Hawke S-Series Size4L Enclosure,Hawke不锈钢防爆接线盒
Hawke S-Series Size4L Enclosure,Hawke不锈钢防爆接线盒

Hawke S-Series Size4L Enclosure,Hawke不锈钢防爆接线盒

参考价: 面议

具体成交价以合同协议为准
2022-12-05 07:43:47
449
产品属性
关闭
上海颐品自动化科技有限公司

上海颐品自动化科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

Hawke S-Series Size4L Enclosure,Hawke不锈钢防爆接线盒
Hawke S-Series Size4L Enclosure,Hawke不锈钢防爆接线盒
上海颐品自动化,:

详细介绍

Hawke S-Series Size4L Enclosure,Hawke不锈钢防爆接线盒
Hawke S-Series Size4L Enclosure,Hawke不锈钢防爆接线盒
上海颐品自动化,:

Hawke S-Series Size4L Enclosure

Increased Safety Exe / Dual Certified ATEX - IECEx

Materials & Finishes

316 L Stainless Steel.

MAXIMUM QUANTITY OF ENTRIES PER FACE
Thread SizeM16M20/OM20/AM25M32M40M50M63M75
Bottom Face C Quantity44 #4232261411643
Side Faces B & D
Quantity
26 #181811654 *21
# Serrated washers/locknuts with large outside diameters may foul on adjacent cable glands.
* Serrated washers/locknuts must not foul on aperture wall.
TERMINAL CAPACITY DATA
Terminal TypeConductor Size (mm²)Max.
Volts
Max. Physical
Terminal Content
Reduced Terminal Content
At Max. Terminal Amps
Min.Max.Terminal
Quantity
AmpsTerminal
Quantity
Amps
WDU 2.50.52.555025241917
WDU 40.5469018861822
WDU 60.5655014491529
WDU 101.510550112131340
WDU 161.51669096181153
WDU 352.5356907230887
WDU 5065069060391188
WDU 70N107069045527134
WDU 70/951670690111006134
WDU 70/951695690111168134
WDU 120/1503512069091396162
WDU 120/15035150690914878153
WFF 352.5351100225811376
WFF 702.570110091169116
WFF 1206120110071637162
The enclosure is supplied with an integral internal/external earth stud assembly.
The terminals listed are restricted to a minimum operating temperature of -50°C.

S-Series & EJB Series Enclosures Technical Information

To ensure that the maximum temperature as permitted by certification is not exceeded, the dissipated wattage factor formula is used: W = N x F x I² (see enclosure wattage factor).

It is not permitted to fit more than one conductor per side in rail or direct mounted terminals unless using an insulated Bootlace Ferrule.

Linked and mixed terminal arrangements other than those specified in the data tables are available, but the voltage and current figures may be affected to ensure the maximum certified wattage factor is not exceeded. Please contact Hawke Technical Sales for more information.

For Intrinsically Safe Applications, Exe power terminals can be supplied in blue on request. (Note: the enclosure will remain Exe certified).

The enclosure is provided with an integral internal / external earth stud assembly, but when required, one or more rail mounted earth terminals may be fitted inside the enclosure but the quantity of power terminals shall be reduced accordingly. (Note: power terminals may be used as ‘clean earths’).

The enclosure has metric clearance / plain entry holes as standard. Alternative clearance holes are available provided they are to a recognised standard e.g. BSPP, ET etc. (Parallel threads only). Plain entry holes must maintain the following:
a) The plain hole shall be no larger than 0.7mm above the major diameter of the entry thread.
b) The cable gland or stopping plug is secured internally by a locknut, such that the cable gland or stopping plug will not be dislodged by a 7Nm impact.
c) The enclosure should be maintained at IP66 by the use of a suitable sealing washer under the shoulder of the cable gland.

The customer may drill plain entry holes in the enclosure providing they are in accordance with the relevant code of practice and comply with the certification, contact Hawke Technical Sales for more information.

When mixed entries are required on a face, contact Hawke Technical Sales for more information.

All unused entry holes must be fitted with a stopping plug as listed on the enclosure certificate. The stopping plug shall be held in place by a locknut.

Specification

S-Series Certification: ex logo II2 GD Exe II ExtD.

EJB Series Certification: Certificate No's Baseefa 08ATEX0208X and IECEx BAS08.0065X.

