ABB断路器弹簧电机1YHB00000000108 ,ABB弹簧充电电机 Motor for circuit-breaker springs charging M-MS-MAS aux voltage 220-250V 。ABB弹簧充电电机 circuit breaker spring charging Motor, Opening release,Closing release,Undervoltage release。Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 220-250Vdc,110-130Vdc/ac,48-60Vdc,4-30Vdc。
1YHB00000000105 *储能电机MS DC24-30V
1YHB00000000106 *储能电机MS DC48-60V
1YHB00000000107 *储能电机MS DC/AC110-130V
1YHB00000000108 *储能电机MS DC220-250V
1YHB00000002455 *底盘电机24V
1YHB00000002456 *底盘电机30V
1YHB00000002262 *底盘电机48V
1YHB00000002457 *底盘电机60V
1YHB00000000452 *底盘电机110V
1YHB00000000453 *底盘电机220V
自动对合闸弹簧储能的齿轮式电动机 (M)齿轮式电动机可自动对操作机构的合闸弹簧储能;当断路器合闸动作完毕,齿轮式电动机立即对合闸弹簧储能。
合闸弹簧亦可在维护时或无控制电源时手动储能 (利用操作机构的杠杆)。同时,也可安装一个限位开关及微动开关来监视合闸弹簧是否已储能 (参考附件 5d)。参考线路图: M (1)
弹簧储能电动机特性
电源 (Un) 24-30 V AC/DC
48-60 V AC/DC
100-130 V AC/DC
220-250 V AC/DC
运行条件85%...110% Un, 380...415 V AC/DC (CEI EN 60947-2 标准)
冲击功率 (Ps) DC = 300 W (X1) / 500 W (E1-E6)
AC = 300 VA (X1) / 500 VA (E1-E6)
额定功率 (Pn) DC = 100 W (X1) / 200 W (E1-E6)
AC = 100 VA (X1) / 200 VA ( E1-E6)
冲击时间0.2 s
储能时间8-10 S (X1) / 4-5 S (E1-E6)
绝缘电压2500 V 50 Hz (1 分钟)
合闸弹簧储能后的信号接点使用一个微动开关可以摇控指示操作机构内合闸弹簧的储能状态 (与齿轮式弹簧储能电动机一起供应)。
ABB断路器弹簧电机1YHB00000000108
1VCF339751S8902 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 24-30Vdc for Vmax, ADVAC-VD4 up to 40kA except VD4 40kA with EL3S and VD4/R
1VCF339751S8904 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 48-60Vdc for Vmax, ADVAC-VD4 up to 40kA except VD4 40kA with EL3S and VD4/R
1VCF339751S8909 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 110-130Vdc/ac for Vmax, ADVAC-VD4 up to 40kA except VD4 40kA with EL3S and VD4/R
1VCF339751S8918 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 220-250Vac for Vmax, ADVAC-VD4 up to 40kA except VD4 40kA with EL3S and VD4/R
1VCF339751S8948 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 220-250Vdc for Vmax, ADVAC-VD4 up to 40kA except VD4 40kA with EL3S and VD4/R
1VCF339757S4902 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 24-30Vdc for VD4 40kA with EL3S
1VCF339757S4904 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 48-60Vdc for VD4 40kA with EL3S
1VCF339757S4909 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 110-130Vdc/ac for VD4 40kA with EL3S
1VCF339757S4948 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 220-250Vac for VD4 40kA with EL3S
1VCF339757S4918 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 220-250Vdc for VD4 40kA with EL3S
1VCF339850S0902 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 24-30Vdc for VD4/R EL
1VCF339850S0904 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 48-60Vdc for VD4/R EL
1VCF339850S0909 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 110-130Vdc/ac for VD4/R EL
1VCF339850S0918 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 220-250Vdc for VD4/R EL
1VCF339850S0948 Motor for circuit-breaker springs charging M-MS-MAS aux. voltage 220-250Vac for VD4/R EL
操作机构是属于储能型的,也就是用预先储能的弹簧操作。
弹簧储能可以手动操作前面盘的手柄或利用齿轮式电动机电动操作。
分闸弹簧在合闸 (closing) 操作时自动储能。
通过安装在操作机构内部的合闸及分闸线圈,以及使用齿轮式电动机对弹簧储能,断路器可以实现遥控操作,如需要,还可与
监控系统配合。