详细阐述德国DIN EN ISO11997-1循环腐蚀测试标准的试验方法和步骤

时间:2025-05-10      阅读:162

德国DIN EN ISO11997-1循环腐蚀测试标准及复合盐雾测试方法

Cycle A

C.1 Salt fog test solution盐雾试验溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.
按照第5条所述的方法制备喷雾溶液,将氯化钠溶解在水中,使溶液的浓度为(50±10g/L,溶液的pH值在67范围内。

C.2 Cycle

Set up the cabinet to perform the following cycle设置盐雾箱执行以下循环
StepTime hTemp ConditionNotes
1235±2Salt spray 
2460±2Dry:20-30% 
3250±2Wet:95%RH or over 
4Go back to step 1This makes a total cycle time of 8h from step1 to step3
 Transtition time(ie time allowed to reach the temperature and relative humidity specified for a condition after changing to that condition):From salt spray to dry:within 30min
从盐雾到干燥:30min内
From dry to wet:within 150 min
从干到湿:150分钟内
From wet to salt spray:within 30min
从湿到盐雾:30分钟内
The effect of the salt spray will,in principle,be instaneous。
For details of drying-air flow,see 6.4
盐雾的效果在原则上是瞬时的。
有关干燥空气流量的详细信息,请参见6.4
 

C.3 Salt fog depsiton rate盐雾沉降率

The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)
当盐雾在24小时内被收集时,盐雾的沉积速率应该是1ml/h2ml/h(见第10条)

C 4 Duration持续时间

Unless otherwise agreedrepeat the test cycle for 30 cycles(240h),60cycles(240h),90cycles(720h) or 180cycles(1440h)
除非另有约定,重复测试周期30周期(240h)、60周期(240h)、90周期(720h)或180周期(1440h

Cycle B

C.1 Salt fog test solution盐雾试验溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.
按照第5条所述的方法制备喷雾溶液,将氯化钠溶解在水中,使溶液的浓度为(50±10g/L,溶液的pH值在67范围内。

C.2 Cycle

Set up the cabinet to perform the following cycle. 设置盐雾箱执行以下循环。
StepTime hTemp Conditionnotes
12435±2Salt fog 
2840±299%RHWater condensing on test panels
31623±250±20%RH 
4840±299%RHWater condensing on test panels
51623±250±20%RH 
6840±299%RHWater condensing on test panels
71623±250±20%RH 
8840±299%RHWater condensing on test panels
91623±250±20%RH 
104823±250±20%RH 
11Go back to step 1This makes the total cycle time 7 days from step1 to step10.
NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.
 

C 3 Salt fog depsiton rate盐雾沉降率

The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)

C 4 Duration持续时间

Unless otherwise agreedrepeat the test cycle for 840 h
除非另有约定,重复测试周期为840小时。
 

Cycle C

C.1 Salt fog test solution盐雾试验溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (0.31±0.01)g/l and (4.1±0.01)g/l respectively  .The PH of the solution shall be in the range 6 to 7.
按照第5条所述的方法制备喷雾溶液,在水中溶解氯化钠,浓度分别为(0.31±0.01g/L和(4.1±0.01g/L,溶液的pH值在67范围内。

C.2 Cycle

Set up the cabinet to perform the following cycle. 设置来执行以下循环。
StepTime minTemp Conditionnotes
121030±2Salt fog 
221040±2DryDrying-air purge(see 6.4)
3147040±275±15%RHOne method of achieving this conditon is to alternate the dry and humid cycles for suitable(short)time periods to keep the RH between the limits specified
410230±2DryDrying-air purge(see 6.4)
521030±2Salt fog 
637830±290% to 99%RHWater condensing on test panel
718035±2DryDrying-air purge(see 6.4)
812025±2Dry 
9Go back to step 1This makes the total cycle time 48h from step1 to step8.
NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.
 

C 3 Salt fog depsiton rate盐雾沉降率

The salt fog deposition rate shall be 2ml/h to 4ml/h,when the salt fog iscollected over a 24h period (see Clause 10)
当盐雾在24小时内被收集时,盐雾的沉积速率应为2ml/h4ml/h(见第10)

C 4 Duration持续时间

Unless otherwise agreedrepeat the test cycle for1000h
除非另有约定,重复测试周期为1000小时。

Cycle D

C.1 Salt fog test solution盐雾试验溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.
按照第5条所述的方法制备喷雾溶液,将氯化钠溶解在水中,使溶液的浓度为(50±10g/L,溶液的pH值在67范围内。

C.2 Cycle

Set up the cabinet to perform the following cycle,设置执行如下下循环
StepTime hTemp ConditionNotes
10.530±2Salt spray 
21.530±2Wet:(95±3%RH 
3250±2Hot dry 
4230±2Warm dry 
5Go back to step 1This makes a total cycle time of 6h from step1 to step4
 Transtition timeie time allowed to reach the temperature and relative humidity specified for a condition after changing to that condition):From salt spray to wetwithin 10min
从盐雾到潮湿:10min以内
From wet to hot drywithin 15 min
从湿到热干燥:15分钟内
From hot dry to salt warm drywithin 30min
从热干燥到盐温干燥:30min
From salt warm dry to salt sprayinstaneous
从盐温干到盐雾:瞬时
NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.
 

C 3 Salt fog depsiton rate盐雾排放率

The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)
当盐雾在24小时内被收集时,盐雾的沉积速率应该是1ml/h2ml/h(见第10条)

C 4 Duration持续时间

Unless otherwise agreedrepeat the test cycle for 28 cycles(168h)
除非另有约定,重复测试周期为28个周期(168h)。

 