品牌
生产厂家厂商性质
苏州市所在地
TREK511手持式静电压测试仪便携手掌型静电场强计TREK-511美国进口
面议无尘笔记本A4 A5 A6 50页 32页 20页 防静电净化笔记本
面议无尘净化打印纸复印纸CLEANTEK
面议无尘擦拭纸木浆纸0609,0606,0604
面议超细纤维无尘布CLN-4004
面议SL-028斯莱德卧式离子风机*苏州生产台式离子风机单头多头
面议FPD-8010E|FPD-8010-E压力图像量化分析系统软件j日本富士感压纸压力胶片
面议4LW|LLLLW极超级低压微压(0.05~0.2MPA)富士压敏纸感压纸感压膜感压胶片
面议连体服防静电服无尘服连帽连裤披肩帽连体分体服大褂
面议接地系统监测报警仪SL-038
面议SL-033单脚单通道人体综合测试仪
面议SL-032单脚双通道人体综合测试仪静电环静电鞋测试仪苏州生产
面议美国 TREK 520手持式静电电压测试仪
特点:
TRE-520:0~±2KVDC
TRE-523:0~±20KVDC
精准度±5%, 具备Hold功能
应用: 人体或对象表面静面量测试,主要用于厂内静电产生情况的抽检
Model 520 Series HAND-HELD Electrostatic Voltmeter
The Model 520 Series includes the Model 520 and Model 523.
The TREK Model 520 Hand-Held Electrostatic Voltmeter (ESVM) Series products provide accurate, noncontacting measurements of electrostatic surface voltage for ESD applications in either ionized or non-ionized environments. Industrial applications include measuring charge accumulation in the LCD manufacturing process or measuring static charge in semiconductor production. The Model 520 series ESVMs utilize a new measurement technique that overcomes the disadvantage of the typical hand-held fieldmeter by providing surface voltage measurements which are essentially independent of the sensor probe-to-measured surface spacing.
Model:520-1 ESVM
Over a spacing range of 5 mm to 25 mm, the 520 voltmeter provides better than a 5% voltage measurement accuracy, while the typical fieldmeter provides a voltage measurement error in excess of 50%. An optional voltage monitor output is available (Model:520-2).
Model 523 ESVM
Over a spacing range of 30 mm to 60 mm, the 523 voltmeter provides greater than a 5% voltage measurement accuracy, while the typical fieldmeter provides a voltage measurement error in excess of 50%.
The 520 series provides a measurement system which complies with standardized calibration equipment traceable to the National Institute of Standards and Technology. The 520 series hand-held voltmeters employ a slender sensor probe design that provides flexibility to make measurements in many locations which are impossible to reach using the large, bulky sensing surfaces of the typical hand-held fieldmeter. The slender design also allows for higher spatial resolution capability by allowing the measurement of small surface areas. A "hold" pushbutton retains the displayed measured voltage value for recording purposes.
· Model:520 Measurement Range
0 to ±2 kV DC.
Model 523 Measurement Range
0 to ±20 kV DC.
Model:520 Accuracy
ESVM Monitor (Model:520-2)
Better than ±5% of full scale over the entire recommended probe-to-surface separation range of 5 mm to 25 mm.
Model 523 Accuracy
Better than ±5% of full scale over the entire recommended probe-to-surface separation range of 30 mm to 60 mm.
Model:520 Probe-to-Surface Separation (recommended)
5 mm to 25 mm.
Model 523 Probe-to-Surface Separation (recommended)
30 mm to 60 mm.
Stability
Drift with Time
Less than 600 ppm/hour, noncumulative.
Drift with Temperature
Less than 600 ppm/°C.