SPECIFICATIONS | MODEL | 7450 | 7451 | 7452 | AC WITHSTAND VOLTAGE | Output Rating | 5KVAC/100mA Constant 500VA | Range | Resolution | Accuracy | Output Voltage, ACV | 0 - 5000 | 1 | ±(2% of setting + 5V) | Output Frequency | 50Hz/60Hz ±100ppm, User Selection | Output Waveform | Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 - 1.5 | Output Regulation | ± (1% of output + 5V), From no load to full load | SETTINGS | Hi-Limit AC Current, mA | 0 - 99.99 | 0.01 | ±(2% of setting + 3counts) | Lo-Limit AC Current, mA | 0 - 9.999 | 0.001 | ±(2% of setting + 3counts) | Ramp Time, second | 0.1 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | Dwell Time, second | 0, 0.3 - 999.9 (0=continuous) | 0.1 | Arc Detection | 1 - 9 ranges (9 is the most sensitivity) | AC Current Offset, mA | 0 - 2.000 or Auto Set | DC WITHSTAND VOLTAGE (7451,7452 ONLY) | Output Rating | 6KVDC/9999µA | Output Voltage, DCV | 0 - 6000 | 1 | ±(2% of setting + 5V) | Output Ripple | <5%(6KV/9999µA at Resistive Load) | SETTINGS | Hi-Limit DC Current, µA | 0 - 9999 | 1 | ±(2% of setting + 3counts) | Lo-Limit DC Current, µA | 0 - 999.9 | 0.1 | ±(2% of setting + 3counts) | Ramp Time, second | 0.1 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | Dwell Time, second | 0, 0.4 - 999.9 (0=continuous) | 0.1 | Arc Detection | 1 - 9 ranges (9 is the most sensitivity) | DC Current Offset, µA | 0 - 200.0 or Auto Set | Ramp High Current | ON/OFF, User Selection | Charge - Low Current, µA | 0 - 350.0 or Auto Set | Discharge Time | < 200 msec | INSULATION RESISTANCE | Output Rating | 1KVDC/9999MΩ | Output Voltage, DCV | 100 - 1000 | 1 | ±(2% of setting + 3V) | Hi-Limit Resistance, MΩ | 0, 1 - 9999 (0=OFF) | 1 | ±(2% of setting+2counts)at 500-1000VDC, 1 -1000 MΩ ±(8% of setting+2counts)at 500-1000VDC, 1000 -9999 MΩ ±(8% of setting+2counts)at 100-500VDC, 1 -1000 MΩ | Lo-Limit Resistance, MΩ | 1 - 9999 | 1 | Delay Time, second | 0, 0.5 - 999.9 (0=continuous) | 0.1 | ±(0.1% + 0.05sec) | Charge - Low Current, ?A | 0 - 3.500 or Auto Set | GROUND BOND (7452 ONLY) | Output Rating | 30A/600mΩ, 8V | Output AC Current, A | 3.00 - 30.00 | 0.01 | ± (2% of setting +2 counts) | Output AC Voltage, V | 3.00 - 8.00 | 0.01 | ± (2% of setting +3 counts) | Output Frequency | 50Hz/60Hz ±100ppm, User Selection | SETTINGS | Hi-Limit Resistance, mΩ | 0 - 150 (3 - 30A) | 1 | ± (2% of setting +2 counts) | Lo-Limit Resistance, mΩ | 0 - 600 (3 - 10A) | Lead Resistance Offset, mΩ | 0 -200 | 1 | ± (2% of setting +2 counts) | Dwell Time, second | 0, 0.5 - 999.9 sec (0 = continuous) | 0.1 | ±(0.1% + 0.05sec) | MEASUREMENT | AC/DC Voltage, KV | 0 - 6.00 | 0.01 | ±(1.5% of reading + 1count) | DC Voltage, V (IR) | 100 - 1000 | 1 | ±(1.5% of reading + 3count) | AC Current Range, mA | 0-3.500 | 0.001 | ±(2% of reading + 3counts) | 3.00-99.99 | 0.01 | ±(2% of reading + 6counts) | DC Current Range, µA | 0-350.0 | 0.1 | ± (2% of reading + 3counts) | 300 - 3500 | 1 | ± (2% of reading + 2counts) | 3000-9999 | 10 | ± (2% of reading + 6counts) | AC Current, A (GB) | 0 - 35.00 | 0.01 | ±(2% of reading+2counts) | Resistance, , MΩ(IR) | 1 - 9999 (Auto Range) | — | ±(2% of reading+2counts)at 500-1000VDC, 1 -1000 MΩ | ±(8% of reading+2counts)at 500-1000VDC, 1000 -9999 MΩ | ±(8% of reading+2counts)at 100-500VDC, 1 -1000 MΩ | Resistance, , mΩ(GB) | 0 - 600 | 1 | ±(2% of reading+2counts) | GENERAL | Input Voltage AC | 100/115/200/230Vac±15%, 50/60Hz ± 5%, Fuse 15A | PLC Remote Control | Input : Test , Reset , Memory1.2.3 | Output : Pass , Fail , Processing | Memory | 50 memories, 8 steps/memory | Display | 20×2 LCD with back light | Key Lock | To prevent unauthorized alteration of the test Parameters | Calibration | Build-in software and external calibrated meters | Alarm Volume Setting | Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. | Rear Panel Output | YES | YES | YES | Built-in Scanner | - | - | - | External Scanner | - | YES | YES | Smart GFI | YES | YES | YES | Analog Meter | YES | YES | YES | RS232 Interface | - | Option | Option | GPIB Interface | - | YES | YES | Printer Interface | - | Option | Option | TUV-GS listed | YES | - | YES | CE Compliance | YES | - | YES | Environment | 0-40℃, 20-80%RH | Dimension (W×H×D) | 430×133×400 (mm) | 430×133×400 (mm) | 430×133×500 (mm) | Net Weight | 28Kg | 28Kg | 32Kg | STANDARD ACCESSORIES | Power Cord(15A) | ×1 | Fuses | ×2 (Including a spare contained in the fuse holder) | Hipot Test Lead ,1.5m(1101) | ×1 | ×1 | ×1 | Hipot Return Lead ,1.8m(1102) | ×1 | ×1 | - | Ground Bond Test Lead 30A ,1.5m(1103) | - | - | ×1 | Ground Bond Return Lead 30A ,1.5m(1104) | - | - | ×1 | *product specifications are subject to change without notice. |
|