Windows98/Me/2000/XP correspondence
GP-IB, RS-232C and software for making
attenuation program are standard accessories.
Optimum for evaluation of communication quality of
such wireless communication equipments as W-CDMA,
CDMA, GSM, PDC, PHS, ETC, wireless LAN and Bluetooth.
MAT800 is a multi-functional and all-out programmable attenuator that is capable of controlling the attenuation of microwave signal at an ultra-high speed.
◆Features
1. The arbitrary attenuation programs is possible
*128kwords built-in program memory
*Maximum 2µs switching (readout) speed
*Three readout modes of FREE, BURST and GATE
*Setup of hold off period by the number of clocks or by time
2. The software for making attenuation program is a standard accessory
3. GP-IB and RS-232C are equipped as standard accessories
4. Four models are prepared for every frequency band
*model A : 1.5 to 4.5GHz
*model B : 3.0 to 9.0GHz
*model C : 4.5 to 13.5GHz
*model D : 1.95 to 5.85GHz
5. The maximum attenuation is 80dB
6. The minimum step size of attenuation is 0.05dB
1. Attenuation mode | 2. Attenuation |
Select either manual setup or programmed setup. * Refer to "Setting of attenuation". | Set the attenuation. It is valid in the manual mode. 0 to 80 dB in 0.05 dB steps. |
3. Filter | 4. Readout clock |
Select switching response time of attenuator. * Refer to "About a filter". | Set readout clock of program memory. External clock and manual clock are available. |
5. Program length | 6. Program hold off period |
Set program memory length. 8 to 131,072 words in one word step. | Set hold off period of program memory, that is, the time till the next readout is started. Perform setup by number of readout clocks or by time. * Refer to "Setting of attenuation". |
7. Readout mode | 8. Setup |
Set readout method of program memory from Free, Burst and Gate. * Refer to "Program readout mode". | Set parameters of RS-232C or GP-IB. |
9. External readout clock | 10. Trigger input |
Connector for input of external clock for reading program memory. | Connector for input of trigger signal for such read mode as Burst or Gate. * Refer to "Program readout mode". |
11. SYNC output | 12. Attenuator input / output |
A signal synchronized with the top address of the program memory is output. * Refer to "Program readout mode". | SMA connector for attenuator input / output. |
◆Setting of attenuation
Two methods are available for setup of attenuation ; manual or program. Select one by "ATTEN MODE".
●Manual mode
Set the attenuation using the rotary encoder on the front panel. Alternatively, perform setup from outside using RS-232C or GP-IB. The setup parameters in manual mode are attenuation and filter only.
| M | A | N | U | A | L | | | | | | 2 | 3 | . | 4 | 5 | d | B | |
| | | | | | | | | | | | | | | 3 | 0 | µ | s | |
●Program mode
Read the memory storing attenuation data transferred from the computer. There are five parameters in the program mode ; readout clock, program length, hold-off period, readout mode and filter.
P | R | G | M | | | 1 | 0 | k | H | z | | L | : | 1 | 3 | 1 | 0 | 7 | 2 |
P | : | 6 | . | 5 | 5 | 3 | 5 | s | | | F | R | E | E | | 3 | 0 | µ | s |
The program readout period is the period from address 0 of the memory to address n (set by program length). The program length can be set between 8 and 131072 words in one word step. When the program is read up to address n, the attenuation data at address n is held for the hold off period (set by number of readout clocks or by time), and on termination of hold off period, the memory is read out from address 0 again.
About a filter
CR filter is inserted in the attenuation controlling line. Use when it is required to smooth the change at the moment of switching attenuation. However, it is necessary to pay attention to the relation with the readout clock. An appropriate filter value is normally 1 / 2 to 1 / 8 of the clock period.
◆The method of a program
When it is necessary to use the program mode, input the program (waveform) on a Windows computer using "Software for making attenuation program", which is provided as a standard accessory. Then transfer this attenuation data to the memory of MAT800 using RS-232C or GP-IB. Readout clock, program length, hold off period, readout mode and filter are set from the computer. Of course it is possible to set by keys on the front panel. Connect external clock and trigger signal as required.
● Waveform creation
1. Standard waveforms input
The nine types of standard waveforms are prepared. They are sine wave, ******** wave, square wave, ramp wave, sinX / X, (1-ε-ax), ε-ax white noise and DC.
2. Straight line input
Two specified points are linked together by means of a straight line.
3. Arithmetic calculation input
A waveform is created by arithmetic calculation of addition, subtraction, clipping, absolute, mirror, smoothing, resize and offset.
4. One-point input
A waveform is created through input of one point at a time.
● Waveform editing and file management
Waveform editing and file management may be performed using CUT, COPY, PASTE and UNDO.
◆Program readout mode
Three program readout modes are available ; Free, Burst and Gate. Readout is executed regardless of the trigger signal in the Free mode. In the Burst mode, the readout of program memory is started at the rising edge of the trigger signal, the attenuation data of the terminating address is held until the next activation. Therefore, setup of the hold off period is not permitted in the Burst mode.
In the Gate mode, one set of the readout of program memory and hold off period is repeated while the trigger signal is of a high level. The last attenuation data is held when the trigger signal goes down to a low level and then address n of program memory is read out.