Zones of Use: Zone 1, Zone 2, Zone 21 & Zone 22.

Temperature Class & Ambients: T6 40°C as standard. Optional T5 with ambients up to 65°C.

Operating Temperature Range: 60°C to +80°C.

Degree of Protection: IP66 and Deluge proof to DTS01.

Material: 316 L Stainless Steel.

Finish: Electropolished as standard (optional - unpolished finish).

Impact Resistance: Up to 7Nm.

Weatherproofing: By bonded silicone sponge lid and gland plate gaskets.

Certification Label: Stainless Steel or optional certified self adhesive foil.

Lid Fixing Screws: Stainless Steel (complete with nylon retaining washer).

Additional Options: Breather/Drain devices. Epoxy paint finish for colour coding. EMI/RFI wire mesh on lid gasket for EMC requirements.

Additional Labels: Stainless Steel or laminated plastic (traffolyte) for external use only or optional (certified) self adhesive foil for external and/or internal use.

Window: Windows available for S2 / ZS2 to S9 / ZS9 Stainless Steel boxes. Windows will be located in the lid and are manufactured from 6mm thick toughened glass with a Stainless Steel Grade 316L frame and silicone sponge gaskets which provide IP66 Ingress Protection.

Internal Mounting Plates: The S / ZS Series boxes can be supplied with an internal plated steel or stainless steel mounting plate.

Earth Continuity

These enclosures have an integral internal / external earth stud assembly.

Enclosures Dissipated Wattage

ENCLOSURE DISSIPATED WATTAGE
Enclosure TypeTemperature Class
T6 40°C & T5 55°CT6 55°CT5 40°CT6 65°CT5 65°C
PL5111.61.02.20.61.2
PL513 GRP4.12.55.61.53.5
PL520 GRP4.836.61.83.6
PL612 GRP4.12.55.61.53
PL615 GRP6.448.82.44.8
PL620 GRP11.47.115.64.28.5
PL626 GRP11.47.115.64.28.5
PL630 GRP20.81328.67.815.6
PL642 GRP20.81328.67.815.6
PL644 GRP20.81328.67.815.6
PL712 GRP3.352.144.61.22.4
PL722 GRP5.313.327.31.93.9
Size 1 Stainless Steel13.958.719.15.210.4
Size 2 Stainless Steel18.1511.324.96.813.6
Size 2L Stainless Steel18.1511.324.96.813.6
Size 3 Stainless Steel23.714.832.58.817.7
Size 4 Stainless Steel29.9518.741.111.222.4
Size 4L Stainless Steel29.9518.741.111.222.4
Size 5 Stainless Steel32.8520.545.112.324.6
Size 6 Stainless Steel4025551530
Size 7 Stainless Steel5223.571.519.539
Size 8 Stainless Steel6540.689.324.348.7
Size 9 Stainless Steel79.3549.5109.129.759.5
EJB14.742.966.511.7783.55
EJB26.644.159.132.494.98

Dissipated Wattage Factor

The Dissipated Wattage Factor of the enclosures has been established by test to ensure that the maximum temperature as permitted by temperature certification is not exceeded. When terminal quantities greater than those at maximum amps are required (up to maximum physical quantity only) then the current shall be reduced accordingly to remain within the Dissipated Wattage Factor of the enclosure.

Combined Terminal Resistance Factor

This factor is used to determine the number of terminals that can be accommodated within the enclosure without exceeding the Wattage Factor. The Combined Terminal Resistance Factor is the sum of the individual terminal resistance's and the resistance of the cable core equal in length to the enclosure maximum diagonal. (Core Resistance is taken from BS6360). Combined terminal resistance factor.

Wattage to be Dissipated = N x F x I²

N = Number of Terminals. F = Combined Terminal Resistance Factor. I = Maximum Current.

e.g. Number of terminals in a PL630 Enclosure at 20.8 Watts - 10 x 'WDU 2.5' (1=17A), 2 x 'WDU 6' (1=29A), (10 x 0.003035 x 17 ² = 8.77 watts) + (2 x 0.001404 x 29 ²) = 2.36 watts). Total Watts = 8.77 + 2.36 = 11.13 watts.

Therefore this terminal combination is acceptable as the wattage is less than that of the PL630 maximum watts of 20.8 watts.

