淮安市和信仪表有限公司

仪表网免费15

收藏

怎么做好涡街流量计选型

时间:2011-09-05      阅读:2163

流量计仪表选型是否正确是关系到流量的计量的关键工作,要获得准确的测量结果,选型时应该注意,介质温度、压力、流量范围及安装环境等技术参数,其中流量范围的选择尤为重要,流量太小仪表难以检测出信号,流量太大,仪表容易超量程。(下表中仪表口径对应流量范围仅供参考)
 A、测量饱和蒸汽流量范围              (口径DN:mm;流量单位:t/h)

DN
0.1MPa
0.2 MPa
0.3 MPa
0.4 MPa
0.5 MPa
0.6 MPa
6
0.65.6 Kg/h
0.88.2 Kg/h
1.110.8 Kg/h
1.313.3 Kg/h
1.615.8 Kg/h
1.818.3 Kg/h
8
1.010.0 Kg/h
1.514.7 Kg/h
1.919.2 Kg/h
2.423.7 Kg/h
2.828.1Kg/h
3.332.6 Kg/h
10
1.615.7 Kg/h
2.322.9Kg/h
3.030.0 Kg/h
3.737.0 Kg/h
4.444.0 Kg/h
5.150.9 Kg/h
15
3.535 Kg/h
5.151 Kg/h
6.767 Kg/h
8.383 Kg/h
9.898 Kg/h
11.4114 Kg/h
20
6.262 Kg/h
9.191 Kg/h
12120 Kg/h
15150 Kg/h
17.5175 Kg/h
20.3203 Kg/h
25
9.797 Kg/h
14.3143 Kg/h
18.7187 Kg/h
23.1231 Kg/h
27.4274 Kg/h
31.7317 Kg/h
32
16160 Kg/h
23.4234 Kg/h
30.7307 Kg/h
37.9379 Kg/h
45450 Kg/h
51510 Kg/h
40
25.8258 Kg/h
36.6366 Kg/h
48480 Kg/h
59.2592 Kg/h
70.3703 Kg/h
81.3813 Kg/h
50
0.04
0.39
0.05
0.58
0.07
0.76
0.09
0.93
0.11
1.10
0.13
1.30
65
0.06
0.67
0.09
0.97
0.13
1.30
0.16
1.60
0.19
1.90
0.21
2.10
80
0.10
1.00
0.14
1.40
0.19
1.90
0.24
2.40
0.28
2.80
0.33
3.30
100
0.15
1.50
0.23
2.30
0.3
3.0
0.37
3.70
0.44
4.40
0.51
5.10
125
0.23
2.30
0.36
3.60
0.47
4.70
0.58
5.80
0.69
6.90
0.79
7.90
150
0.33
3.30
0.51
5.10
0.68
6.80
0.83
8.30
0.99
9.90
1.14
11.4
200
0.63
6.3
0.92
9.2
1.20
12.0
1.48
14.8
1.76
17.6
2.03
20.4
250
0.98
9.79
1.43
14.32
1.88
18.76
2.31
23.14
2.75
27.47
3.18
31.79
300
1.41
14.10
2.06
20.61
2.70
27.01
3.33
33.32
3.96
39.56
4.58
45.78
350
1.92
19.20
2.81
28.06
3.68
36.76
4.54
45.35
5.38
53.85
6.23
62.31
400
2.51
25.07
3.66
36.65
4.80
48.02
5.92
59.23
7.03
70.33
8.14
81.39
450
3.17
31.73
4.64
46.38
6.08
60.77
7.50
74.97
8.90
89.02
10.30
103.0
500
3.92
39.18
5.73
57.26
7.50
75.03
9.26
92.55
10.99
109.9
12.72
127.2
600
5.64
56.41
8.25
82.46
10.80
108.0
13.33
133.3
15.83
158.3
18.31
183.1

 
 
 

