CH-A:L 5MW ± 3%
CH-B:L to CH-A:L 5MW ± 3%

0.025+2

0.025+30

50V

1mV

0.025+8

300V

10mV

0.025+5


Max. input voltage:± 300V, between CH-A L and CH-B ± 300V
Resolution and noise rejection

Resolution

Sample Rate

NMRR

CMRR

Isolation between CH-A and CH-B

4.5-digit

SLOW/MID

55dB or more

120dB or more

56dB or more

4.5-digit

FAST

0dB

55dB or more



4. AC Volt (ACV, DC+ACV) detection of True RMS

Up to 100kHz for VOAC7521H / 7520H


Range

Resolution

Measurement Range

Input Resistance

5.5-digit

SLOW

MID/FAST

500mV

1μV

15Hz to 300kHz

200Hz to 300kHz

less than approx.
1MW // 100pF

5V

10μV

50V

100μV

500V

1mV

45Hz to 100kHz

200Hz to 100kHz

750V

10mV

45Hz to 20kHz

200Hz to 20kHz


Accuracy: SLOW Sample (Sine wave Amplitude at 5% to 99% of fullscale of range)


Frequency

Accuracy*

15Hz to 45Hz

0.5+150

45Hz to 100Hz

0.25+150

100Hz to 30kHz

0.2+150

30kHz to 100kHz

0.5+300

100kHz to 300kHz

2.5+1000


Coefficient to input other than sine wave


Crest Factor

Crest Factor

1 to 1.5

1.5 to 2

2 to 3

15Hz to 30kHz

0.05%

0.15%

0.30%

30kHz to 300kHz

0.20%

-

-

Resnponse time

Sample Rate

Resolution

Reading Rate

Response Time

SLOW

5.5-digit

4 times/sec

less than 3 sec

MID/FAST

5.5-digit

20 times/sec

less than 2 sec


Max. input voltage: 780Vrms, ± 1100V DC (continuous)In the case of DC+ACV, 500 (less than 45Hz) or 300 (45Hz or higher) must be added to the value of Accuracy digit in above.Sample rate of FAST becomes the same values as MID (approx. 20 times/sec).


5. DC Current (DCA)

Range

Resolution

Accuracy*

Input Resistance

5.5-digit

4.5-digit

SLOW/MID

FAST

5mA

10nA

100nA

0.05+7

0.05+17

150W or less

50mA

100nA

1μA

15W or less

500mA

1μA

10μA

2W or less

10A

100μA

1mA

0.2+7

0.2+17

0.1W or less

Auto range is not available between 5mA to 500mA range and 10A range because of using different input terminals.Max. input current:500mA at 5mA to 500mA ranges (FUSE 0.5A/250V)10A at 10A range (FUSE 15A/250V)

6. AC Current (ACA, DC+ACA)

Range

Resolution

Measurement Range

Input Resistance

5.5-digit

SLOW/MID

FAST

5mA

10nA

15Hz to 5kHz

200Hz to 5kHz

150W or less

50mA

100nA

15W or less

500mA

1μA

45Hz to 5kHz

2W or less

10A

100μA

0.1W or less


Accuracy: SLOW Sample (Sine wave) amplitude at 5% to 99% of fullscale (10% to 99% for10A range)


Frequency

Accuracy*

Crest Factor

1 to 1.5

1.5 to 2

2 to 3

15Hz to 45Hz

1+200

0.05%

0.15%

0.30%

45Hz to 1kHz

0.4+200

1kHz to 5kHz

5.0+200


Response time


Sample Rate

Resolution

Reading Range

Response time

SLOW

5.5-digit

4 times/sec

less than 3 sec

MID/FAST

5.5-digit

20 times/sec

less than 2 sec


Max. input current:500mA for 5mA to 500mA ranges (FUSE 0.5A)10A for 10A range (FUSE 15A)DC Component on input current must be included in the Max. input current.In the case of 10A range at 45Hz to 1kHz, 0.3 must be added to %.In the case of DC+ACA, 500 (less than 45Hz) or 300 (45Hz or higher) must be added to the value of Accuracy in above.Sample rate of FAST becomes the same value as MID (approx. 20 times/sec).