Note - If a smaller than maximum permitted conductor is fitted into a power terminal, then the smaller conductor resistance must be used when calculating the combined terminal resistance.

Transposed Formula

enclosures dissipated wattage equation

Combined Terminal Resistance

S-Series Stainless Steel Enclosures

Combined Terminal Resistance (Ω)
Terminal TypeEnclosure Type
Size 1Size 2Size 2LSize 3Size 4Size 4LSize 5Size 6Size 7Size 8Size 9
WDU 2.5N0.0026350.0035090.0040280.0041760.0046500.005190.0052650.0062290.0073620.0084370.009534
WDU 2.50.0026050.0034790.0039980.0041460.0046200.005170.0052350.0061990.0073320.0084070.009504
WDU 40.0017250.0022690.0025920.0026840.0029790.0033200.0033620.0039610.0046660.0053350.006017
WDU 60.0012260.0015890.0018050.0018660.0020630.0022910.0023190.0027190.0031910.0036370.004093
WDU 100.0007620.0009780.0011060.0011420.0012600.0013940.0014110.0016490.0019290.0021950.002466
WDU 160.0005030.0063900.0007190.0074200.0008160.0009000.0009110.0010610.0012370.0014040.001574
WDU 350.0002610.0003230.0003590.0003700.0004030.0004420.0004470.0005150.0005950.0006710.000749
WDU 50N-0.0002340.0002620.0002690.0002940.0003230.0003260.0003760.0004360.0004920.000549
WDU 70N-0.00017400.0001930.0001980.0002150.0002350.0002370.0002720.0003130.0003520.000392
WDU 70/95----0.0002250.0002450.0002470.0002820.0003230.0003620.000402
WDU 70/95----0.0001820.0001960.0001980.0002230.0002520.0002800.000309
WDU120/150----0.0001590.0001700.0001710.0001910.0002150.0002370.000259
WDU 120/150----0.0001420.0001510.0001520.0001680.0001870.0002050.000224
WFF 35-0.0002630.0002990.0003100.0003430.0003830.0003870.0004550.0005350.0006110.000689
WFF 70----0.0001850.0002050.0002070.0002420.0002830.0003220.000362
WFF 120----0.0001090.000120.0001210.0001410.0001650.0001870.000209
WFF 185-------0.0000980.0001140.0001280.000143
WFF 300-------0.0000680.0000770.0000860.000094