DN
0.7 MPa
0.8 MPa
0.9 MPa
1.0 MPa
1.1 MPa
6
2.120.8 Kg/h
2.323.2Kg/h
2.625.7Kg/h
2.828.1Kg/h
3.130.6Kg/h
8
3.736.9 Kg/h
4.141.3 Kg/h
4.645.7 Kg/h
5.050.0Kg/h
5.454.4 Kg/h
10
5.857.7 Kg/h
6.564.5 Kg/h
7.171.4Kg/h
7.878.2 Kg/h
8.585.0 Kg/h
15
13.0130Kg/h
14.5145 Kg/h
16.1161 Kg/h
17.6176 Kg/h
19.1191 Kg/h
20
23.1231 Kg/h
25.8258 Kg/h
28.5285 Kg/h
31.3313 Kg/h
34.0340 Kg/h
25
36.1361 Kg/h
40.3403 Kg/h
44.6446 Kg/h
48.8488 Kg/h
53.1531 Kg/h
32
59.1591 Kg/h
66.1661 Kg/h
73.1731 Kg/h
80.0800 Kg/h
87.0870 Kg/h
40
92.4924 Kg/h
1031033 Kg/h
1141142 Kg/h
1251250 Kg/h
1361359 Kg/h
50
0.14
1.44
0.16
1.61
0.18
1.78
0.20
1.95
0.21
2.12
65
0.24
2.44
0.27
2.73
0.30
3.02
0.33
3.30
0.36
3.59
80
0.37
3.69
0.41
4.13
0.46
4.57
0.50
5.00
0.54
5.44
100
0.58
5.77
0.65
6.45
0.71
7.14
0.78
7.82
0.85
8.50
125
0.90
9.02
1.00
10.09
1.12
11.15
1.22
12.21
1.33
13.28
150
1.30
12.99
1.45
14.52
1.61
16.06
1.76
17.58
1.91
19.12
200
2.31
23.09
2.58
25.82
2.85
28.55
3.13
31.26
3.40
33.99
250
3.61
36.08
4.03
40.34
4.46
44.61
4.88
48.85
5.31
53.10
300
5.19
51.95
5.81
58.09
6.42
64.23
7.03
70.34
7.65
76.47
350
7.07
70.71
7.91
79.07
8.74
87.43
9.57
95.74
10.41
104.1
400
9.24
92.35
10.33
103.3
11.42
114.2
12.50
125.0
13.59
135.9
450
11.69
116.9
13.07
130.7
14.45
144.5
15.83
158.3
17.21
172.1
500
14.43
144.3
16.14
161.4
17.84
178.4
19.54
195.4
21.24
212.4
600
20.78
207.8
23.24
232.4
25.69
256.9
28.14
281.4
30.59
305.9

 
 

DN
1.2 MPa
1.3 MPa
1.4 MPa
1.5 MPa
1.6 MPa
6
3.333.0Kg/h
3.535.5Kg/h
3.837.9Kg/h
4.040.3Kg/h
4.342.8Kg/h
8
5.958.7 Kg/h
6.363.1 Kg/h
6.767.4Kg/h
7.271.7 Kg/h
7.676.1 Kg/h
10
9.291.7 Kg/h
9.998.5 Kg/h
10.5105.3 Kg/h
11.2112.1 Kg/h
11.9118.8 Kg/h
15
20.6206 Kg/h
22.2222 Kg/h
23.7237 Kg/h
25.2252 Kg/h
26.7267 Kg/h
20
36.7367 Kg/h
39.4394 Kg/h
42.1421 Kg/h
44.8448 Kg/h
47.5475 Kg/h
25
57.3573 Kg/h
61.6616 Kg/h
65.8658 Kg/h
70.0700 Kg/h
74.3743 Kg/h
32
93.9939 Kg/h
1011009 Kg/h
1081078 Kg/h
1151147 Kg/h
1221217 Kg/h
40
1471468 Kg/h
1581577 Kg/h
1681685 Kg/h
1791793 Kg/h
1901901 Kg/h
50
0.23
2.29
0.25
2.46
0.26
2.63
0.28
2.80
0.30
2.97
65
0.39
3.88
0.42
4.16
0.44
4.45
0.47
4.73
0.50
5.02
80
0.59
5.87
0.63
6.31
0.67
6.74
0.72
7.17
0.76
7.61
100
0.92
9.17
0.99
9.85
1.05
10.53
1.12
11.21
1.19
11.88
125
1.43
14.34
1.54
15.40
1.65
16.45
1.75
17.51
1.86
18.57
150
2.06
20.64
2.22
22.17
2.37
23.69
2.52
25.21
2.67
26.74
200
3.67
36.70
3.94
39.42
4.21
42.12
4.48
44.82
4.75
47.53
250
5.73
57.34
6.16
61.59
6.58
65.81
7.00
70.03
7.43
74.27
300
8.26
82.57
8.87
88.69
9.48
94.77
10.08
100.8
10.69
106.9
350
11.24
112.4
12.07
120.7
12.90
129.0
13.73
137.3
14.56
145.6
400
14.68
146.8
15.77
157.7
16.85
168.5
17.93
179.3
19.01
190.1
450
18.58
185.8
19.95
199.5
21.32
213.2
22.69
226.9
24.06
240.6
500
22.94
229.4
24.64
246.4
26.32
263.2
28.01
280.1
29.71
297.1
600
33.03
330.3
35.48
354.8
37.91
379.1
40.34
403.4
42.78
427.8

 
B、测量过热蒸汽流量范围
(口径DN:mm,流量单位:t/h)

