Hawke非铠接管型防爆格兰(501/414系列)

Hawke cable glandHawke非铠接管型防爆格兰(501/414系列)

参考价: 订货量:
689.60 100

具体成交价以合同协议为准
2023-10-31 14:40:00
396
属性:
产地:进口;加工定制:否;
>
产品属性
产地
进口
加工定制
关闭
上海颐品自动化科技有限公司

上海颐品自动化科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

Hawke非铠接管型防爆格兰(501/414系列)
Hawke防爆格兰代理商:上海颐品自动化科技有限公司

详细介绍

Hawke非铠接管型防爆格兰(501/414系列)

Hawke非铠接管型防爆格兰密封接头(501/414系列)

  

HAWKE 501/414 CABLE GLANDS

 

HAWKE接管式防爆格兰(501/414系列)

 

HAWKE代理商:上海颐品自动化科技有限公司 

 
Hawke 501/414 Cable Glands

Hazardous Area Cable Glands from Hawke

Hawke非铠接管型防爆格兰(501/414-Hawke Cable Gland)

Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

Hawke防爆格兰代理商:上海颐品自动化科技有限公司(4008552521)

关键词:Hawke防爆格兰,Hawke防爆变径,Hawke防爆堵头,Hawke防爆呼吸阀,Hawke防爆接线盒,Hawke防爆控制箱

Hawke防爆格兰等产品规格书及相关证书-请咨询上海颐品自动化科技有限公司

 

Hawke 501/414 cable glands are suitable for use with non-armoured elastomer and plastic insulated cables installed in conduit for both outdoor and indoor use.

Hawke 501/414 cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC, 3.0-65.3mm outside cable diameters.

When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

♦ Exdb IIC Gb, Exe IIC Gb, Extb IIIC, Db Non-aromoured Cables ATEX & IECEx Cable Gland.

Hawke 501/414 cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.

  • Flameproof Exdb

  • Increased Safety Exeb

  • Dust Extb

  • Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

HAWKE 501/414 CABLE GLAND TECHNICAL SPECIFICATION

  1. Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, Extb IIIC Db

  2. Certificate No’s  – baseefa06ATEX0056X and IECEx BAS 06.0013X

  3. Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC

  4. Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31

  5. Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X

  6. Deluge Protection – DTS01

  7. Operating Temperature Range  -60°C to +100°C

CABLE GLAND SELECTION TABLE FOR HAWKE 501/414

Hawke Size Ref.Male Entry Thread SizeFemale Entry Thread SizeCable Acceptance Details‘G’ Compressed LengthHexagon Dimensions
Outer Sheath ‘B’
MetricNPT *MetricNPT #Standard SealAlternative (S) SealAcross FlatsAcross Corners
StandardOptionMin.Max.Min.Max.
OsM20 ‡½”M203.08.054.524.026.5
OM20 ‡½”M206.511.954.524.026.5
AM20¾”½”M2010.014.39.013.456.430.032.5
BM251″¾”M2513.020.29.515.448.236.039.5
CM321¼”1″M3219.026.515.521.261.646.050.5
C2M401½”1¼”M4025.032.522.028.064.655.060.6
DM502″1½”M5031.544.4/42.3 †27.534.883.265.070.8
EM632½”2″M6342.556.3/54.3 †39.046.583.280.088.0
FM753″2½”M7554.568.2/65.3 †49.558.386.495.0104.0

Cembre cable lugs available to crimp and terminate cable conductors to ensure complete termination of cable.

CABLE GLAND MATERIAL & FINISH

Hawke 501/414 cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

PREPARING CABLE & GLAND FOR INSTALLING HAWKE 501/414

Hawke 501/414 Cable & Gland Preparation

CABLE PREPARATION

Pull sufficient length ‘I’ of cable through conduit/cable gland to suit equipment. Screw backnut (1) onto pre-threaded conduit/cable gland and tighten with spanner/wrench.

CABLE GLAND PREPARATION

Pass the cable through the entry (5) and seal which may have previously been fitted into the equipment.

Locate the running coupler (2) onto the entry (5) and tighten using a wrench/spanner until resistance is felt between the seal and cable, then turn the running coupler through a further half to one full turn to complete the inner seal, ensuring that entry (5) is prevented from turning and backnut (1) remains tight on the conduit. This procedure compresses the seal into contact with the cable outer sheath.

 

➡ Click Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.

  • 501/421 Cable Gland Unarmoured   – outer cable sheath cable sealing

  • 501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath

  • 501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas

  • ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

  • ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

Hawke防爆格兰(Hawke Cable Gland)

Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

Hawke防爆格兰代理商:上海颐品自动化科技有限公司(4008552521)

关键词:Hawke防爆格兰,Hawke防爆变径,Hawke防爆堵头,Hawke防爆呼吸阀,Hawke防爆接线盒,Hawke防爆控制箱

Hawke防爆格兰等产品规格书及相关证书-请咨询上海颐品自动化科技有限公司

上海颐品代理Hawke非铠接管型防爆格兰密封接头(501/414系列) 


上一篇:CMP/Hawke/Peppers防爆格兰在现场仪表中的应用 下一篇:EPIN代理分销HAWKE铠装防爆接头应用领域和特性
热线电话 在线询价
提示

仪表网采购电话