◆Application - wireless communication quality test by changing transmission power
With wireless communication equipments, W-CDMA, CDMA, GSM, PDC, PHS, ETC, wireless LAN and Bluetooth, the transmission power changes due to obstacles and multi-paths besides theoretical space losses, when the radio wave is transmitted through the space. This changing pattern can be simulated using MAT800 and the communication quality can be evaluated. This changing pattern can be easily created using "Software for making attenuation program". It will be very convenient if our "Shielding box ME8661A" is used for this test.
◆Specification
| model A | model B | model C | model D |
Frequency range | 1.5 to 4.5GHz | 3.0 to 9.0 GHz | 4.5 to 13.5GHz | 1.95 to 5.85GHz |
VSWR | < 1.5 @ 2 to 4GHz < 2.0 @ 1.5 to 4.5GHz | < 1.7 @ 4 to 8GHz < 2.2 @ 3 to 9GHz | < 1.8 @ 6 to 12GHz < 2.2 @ 4.5 to 13.5GHz | < 1.6 @ 2.6 to 5.2GHz < 2.1 @ 1.95 to 5.85GHz |
Insertion loss (0dB setting) | < 2.3dB @ 2 to 4GHz < 2.6dB @ 1.5 to 4.5GHz | < 3.0dB @ 4 to 8GHz < 3.3dB @ 3 to 9GHz | < 3.5dB @ 6 to 12GHz < 3.8dB @ 4.5 to 13.5GHz | < 2.6dB @ 2.6 to 5.2GHz < 2.9dB @ 1.95 to 5.85GHz |
Attenuator Setting range Setting resolution Accuracy (at center of frequency range and +10dBm input) Impedance Filter Maximum input level Input damage level Input / output connector Readout clock input Input level Maximum frequency Input impedance Minimum pulse width Input damage level Connector Trigger input Input level Input impedance Minimum pulse width Input damage level Connector SYNC output Output level Rise / Fall time Output impedance Connector | 0 to 80dB less than 0.05dB less than ±0.5dB @ 0 to 10dB less than ±0.8dB @ >10 to 30dB less than ±1.0dB @ >30 to 50dB less than ±1.5dB @ >50 to 64dB less than ±2.0dB @ >64 to 74dB less than ±3.0dB @ >74 to 80dB 50ohm nominal 1µs to 3ms, 1-3 step 100mW @ CW or peak power 0.8W @ average power 20W @ peak power of 1µs pulse SMA TTL level 500kHz 10kohm ±5% more than 200ns (both of high and low) ±20V (DC + ACpeak) max BNC TTL level 10kohm ±5% more than 1µs ±20V (DC + ACpeak) max BNC TTL level less than 100ns approx. 100ohm BNC |
◆Functions
Attenuation mode Program mode Program length Readout clock Internal clock External clock Manual clock Hold off period Clock setting Time setting Read mode Backup of program | Manual and Program 8 to 131072words, (available for setting in one word step) 100Hz to 500kHz, 1-2-5 step DC to 500kHz Due to pressing ENTER key 0 to 65535 clocks of readout clock (available for each clock) 0 to 6.5535sec (by 100µs step) Free, Burst, Gate Program data is automatically saved when turning off. |
◆Software for making attenuation program
Effective OS Making waveform Standard waveform Waveform type Parameter Straight line Calculation One point input Editing of waveform File | Windows95 / 98 / Me / 2000 / XP Sine, Triangle, Square, Ramp, sinX / X, (1-ε-ax), ε-ax, White noise and DC Data size, Attenuation (except DC), Offset, Cycle (except White noise and DC), Phase (°) (except White noise and DC), Duty ratio (%) (only Square wave), Zero cross (only sinX / X), Attenuation ratio ( (1-ε-ax) and ε-ax) Link two points with line +, -, ×, Clipping, Absolute, Mirror, Smoothing, Resize, Offset Input each point Cut, Copy, Paste, Undo, Delete New, Open, Close, Save, Save as, Data import, Data export, Print, Printer setup, Transmit, Exit |
◆Others
Display Interface RS-232C Baud rate GP-IB Address | LCD (20characters × 2columns) Standard Accessory 2,400 to 57,600 Standard Accessory 0 to 30 |
◆General
MICRONIX Corporation receives the right to make changes in design, specification and other information without prior notice.
Operating temperature Operating humidity Storage temperature Power Supply Weight Dimensions Standard accessories | 0 to 40°C (Guaranteed at 23 ±5°C) less than 40°C / 80%RH (Guaranteed at less than 28°C / 80%RH) -10 to +60°C / less than 80%RH 90 to 132VAC / 180 to 250VAC (selectable by a switch located on rear panel) approx. 4.5kg 260 (W) × 115 (H) × 360 (D) mm (excluding projections) Instruction manual (1pc), Power cable (1pc), Fuse (1pc), FD for making attenuation program (1pc), RS-232C cable (1pc) |
◆Optional
GP-IB cable Coaxial cable Coaxial cable Coaxial cable Fixed microwave attenuators 50 ohm termination | MI200 MC201 MC202 MC203 (1 to 10, 12, 13, 15, 20dB) (SMA) |