EQUOPEN笔式硬度计
面议便携里氏硬度仪
面议FERITSCOPE? FMP30 焊接和电镀材料
面议A Sealing Quality Tester for anodi纳米硬度计
面议POROSCOPE? HV20(D)微纳米硬度计
面议SIGMASCOPE? SMP10系列微纳米硬度计
面议PICODENTOR? HM500纳米硬度计
面议FISCHERSCOPE? HM2000系列微纳米硬度计
面议FERITSCOPE? FMP30 焊接和电镀材料
面议材料分析-FISCHERSCOPE? GOLDLINE ASSAY
面议COULOSCOPE? CMS和CMS STEP(库仑仪)
面议手提式仪器-特殊应用
面议The EPOCH XT incorporates many standard measurement features including a tunable square wave pulser, selectable narrow-band and broad-band digital filters, gain range from 0 to 110 dB, peak memory and peak hold, adjustable PRF, 0.001 in. (0.01 mm) measurement resolution, and two gates with programmable alarms. In addition, the unit offers many standard and optional application-specific software features: Dynamic DAC/TVG (Distance Amplitude Correction/ Time Varied Gain), On-board DGS/AVG, AWS D1.1 & D1.5, Curved Surface Correction, and GageView Pro.
The EPOCH XT offers three battery options that provide long-lasting battery operating time depending on display brightness and battery selection.
The rugged EPOCH XT is designed to meet the requirements of IP67. The instrument can withstand the rigors of field operation in harsh environments from offshore to deserts.
The optional GageView Pro Interface Program helps manage and format stored inspection data. Data can be printed or easily copied and pasted into word processing files and spreadsheets for further reporting needs. The GageView Pro Interface Program also allows the creation of a customized database of identifier (ID) strings that can be uploaded to the EPOCH XT. New features include remote display of live EPOCH XT screen on a PC, live screen capture mode, database backup/restore, and multi-view windows. The Interface Program is fully compatible with the EPOCH 4, 4B, 4PLUS, LT, and XT.
The EPOCH XT's sophisticated datalogger is designed for ease of use while providing a wide range of features for many flaw detection and thickness gaging applications. Employing both EPOCH 4 series and the Panametrics-NDT corrosion thickness gage technologies, the EPOCH XT is ready to meet your inspection and thickness measurement survey requirements.
File types to meet your needs:
The EPOCH XT also offers onboard report generation. Operators may set up custom report headers and print directly from the instrument using the USB Host Port.
General |
EN12668-1 Compliant |
Weight: 4.7lbs (2.1kg) with Li Battery |
Dimensions: 10.9" H x 5.9" W x 2" D (at hand), 2.8" (at display); 277 mm x 150 mm x 51 mm (at hand), 71 mm (at display) |
Keypad: English, International, Japanese or Chinese |
Languages: English, Spanish, French, German, Italian, Japanese, Chinese, Russian, Korean, Norwegian, Swedish. Custom languages available. |
Transducer Connections: BNC or Number 1 LEMO (BNC rated to IP67) |
Battery: Choice of Lithium Ion, Nickel Metal Hydride, and Alkaline C-Cells |
Battery Operating Time: Lithium Ion: 9-10 Hours, NiMH: 5 Hours, C-Cells: 1-2 Hours |
Power Requirements: AC Mains: 100-120 VAC, 200-240 VAC, 50-60 Hz |
Environmental Ratings |
IP67 Designed to meet the requirements of Environmental Ingress Protection Rating** |
Explosive Atmosphere approved per MIL-STD-810F, Procedure 1, NFPA 70E, Section 500, Class 1, Div. 2, Group D |
Shock tested per IEC 60068-2-27, 60g's, 6msec H.S., 3 axes, 18 total |
Vibration Tested - Sine Vibration per IEC 60068-2-6, 50-150 Hz @ .03" DA or 2g's, 20 sweep cycles |
Display |
Color Liquid Crystal display with 60 Hz update, user-selectable color schemes and brightness, and split screen and full screen modes. |
Display Dimensions: 320 Pixels (W) x 240 Pixels (H) Color 4" W (101 mm) x 3" H (75 mm) |
Baseline Break Mode: All zero cross points on the RF waveform are shown as zero points in Fullwave mode. |
Amplitude Grid Modes: or 110% Amplitude Display |
Time Base Grid Modes: Standard 0 to 10 division, Soundpath Mode divides Range into 5 equal sections with grid lines, Leg Mode displays Soundpath Legs as grid lines |
Pulser |
