液体涡轮流量计量程范围表
时间:2010-01-27 阅读:5011
液体涡轮流量计的流量范围见下表:
公称 通径 Dn (mm) | 流 量 范 围 | 公称 压力 PN (Mpa) | zui大 压力 损失 (Mpa) | | |||||
基本误差限 ±0.2% | 基本误差限 0.5% | 基本误差限 1.0% | |||||||
下限 | 上限 | 下限 | 上限 | 下限 | 上限 | | |||
2* | - | - | - | - | 0.010 | 0.130 | 1.6 | 0.15 | |
3* | - | - | - | - | 0.040 | 0.250 | 1.6 | 0.12 | |
4* | - | - | - | - | 0.04 | 0.25 | 6.3 | | |
6 | | | 0.1 | 0.6 | 0.1 | 0.6 | 6.3 16* 25* 25 40* | 0.08 | |
10 | | | 0.25 | 1.2 | 0.2 | 1.2 | | ||
15 | 1.2 | 5 | 0.6 | 4 | 0.5 | 5 | | ||
20 | 1.5 | 7 | 1.1 | 7 | 0.7 | 7 | | ||
25 | 2 | 10 | 1.6 | 10 | 1 | 10 | 0.04 | | |
32 | 3.2 | 16 | 2.5 | 16 | 1.6 | 16 | 2.5 2.5 2.5 2.5 2.5 | | |
40 | 4 | 20 | 3 | 20 | 2.5 | 25 | | ||
50 | 8 | 40 | 4 | 40 | 4 | 40 | | ||
65 | 12 | 60 | 6 | 60 | 6 | 60 | | ||
80 | 20 | 100 | 10 | 100 | 10 | 100 | | ||
100 | 25 | 160 | 20 | 160 | 20 | 200 | 1.6或2.5 | | |
150 | 50 | 300 | 40 | 300 | 40 | 400 | | ||
200 | 120 | 600 | 100 | 600 | 80 | 800 | 1.6 | | |
250* | 200 | 1000 | 160 | 1000 | 120 | 1200 | | ||
300* | | | 250 | 1600 | 180 | 1800 | |
注:“*”为特殊定货,
公称通径为2mm的,流量范围0.040~0.13m3/h时基本误差:±1%读数的,≤0.040m3/h时基本误差:±1%满度值的。
公称通径为3mm的,流量范围0.085~0.250m3/h时基本误差:±1%读数的,
≤0.085m3/h基本误差:±1%满度值的。
表中所示流量范围为常规值,如有需要可根据用户要求作适度扩展,其zui低流速可扩展至0.3m/s左右,有的规格可更低些,其扩展区域内的精度按满度值的相对误差表示。
l 被测量介质:液体(避免多相流)
l 介质粘度范围:≤5mPɑ·S
l 标定:出厂前用水标定