科瑞文KRIWAN电机马达控制器 INT89 U Diagnose 22 A 637 S021 (22 A 637 S021)
品牌
生产厂家厂商性质
上海所在地
TECSYSTEM 智能温控器 PTC传感器模拟器 PTC SIMULATOR (PTC SIMULATOR)
面议TECSYSTEM 智能温控器 PT100传感器模拟器 PT100 SIMULATOR (PT100 SIMULATOR)
面议TECSYSTEM 智能温控器 PT73-220 (PT73-220)
面议TECSYSTEM 智能温控器 CONV 8/420/A (CONV 8/420/A)
面议TECSYSTEM 智能温控器 CONV 4/420/A (CONV 4/420/A)
面议TECSYSTEM 智能温控器 CONV 232/485 (CONV 232/485)
面议TECSYSTEM 智能温控器 BUSMOD 8/A (BUSMOD 8/A)
面议TECSYSTEM 智能温控器 AU24 (AU24)
面议TECSYSTEM 智能温控器 AU12 (AU12)
面议TECSYSTEM 高压大功率电力变压器用智能温控器 BWD-3KRL (BWD-3KRL)
面议TECSYSTEM 高压大功率电力变压器用智能温控器 NT579 (NT579)
面议TECSYSTEM 高压大功率电力变压器用智能温控器 TPL503 (TPL503)
面议Application | Extended service life of system due to temperature and current monitoring |
Supply voltage | AC 115-240V |
Permitted ambient temperature | -30...+70°C |
Reset delay: Overvoltage | 1min ±6s |
Reset of reset delay | Main reset >5s only possible if there is no error current |
Relay: Connection | 240V ~ 2.5A C300Min. 24V ~ / 20mA |
Relay: Mechanical service life | Approx. 1 million switching cycles |
Interface | Diagnose port (DP) |
Protection class acc. To EN 60529 | IP00 |
Connection type | 6.3mm flat plugs |
Housing material | PA glass-fibre-reinforced |
Mounting | Screw mounted |
Dimensions | See dimensions in mm |
Weight | Approx. 200g |
Check base | EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2 |
Mains voltage monitoring: Monitoring range 1 | AC 110-120V |
Mains voltage monitoring: Monitoring range 1, Mains voltage recognition | ≤150V |
Mains voltage monitoring: Monitoring range 1, Accuracy | ±5% of the measuring range |
Mains voltage monitoring: Monitoring range 1, Undervoltage preliminary warning | <103V |
Mains voltage monitoring: Monitoring range 1, Undervoltage shutdown | <98V |
Mains voltage monitoring: Monitoring range 1, Overvoltage preliminary warning | >127V |
Mains voltage monitoring: Monitoring range 1, Overvoltage shutdown | >132V |
Mains voltage monitoring: Monitoring range 2 | AC 220-240V |
Mains voltage monitoring: Monitoring range 2, Mains voltage recognition | >150V |
Mains voltage monitoring: Monitoring range 2, Accuracy | ±5% of the measuring range |
Mains voltage monitoring: Monitoring range 2, Undervoltage preliminary warning | <187V |
Mains voltage monitoring: Monitoring range 2, Undervoltage shutdown | <177V |
Mains voltage monitoring: Monitoring range 2, Overvoltage preliminary warning | >244V |
Mains voltage monitoring: Monitoring range 2, Overvoltage shutdown | >265V |
Reset delay: Undervoltage | 1min ±6s |