S-Series Enclosures Maximum Physical Quantity Of Terminals

W Series Terminals

MAXIMUM PHYSICAL QUANTITY OF TERMINALS
Terminal TypeEnclosure Type
SIZE 1SIZE 2SIZE 2LSIZE 3SIZE 4SIZE 4LSIZE 5SIZE 6SIZE 7SIZE 8SIZE 9
WDU 2.530 (1 rail only)78 (2 rails-39 per rail)117 (3 rails - 39 per rail)126 (2 rails-63 per rail)189 (3 rails-63 per rail)252 (4 rails-63 per rail)249 (3 rails-83 per rail)416 (4 rails-104 per rail)640 (5 rails-128 per rail)912 (6 rails-152 per rail)1232 (7 rails-176 per rail)
WDU 425 (1 rail only)50 (2 rails-25 per rail)75 (3 rails - 25 per rail)94 (2 rails-47 per rail)141 (3 rails-47 per rail)188 (4 rails-47 per rail)192 (3 rails-64 per rail)320 (4 rails-80 per rail)515 (5 rails-103 per rail)720 (6 rails-120 per rail)980 (7 rails-140 per rail)
WDU 619 (1 rail only)42 (2 rails-21 per rail)63 (3 rails - 21 per rail)72 (2 rails-36 per rail)108 (3 rails-36 per rail)144 (4 rails-36 per rail)144 (3 rails-48 per rail)240 (4 rails-60 per rail)380 (5 rails-76 per rail)540 (6 rails-90 per rail)735 (7 rails-105 per rail)
WDU 1015 (1 rail only)36 (2 rails-18 per rail)54 (3 rails - 18 per rail)56 (2 rails-28 per rail)84 (3 rails-28 per rail)112 (4 rails-28 per rail)120 (3 rails-40 per rail)200 (4 rails-50 per rail)300 (5 rails-60 per rail)438 (6 rails-73 per rail)595 (7 rails-85 per rail)
WDU 1613 (1 rail only)28 (2 rails-14 per rail)42 (3 rails - 14 per rail)48 (2 rails-24 per rail)72 (3 rails-24 per rail)96 (4 rails-24 per rail)96 (3 rails-32 per rail)160 (4 rails-40 per rail)250 (5 rails-50 per rail)360 (6 rails-60 per rail)490 (7 rails-70 per rail)
WDU 359 (1 rail only)20 (2 rails-10 per rail)30 (3 rails - 10 per rail)36 (2 rails-18 per rail)54 (3 rails-18 per rail)72 (4 rails-18 per rail)72 (3 rails-24 per rail)120 (4 rails-30 per rail)190 (5 rails-38 per rail)270 (6 rails-45 per rail)371 (7 rails-53 per rail)
WDU 50NN/A16 (2 rails - 8 per rail)24 (2 rails - 12 per rail)28 (2 rails - 14 per rail)42 (3 rails - 16 per rail)60 (4 rails - 15 per rail)56 (3 rails - 14 per rail)96 (4 rails - 24 per rail)155 (5 rails - 31 per rail)216 (6 rails - 36 per rail)308 (7 rails - 44 per rail)
WDU 70NN/A8 (1 rail only)16 (2 rails - 8 per rail)14 (1 rail only)30 (2 rails-15 per rail)45 (3 rails-15 per rail)40 (2 rails-20 per rail)50 (2 rails-25 per rail)93 (3 rails-31 per rail)108 (3 rails-36 per rail)172 (4 rails-43 per rail)
WDU 70/95N/AN/AN/AN/A11 (1 rail only)11* (1 rail only)15* (1 rail only)19* (1 rail only)23* (1 rail only)56* (2 rails-28 per rail)64* (2 rails-32 per rail)
WDU 120/150N/AN/AN/AN/A9* (1 rail only)9* (1 rail only)12* (1 rail only)16* (1 rail only)20* (1 rail only)46* (2 rails-23 per rail)54* (2 rails-27 per rail)
WFF 35N/A6 (1 rail only)6* (1 rail only)11 (1 rail only)11 (1 rail only)22* (2 rails)15* (1 rail only)38* (2 rails-19 per rail)46* (2 rails-23 per rail)84* (3 rails-28 per rail)96 *(3 rails-32 per rail)
WFF 70N/AN/AN/AN/A9* (1 rail only)9* (1 rail only)12* (1 rail only)16* (1 rail only)40* (2 rails-20 per rail)46* (2 rails-23 per rail)81* (3 rails-27 per rail)
WFF 120N/AN/AN/AN/A7* (1 rail only)7* (1 rail only)9* (1 rail only)12* (1 rail only)15* (1 rail only)36* (2 rails-18 per rail)42* (2 rails-21 per rail)
WFF 185N/AN/AN/AN/AN/AN/AN/A9* (1 rail only)11* (1 rail only)13* (1 rail only)32* (2 rails-16 per rail)
WFF 300N/AN/AN/AN/AN/AN/AN/A9* (1 rail only)11* (1 rail only)13* (1 rail only)32* (2 rails-16 per rail)
* If earth terminals are required, the quantity should be taken from the maximum physical terminal quantity.

Notes:

Earths: Size 1 to 9: When rail earths are required, the power terminals shall be reduced accordingly. Size 1 to 9: Internal/external earth stud is suitable for conductors up to 75mm². For larger conductors, contact Hawke International

Rails: Size 1 to 9: If ‘WFF’terminals are required with ‘‘W’ partitions, then the box size and / or rail quantity may change due to the large width of these partitions.

Box Size: Size 1 to 9: ‘WFF’ series terminals shall be fitted in 210 deep enclosures.

WDU 50N, WDU 70N, WDU70/95, WDU120/150, and all WFF series terminals are fitted on ‘heavy duty’ rail.

 

 

 

 

中国区分销商:
上海颐品自动化科技有限公司
Shanghai Epin Automation Co.,Ltd.

Website:www.epinautomation。。com
:sales@epinautomation.com
*:

 

上一篇:德国Pflitsch电缆防水接头品类及特点 下一篇:德国Pflitsch电缆防水接头品类及应用领域
热线电话 在线询价
提示

仪表网采购电话