7. Resistance (2 WireW/4 WireW) 4 WireW: VOAC7522H / 7521H only

Range

Resolution

Accuracy*

Test Current

SLOW/MID

FAST

SLOW/MID

FAST

50W

0.1mW

1mW

0.025+10

0.025+15

approx. 10mA

500W

1mW

10mW

0.014+3

0.014+8

approx. 10mA

5kW

10mW

0.1W

approx. 1mA

50kW

0.1W

1W

approx. 100μA

500kW

1W

10W

0.015+3

0.015+33

approx. 10μA

5MW

10W

10W

0.033+30

0.033+30

approx. 1μA

50MW

100W

100W

0.25+30

0.25+30

approx. 100nA

500MW

1kW

1kW

1.5+50

1.5+50

approx. 10nA


Max. input voltage: ± 500V peakOpen circuit test voltage: 12V or lessThe accuracy at 50W to 5kW range are specified after zero compensation through the REL operation.Sample rate of FAST at 5MW to 500MW range becomes the same value as MID (approx. 20 times/sec).


8. Low-Power Resistance (2 WireW)

Range

Resolution

Accuracy*

Test Current

SLOW/MID/FAST

SLOW/MID

FAST

500W

10mW

0.1+5

0.1+15

approx. 1mA

5kW

0.1W

approx. 100μA

50kW

1W

approx. 10μA

500kW

10W

0.2+30

0.2+40

approx. 1μA

5MW

100W

0.2+30

approx. 100nA

50MW

1kW

1.5+30

1.5+30

approx. 10nA


Max. input voltage: ± 500V peakOpen circuit test voltage: 12V or lessThe accuracy at 500W to 5kW range are specified after zero compensation through the REL operation.Sample rate of FAST at 5MW to 500MW range becomes the same value as MID (approx. 20 times/sec).Indications are in 4.5 digits for SLOW, MID, and FAST.


9. Diode

Test Current

Measurement Range

Accuracy*

Open Circuit Test Voltave

Max. Input Voltave

approx. 1mA or 10mA

0.1mV to 5.0999V

0.014+13

12V or less

± 500V peak



10. Temperature


Thermocouple

Temperature Range to be Measured

Accuracy*

Resolution

Max. Input Voltave

R

-50°C to 0°C

0.2+70

0.1°C

± 500V peak

0°C to +100°C

0.2+50

+100°C to +1768°C

0.2+30

K(CA)

-200°C to -100°C

0.15+50

-100°C to 0°C

0.15+35

0°C to +1372°C

0.15+20

T(CC)

-200°C to -100°C

0.15+50

-100°C to 0°C

0.15+35

0°C to +400°C

0.15+20

J(IC)

-200°C to -100°C

0.15+50

-100°C to 0°C

0.15+35

0°C to +1200°C

0.15+20

E(CRC)

-200°C to -100°C

0.15+50

-100°C to 0°C

0.15+35

0°C to +1000°C

0.15+20


The above accuracy values do not include the thermocouple accuracy.±0.1°C/°C is added (for all thermocouples) with the operating ambient temperature of this product at 0°C to 18°C and 28°C to 50°C.accuracy is not specified. In the temperature range to be measured at -200°C or lower,The reference thermo electric force is calculated by the "broken line approximation" according to JIS C 1602-1995.If this product and the thermocouple are connected via a plug, an error for contact temperature compensation is added.


11. Frequency (AC couple, Crest Factor: less than 3)

Sample Rate

Reading Rate
(Gate time)

Display Digits and Measurement Range

Accuracy*

SLOW

approx. 0.5 times/sec (1s)

6-digit

15.0000Hz to 1.00000MHz

0.02+2

MID

approx. 4 times/sec (100ms)

5-digit

15.000Hz to 1.0000MHz

FAST

approx. 10 times/sec (10ms)

4-digit

150.00Hz to 1.000MHz


AC couple: Crest factor <=3AUTO range of ACV must be used with input attenuator.Max. input voltage: 780 Vrms, ± 1100V peak


12. Chart for combination of Dual Function


DCV

CH-B
DCV (*1)