DN
6
8
10
15
20
25
32
40
50
65
Qmin
0.5ρ
Kg/h
0.9ρ
Kg/h
1.4ρ
Kg/h
3.1ρ
Kg/h
5.64ρ
Kg/h
8.82ρ
Kg/h
14.4ρ
Kg/h
22.6ρ
Kg/h
35.3ρ
Kg/h
59.7ρ
Kg/h
Qmax
5.0ρ
Kg/h
9.0ρ
Kg/h
14ρ
Kg/h
31ρ
Kg/h
56.4ρ
Kg/h
88.2ρ
Kg/h
144ρ
Kg/h
226ρ
Kg/h
353ρ
Kg/h
597ρ
Kg/h
DN
80
100
125
150
200
250
300
350
400
450
Qmin
0.09ρ
0.14ρ
0.22ρ
0.31ρ
0.56ρ
0.88ρ
1.27ρ
1.79ρ
2.26ρ
2.86ρ
Qmax
0.9ρ
1.4ρ
2.2ρ
3.1ρ
5.6ρ
8.8ρ
12.7ρ
17.9ρ
22.6ρ
28.6ρ
DN
500
600
700
800
900
1000
1100
1200
1400
1600
Qmin
3.53ρ
5.08ρ
6.92ρ
9.04ρ
11.4ρ
14.1ρ
17.1ρ
20.3ρ
27.7ρ
36.1ρ
Qmax
35.3ρ
50.8ρ
69.2ρ
90.4ρ
114ρ
141ρ
171ρ
203ρ
277ρ
361ρ

注:ρ—工作状态下过热蒸汽密度(Kg/m3),可查过热蒸汽密度表求得
 
C、测量液体(水)流量范围
(口径DN:mm,流量单位:/m3/h)

DN
6
8
10
15
20
25
32
40
50
65
Qmin
50l/h
90l/h
140l/h
0.31
0.56
0.88
1.4
2.2
3.5
5.9
Qmax
508l/h
904l/h
1.4
3.1
5.6
8.8
14
22
35
59
DN
80
100
125
150
200
250
300
350
400
450
Qmin
9.0
14.1
22
31.8
56.5
88.3
127.2
173.1
226.1
286.1
Qmax
90
141
220
318
565
883
1272
1731
2261
2861
DN
500
600
700
800
900
1000
1100
1200
1400
1600
Qmin
353.2
508.7
692.3
904.3
1144.5
1413
1709.7
2034.7
2769.4
3617.2
Qmax
3532
5087
6923
9043
11445
14130
17097
20347
27694
36172

 
D、测量气体流量范围
 
D.1测量气体工况流量范围              (口径DN:mm,流量单位:/m3/h)

DN(mm)
6
8
10
15
20
25
32
40
50
Qmin
m3/min
0.0083
0.015
0.023
0.052
0.094
0.15
0.24
0.38
0.59
m3/h
0.5
0.9
1.41
3.1
5.6
9.0
14.4
22.8
35.4
Qmax
m3/min
0.083
0.15
0.23
0.52
0.94
1.5
2.4
3.8
5.9
m3/h
5.08
9.04
14.1
31.2
56.4
90
144
228
354
DN(mm)
65
80
100
125
150
200
250
300
350
Qmin
m3/min
1.0
1.53
2.36
3.68
5.3
9.42
14.7
21.2
28.9
m3/h
60
91.8
141.6
220.8
318
565.2
882
127.2
173.4
Qmax
m3/min
10
15.3
23.6
36.8
53
94.2
147
212
289
m3/h
600
918
1416
2208
3180
5652
8820
1272
1734
DN(mm)
400
450
500
600
700
800
900
1000
1200
Qmin
m3/min
37.7
47.7
58.9
84.8
115.6
150.8
190.8
235.6
339.1
m3/h
2262
2862
3534
5088
6936
9048
11448
14136
20346
Qmax
m3/min
377
477
589
848
1156
1508
1908
2356
3391
m3/h
22620
28620
35340
50880
69360
90480
114480
141360
203460

 

 

对上下游直管道的要求
为了保证仪表能正常工作,传感器安装点上下游必须有一定长度的直管道,用于减弱消除管道阻流件造成的干扰旋涡,使流动趋于平稳,安装前后直管道如下表:

阻流件形式
上游直管道长度
下游直管道长度
上游缩管时
≥15D
 
≥5D
上游扩管时
 
≥35D
≥5D
 
上游有一个弯头时
 
≥40D
≥5D
 
上游同一平面有二个弯头时
≥40D
≥5D
 
上游不同平面有二个弯头时
≥40D
≥5D
 
上游全开球阀
≥50D
≥5D
上游调节阀
调节阀应该装在流量计的下游(≥5D)         
注:当直管道不够长时,一般要保证前10D5D的要求,否则要加装整流器

主要技术参数
1、测量流体:过热蒸汽、饱和蒸汽、压缩空气、水以及其他常见气体和液体
2、准确度等级:±1.0%(液体),±1.5%(气体)
3、额定压力(可选择):1.6Mpa2.5Mpa4.0Mpa
4、流体温度:—40℃——+440℃
5、工作电源:外接交流220V,外接直流24V,内置干电池(可连续工作2年);
6、输出信号(可选择);频率:4-20mA,RS-485,HART协议
7、电器接口:M20X1.5
8、防护等级:IP65
9、环境温度:—40℃——+60℃(无LCD),0℃——+60℃(带LCD)
10、与工艺管道连接(可选择):法兰夹装,法兰连接或螺纹连接(定做)
11、安装方式(可选择):水平、垂直、倾斜、倒装
12、防爆标志:ExdⅡBT3-6
上一篇: 差压流量计数值不稳定是什么原因 下一篇: 高温烟气 蒸汽流量测量及怎么用温压补偿