Specifications |
Model | FSM-50R12: Mass fusion splicer up to 12-fiber FSM-50R8: Mass fusion splicer up to 8-fiber |
Applicable fibers | SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU -T G.653), NZDS (ITU-T G.655) |
Fiber Count | FSM-50R12: Single, 2, 4, 5, 6, 8, 10 and 12 FSM-50R8: Single, 2, 4, 5, 6 and 8 |
Fiber cleaved length | 10mm |
Actual average splice loss | 0.05dB with SM, 0.02dB with MM, 0.08dB with DS, and 0.08dB with NZDS. Measured by cut-back method relevant to ITU-T and IEC standards. |
Splicing time | Typical 20seconds |
Return loss | >>60dB |
Splicing modes | 40 user programmable modes and up to 60 modes for reference (factory predetermined setting). |
Splice loss estimate | Available |
Storage of splice result | FSM50R12: The last 400 results to be stored in the internal memory.FSM50R8: The last 500 results to be stored in the internal memory. |
Fiber display | X / Y, or both X and Y simultaneously. |
Magnification | FSM-50R12: 35x丂丂FSM-50R8: 49x |
Viewing method | Two CMOS cameras and 5.6inch color LCD monitor. |
Operating condition | 0 to 3,660m above sea level, 0 to 95%RH and -10 to 50 ℃ respectively. |
Mechanical proof test | 2N |
Tube heater | Built-in tube heater with 10 heating modes and up to 20 modes for reference. |
Tube heating time | Typical 40seconds with FP-04(T), 45seconds with FP-05 protection sleeves. |
Applicable protection sleeve length | 60mm and 40mm |
No.of splice/heating with battery | Typical 70 cycles with BTR-06(S) / Typical 140 cycles with BTR-06(L). |
Power supply | Auto voltage selection from 100 to 240V AC or 10 to 15V DC with ADC-11, 13.2V DC with BTR-06(S)/(L). |
Terminals | USB 1.1 (USB-B type) for PC communication. Video terminal RCA video jack / NTSC. |
Wind protection | Max. wind velocity of 15m/s. |
Dimensions | 150W x 150D x 150H (mm) |
Weight | 2.2 kg (2.7kg including AC adapter ADC-11) |
Operation languages | 15 type of languages |