ACV

DC+
ACV

DCA

ACA

DC+
ACA

2 WireW

4 WireW(*2)

Hz

°C

DCV

N/AAvailablehave a limitationhave a limitationhave a limitationhave a limitationhave a limitationN/AN/Ahave a limitationhave a limitation

CH-B
DCV (*1)

AvailableN/AAvailableAvailableAvailableAvailableAvailableAvailable-AvailableAvailable

ACV

have a limitationAvailableN/AAvailableAvailablehave a limitationhave a limitationN/AN/AAvailableN/A

DC+ACV

have a limitationAvailableAvailableN/AAvailablehave a limitationhave a limitationN/AN/AAvailableN/A

DCA

have a limitationAvailableAvailableAvailableN/Ahave a limitationhave a limitationhave a limitationhave a limitationAvailableN/A

ACA

have a limitationAvailablehave a limitationhave a limitationhave a limitationN/AAvailablehave a limitationhave a limitationhave a limitationN/A

DC+ACA

have a limitationAvailablehave a limitationhave a limitationhave a limitationAvailableN/Ahave a limitationhave a limitationhave a limitationN/A

2 WireW

N/AAvailableN/AN/Ahave a limitationhave a limitationhave a limitationN/Ahave a limitationN/AN/A

4 WireW(*2)

N/A-N/AN/Ahave a limitationhave a limitationhave a limitationhave a limitationN/AN/AN/A

Hz

have a limitationAvailableAvailableAvailableAvailablehave a limitationhave a limitation-N/AN/AN/A

°C

have a limitationAvailableN/AN/AN/AN/AN/AN/AN/AN/AN/A

Available: Availablehave a limitation: N/A: N/A- : not provided


(*1) CH-B DCV: VOAC7523H / 7520H only(*2) 4 WireW: VOAC7522H / 7521H only

13. General

MATH

Moving Average, Scale, Decibel (dBm, dBμ), Difference, Statistics (MAX, MIN, X, s), Comparison (COMP), Arithmetic Calculation between Dual Function

Memory

DATA

Max. 3000 data with 10 msec resolution time mark (Elapsed time)

SET UP

10

Interfaces (Full Remote)

Standard

RS-232

Option

LAN, GP-IB

Power Supply

Voltage

AC100V, 110V, 220V, 240V

Frequency

50Hz, 60Hz

Power Consumption

21 VA (includes options) or less

Operation Temperature and Humidity


0°C to +50°C (less than 80%RH)
no condensation, 70%RH or less at +40°C to +50°C

Storage Temperature and Humidity


-20°C to +60°C (70%RH or less)
no condensation, includes operation temperature

Size

Measurement

210W x 99H x 353L mm (Options are built into the main unit)

Weight

3.5kg (includes options) or less

Standard Accessories


Fuse, Test Leads, Alignment Screwdriver, Operation Manual(CD-ROM), Power cord



选件:


Product NamePart NumberImage of Product
LAN interface *1SC-351VOAC7520H Series Rear
DIO interface *2SC-352
GP-IB interface *1SC-353
D/A Converter interface *2SC-354
RS232-USB Converter (WindowsXP,Vista,7)SC-525SC-525

4-wire ohms test leadsSC-005SC-005
High-voltage probe
30kVdc max. (can be used only in the Zin of 10MW range)
SC-003SC-003
Clamp-on current probe
DC ± 200A MAX
AC150A rms MAX (40Hz to 500Hz)
SC-011SC-011
Sheath-type thermocouple (Type K)
-200°C to +800°C
SC-0107SC-0107
Surface thermocouple (Type K)
0°C to +500°C
SC-0116SC-0116
Banana plug
(Can be used to connect a thermocouple)
POMONA1286PAMONA1286
High-resistance test leadSC-004SC-004
Test leadsSC-020SC-020
Arrow clip
For SC-020 (AC30V/DC60V/DC3A)
SC-021SC-021
Alligator clip
For SC-020 (AC30V/DC60V/DC10A)
SC-022SC-022
Alligator clip H
For SC-020 (600Vrms, CAT II/10A)
SC-023SC-023
*1The LAN interface SC-351 and GP-IB interface SC-353 cannot be installed at the same time.
*2The DIO interface SC-352 and D/A Converter interface SC-354 cannot be installed at the same time.