结合R&S频谱分析仪,R&S.TS-EMF测量系统可检测环境中的高频电磁场(EMF)。将全向天线与专门为EMF测量而设计的软件结合使用,可在现场简单而精确地评估总体辐射和特定辐射。
按照国家和国际标准测量EMF辐射,为确保发射机系统符合相应的限值,并将这种信息传达给公众提供了根据。关键准则是能够进行精确和方便的现场测量。
R&S®TS-EMF测量系统通过提供自动测试序列, 包括预配置的测量包来为用户提供支持。全向天线可以不受方向和极化方式影响而检测场强。罗德与施瓦茨的很多频谱分析仪和测试接收机可用于执行这种测量。特别是使用R&S®FSL频谱分析仪的紧凑型单机解决方案,甚至可以在难以到达的位置执行测量。
安全可靠,精确测量获得可重复和可靠的结果
高效的现场测量
适用于多种应用
面向未来
Isotropic antennas | R&S®TSEMF-B3 | R&S®TSEMF-B1 | R&S®TSEMF-B2 |
Measurement principle | isotropic reception due to orthogonally arranged antenna elements that are electronically switched | ||
Frequency range | 9 kHz to 200 MHz | 30 MHz to 3 GHz | 700 MHz to 6 GHz |
Minimum detectable field strength | approx. 1 mV/m | ||
Maximum field strength | ≥100 V/m | ≥230 V/m | ≥230 V/m |
Isotropy | ≤ ±1.37 dB | ≤ ±2.1 dB, ±1.0 dB (f = 900 MHz), ±1.7 dB (f = 1800 MHz) | ≤ ±2.5 dB (0.6 GHz to 2 GHz), ≤ ±2.2 dB (2 GHz to 3.6 GHz), ≤ ±3.0 dB (3.6 GHz to 6 GHz) |
Mechanical design | radome protection against mechanical damage and environmental hazards | ||
Antenna factor | individual calibration data, saved on USB dongle and/or CD | ||
Axis switching | RF solid state switch | ||
Connecting cables | direct connection to spectrum analyzer (extension cable (length: 8 m) see accessories) | integrated cable (length: 2 m) ferritebeaded (extension cable (length: 8 m) see accessories) | integrated cable (length: 2 m, extension cable (length: 8 m) see accessories)) |
RF connector | N male | ||
Connector, control line | 7-pin connector (binder) for direct connection to R&S®FSH power sensor port, adapter cable for connection to notebook or spectrum analyzer with USB output | ||
Tripod adapter | ¼-" thread, quick connector for antenna | ||
Requirements for notebook (not supplied) | MS Windows7 or Windows8 operating system, free hard disk space: min. 5 Gbyte display resolution: min. 800 × 600 pixel, two USB interfaces interface to test instrument (depending on analyzer: GPIB, LAN, USB or FireWire) recommended application: Excel 2007, 2010, 2013 | ||
Equipment supplied | isotropic sensor with connecting cable operator’s guide for R&S®RFEX and R&S®RFEX-Fast measurement software (on CD), tripod adapter, USB adapter cable, transit case (R&S®TS-EMF with at least one isotropic antenna) | ||
Expanded measurement uncertainty R&S®TS-EMF with R&S®FSH (95 % confidence level (k = 2)) | ≤ ±2.5 dB | ≤ ±3.3 dB, ±2.3 dB at 0.9 GHz, ±2.9 dB at 1.8 GHz | ≤ ±3.1 dB (0.7 GHz to 1 GHz), ≤ ±3.3 dB at (1 GHz to 3.6 GHz), ≤ ±3.7 dB at (3.6 GHz to 6 GHz) |
Expanded measurement uncertainty R&S®TS-EMF with R&S®FSL (95 % confidence level (k = 2)) | ≤ ±2.4 dB | ≤ ±3.2 dB, ±2.2 dB at 0.9 GHz, ±2.9 dB at 1.8 GHz | ≤ ±2.9 dB (0.7 GHz to 1 GHz), ≤ ±3.2 dB at (1 GHz to 3.6 GHz), ≤ ±3.6 dB at (3.6 GHz to 6 GHz) |
Power supply | via spectrum analyzer or laptop | ||
Ambient conditions | –10 °C to +50 °C, safety class IP54 (see user manual for details) | ||
Weight (incl. cable) | 0.85 kg 1.87 lb | 1.3 kg 2.87 lb | 0.95 kg 2.09 lb |
Dimensions (L × ∅) | 550 mm × 146 mm 21.7 in. × 5.75 in. | 475 mm × 170 mm 18.7 in. × 6.69 in. | 415 mm × 87 mm 16.3 in. × 3.43 in. |