Tunable Square Wave Pulser |
PRF: User Selectable or Auto from 10 Hz to 1000 Hz |
Energy Settings: 50 to 475 V in 25 V increments |
Pulse Width: Adjustable from 30 to 10,000 ns (0.1 MHz) with PerfectSquare™ Technology |
Damping: 50, 63, 150, 400 Ohms |
Receiver |
Gain: 0 to 110 dB - Two user-defined gain step adjustments and presets above function keys. |
Total Instrument Bandwidth: 0.2 - 26.5 MHz @ -3 dB |
Digital Filter Settings: • 0.2 - 10.0 MHz • 2.0 - 21.5 MHz • 0.2 - 1.2 MHz • 5.0 - 15.0 MHz • 0.5 - 4.0 MHz • 8.0 - 26.5 MHz • 1.5 - 8.5 MHz |
Rectification: Fullwave, Positive Halfwave, Negative Halfwave, RF |
System Linearity: Horizontal: +/- 0.2% FSW |
Vertical: 0.25% FSH, Amplifier Accuracy +/- 1dB |
Reject: 0 to 80% full screen height with visual warning |
Calibration |
Automated Distance Calibration for Velocity and Zero Offset |
Test Modes: Pulse Echo, Dual, or Through Transmission |
Units: Millimeters, Inches, or Microseconds |
Range: 0.073 to 527" (1.86 to 13,400 mm) |
Velocity: 0.025 to 0.6000 in/µsec (635 to 15240 m/S) |
Zero Offset: 0 to 4950 µsec |
Display Delay: -2.323" to 500" (-59 mm to 12700 mm) |
Refracted Angle: 10° to 85° in 0.1° resolution |
Measurements |
Types: Thickness, Soundpath, Projection, Depth, Amplitude, Time-Of-Flight for both Gate 1 and Gate 2. |
Echo-To-Echo: Standard. |
Five Measurement Display Locations: User selects up to five measurements from either gate to display on the live screen. |
DAC/TVG Standard: Up to 50 points captured, ASME, ASME III, JIS, 80-20%, CUSTOM DAC, and TVG Table. 110dB Dynamic Range, 100dB per usec adjustment, full gain, range, and delay adjustments during setup, view switchable between DAC/TVG. |
CUSTOM DAC with up to three warning curves from +10 dB to -24 dB |
TVG Table setup for advanced Time Varied Gain applications. Also allows TVG setups to be built from DGS/AVG diagrams. |
Amplitude Measurement: 0 to 110% full screen height with 0.25% resolution Curved Surface Correction for Angle Beam measurements standard X-Value Correction for distance from Beam Index Point to front of transducer. |
Gates |
Two Fully Independent Gates for Echo Height and Time-Of-Flight. |
Gate Start: Variable over entire displayed range |
Gate Width: Variable from Gate Start to end of displayed range |
Gate Height: Variable from 2 to 95% Full Screen Height |
Alarms: Positive and Negative Thresholds; Minimum Depth on Gate 1 and Gate 2 |
Zoom: Displayed Range is Gate 1 Width |
Instrument Inputs / Outputs |
USB Client Port: For communication with GageView Pro |
USB Host Port: Allows direct printing to any PCL5 compatible Laser or Inkjet printer as well as data storage on USB drives. |
LEMO Hardware I/O (optional): Alarm Outputs, Trigger In/Out |
Data Storage |
Up to 10,000 IDs with Waveforms, Measurements, and Setup Parameters |
Warranty
One year limited warranty.
Standard Inclusions
EPOCH XT Base Instrument Includes:
- EP4/MCA: AC Adaptor
- EPXT-TC: Transport Case
- EPXT-MAN: Instrument Operating Manual
- EPXT-HS: Bi-Directional Hand Strap
- EPXT-PS: Rubber Coated Stainless Steel Pipe Stand
- Lithium Ion or Nickel Metal Hydride Battery
- Cap(s) for transducer connectors
Optional Accessories
- EPXT-EC: External Smart Battery Charger
- EP4/CH: Chest Harness
- EPXT-RPC: Rubber Protective Case
- EPXT-DP: Clear Display Protectors (10)
- EPXT-C-16HW-6: 16 pin Hardware I/O cable with diagram
- EPXT-HWIO-B, L: Hardware I/O option
- EPXT-SEAL-KIT: Set of O-Rings and membrane
- EPXT-EW: Extended Warranty for one additional year.
Software Options
DGS/AVG (PN: EPXT-DGS-AVG)
AWS D1.1/D1.5 (PN: EPXT-AWS)
GAGEVIEW PRO (PN: GAGEVIEWPRO-KIT-USB)
*All specifications are subject to change without notice.
** The EPOCH XT has been designed to meet the requirements of IP67 to ensure that it is suitable for use in harsh environments. The customer replaceable instrument gaskets for the battery door and I/O access door must be properly maintained to ensure the effective sealing over the life of the product.