产品简介
wideplus-Intelligent digital/light column display controller
详细介绍
wideplus-Intelligent digital/light column display controller
Intelligent digital/light column display control instrument adopts advanced microprocessors for intelligent control, and it is suitable for display and control for various physical quantity check signals, such as temperature, humidity, pressure, liquid level, instantaneous flow, speed and so on, as well as can carry out the linear calibration with high accuracy for various non-linear input signals. Adoption of up-to-day non-jumper technique makes the input port to gain universal signal input function. Users can realize light switching between multi-input-signals (various thermocouples, thermo-resistance, standard voltage / current signal) only need by changing internal parameters, so has improved the universality and reliability of instrument. Instruments adopt high brightness LED digital display and high-resolution light column display (proportion display) make measurement/control value display more clear and visual. Input and output loops all adopt photoelectric isolation; its anti-interference ability is strong. It may with serial communication interface, can carry out both-way communication between it and every device with serial interface, and constitute network control system. |
Outline dimension and open hole dimension |
|
Outline dimension_8×48×115mm Open hole dimension_5×45mm | Outline dimension_6×48×115mm Open hole dimension_2×45mm | Outline dimension_8×96×115mm Open hole dimension_5×92mm | Outline dimension_2×72×115mm Open hole dimension_8×68mm |
|
|
Outline dimension_6×96×115mm Open hole dimension_2×92mm | Outline dimension_60×80×115mm Open hole dimension_52×76mm | Outline dimension_0×160×115mm Open hole dimension_6×152mm | Outline dimension_0×160×115mm Open hole dimension_6×152mm |
|
Wiring diagram |
| Instrument wiring diagram of 48×48 |
Instrument functional combination | Output function located terminal | 3〿 | 6〿 | Display | × | × | Display +communication | × | communication | Display +communication +transmission | transmission | communication | Display +communication +control | AL1 | communication | Display +communication +P | P | communication | Display +2control | AL1 | AL2 | Display +control + transmission | AL1 | transmission | Display +control +P | AL1 | P | Display +transmission +P | P | transmission | Display +P | × | P |
|
|
| Instrument wiring diagram of 72×72 |
Instrument functional combination | Output function located terminal | 4〿 | 6〿 | 8〿 | Display | × | × | × | Display +communication | × | × | communication | Display +communication +transmission | × | transmission | communication | Display +communication +transmission +control | AL1 | transmission | communication | Display +communication +2position control | AL1 | AL2 | communication | Display +transmission | × | × | transmission | Display +transmission +2 position control | AL1 | AL2 | transmission | Display +2position control | AL1 | AL2 | × | Display +3position control | AL1 | AL2 | AL3 | Display +P | × | P | × | Display +communication +P | × | P | communication | Display +communication +position control +P | AL1 | P | communication | Display + 2position control +P | AL1 | AL2 | P | Display +transmission +position control +P | AL1 | P | transmission |
|
|
| Instrument wiring diagram of 96×96 | Universal type
Double transmission type
|
|
|
| Instrument wiring diagram of 96×48, 48×96 | Universal type
Multiple function type
Double transmission type
| | 40〿0〿0 series universal type different function combination and wiring terminal arrange | Instrument functional combination | Output function located terminal | 3〿 | 5〿 | 7〿 | 9〿0 | Display | × | × | × | × | Display +communication | × | × | × | communication | Display +communication +transmission | × | × | transmission | communication | Display +communication+transmission+2control | AL1 | AL2 | transmission | communication | Display +communication+2position control | AL1 | AL2 | × | communication | Display +communication+3position control | AL1 | AL2 | AL3 | communication | Display +transmission | × | × | × | transmission | Display +transmission+2control | AL1 | AL2 | × | transmission | Display+transmission+3control | AL1 | AL2 | AL3 | transmission | Display +2 position control | AL1 | AL2 | × | × | Display +3 position control | AL1 | AL2 | AL3 | × | Display +4 position control | AL1 | AL2 | AL3 | AL3 | Display +P | × | × | P | × | Display +communication +P | × | × | P | communication | Display +communication +2position control +P | AL1 | AL2 | P | communication | Display +2position +P | AL1 | AL2 | P | × | Display +3position +P | AL1 | AL2 | AL3 | P |
|
|
Type spectrum table |
Model | Explanation | WP- | □□ | ▿/p> | □□ | ▿/p> | □□ | □□ | -▿/p> | ▿/p> | ▿/p> | -▿/p> | | Outline feature | C | | | | | | | | | | Single-screen horizontal type | S | | | | | | | | | | Single-screen vertical type | D | | | | | | | | | | Double screen horizontal type | DS | | | | | | | | | | Double screen vertical type | T | | | | | | | | | | Single-screen single light column vertical type | TX | | | | | | | | | | Single-screen single light column horizontal type | Outline dimension | | 3 | | | | | | | | | 48×48 mm | 4 | | | | | | | | | 96×48 mm, 48×96 mm | 7 | | | | | | | | | 72×72 mm | 8 | | | | | | | | | 160×80 mm, 80×160 mm (may select light column) | 9 | | | | | | | | | 96×96 mm (may select light column) | Control action | | 01 | | | | | | | | Measure display | 03 | | | | | | | | Measure display with upper/lower limit control/alarm | 04 | | | | | | | | Display with four limits control/alarm | 05 | | | | | | | | Display with 5-8 limitation control/alarm (arbitrarily combination) | Communication mode | | 0 | | | | | | | No communication interface | 2 | | | | | | | RS-232C communication interface | 8 | | | | | | | RS-485 communication interface | Output mode | | 0 | | | | | | No output | 1 | | | | | | Relay output | 2 | | | | | | (4ソ0)mA | 3 | | | | | | (0ソ0)mA | 4 | | | | | | (1ソ)V | 5 | | | | | | (0ソ)V | 6 | | | | | | SCR zero-across trigger pulse output | 7 | | | | | | SSR controlled signal output | 8 | | | | | | Special specification transmitting output | 9 | | | | | | Two ways transmission output (when ordering note the output signal, please.) | Input type | | -□□ | | | | | See “input type table‿/p> | The first alarm | | N | | | | No control/alarm | H | | | | High limit alarm | L | | | | Lower limit alarm | The second alarm | | N | | | No control/alarm | H | | | High limit alarm | L | | | Lower limit alarm | Feed output | | P | | DC24 V feed output | Supply power mode | | | AC220 V linear power (may be omitted) | T | AC (90ソ65) V switch power supply | W | DC24 V supply power |
Model example: WP-C801-00-08-N; WP-C403-01-12-HL; WP-T804-81-08-2H2L; WP-C805-01-23-4H4L (This series have only 80 outline that can output most eight alarm points ). |