Bently Nevada 3500/22M Transient Data Interface
品牌
其他厂商性质
深圳市所在地
深圳市大成机电技术有限公司
组合推荐相似产品
Bently Nevada TrendMaster Sensor Systems 200150
Bently Nevada 350500 Pressure Transducer Systems
Bently Nevada 990 Vibration and Thrust Transmitters
Bently Nevada High Temperature Seismic & Acceleration Sensor Systems
Bently Nevada 350300 Dynamic Pressure Sensor
Bently Nevada 3300 XL 25 mm Proximity Transducer System
Bently Nevada 3300 XL NSv Proximity Transducer System
9200, 74712 Seismoprobe Velocity Transducer System
Bently Nevada 31000, 32000 Proximity Probe Housings
Bently Nevada 330500 Velomitor Piezo-Velocity Sensor
Bently Nevada传感器和震动变送器
Bently Nevada本特利 3300 REBAM传感器
本特利Bently Nevada 3500系统监测器模块
Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE’s System 1® machinery management software. The TDI combines the capability of a 3500/20 Rack Interface Module with the data collection capability of a communication processor such as TDXnet. The TDI operates in the RIM slot of a 3500 rack in conjunction with the M series monitors (3500/40M, 3500/42M, etc.) to continuously collect steady state and transient waveform data and pass this data through an Ethernet link to the host software. Static data capture is standard with the TDI, however using an optional Channel Enabling Disk will allow the TDI to capture dynamic or transient data as well. The TDI features improvements in several areas over previous communication processors and incorporates the Communication Processor function within the 3500 rack. Although the TDI provides certain functions common to the entire rack it is not part of the critical monitoring path and has no effect on the proper, normal operation of the overall monitor system. Every 3500 rack requires one TDI or RIM, which always occupies Slot 1 (next to the power supplies). For Triple Modular Redundant (TMR) applications, the 3500 System requires a TMR version of the TDI. In addition to all the standard TDI functions, the TMR TDI also performs “monitor channel comparison”. The 3500 TMR configuration executes monitor voting using the setup specified in the monitor options. Using this method, the TMR TDI continually compares the outputs from three (3) redundant monitors. If the TDI detects that the information from one of those monitors is no longer equivalent (within a configured percent) to that of the other two monitors, it will flag the monitor as being in error and place an event in the System Event List.
A: Transient Data Interface Type 0 1 Standard (Use for standard monitoring applications) 0 2 TMR (Use only for applications that require a Triple Modular Redundant Configuration).
B: I/O Module Type 0 1 10Base-T/100Base-TX Ethernet I/O module 0 2 100Base-FX (Fiber Optic) Ethernet I/O module