5081 TWO-WIRE TRANSMITTERS FOR pH, ORP, CONDUCTIVITY, OXYGEN AND CHLORINE
品牌
其他厂商性质
深圳市所在地
深圳市大成机电技术有限公司
组合推荐相似产品
德国E+H通用型电导率测量变送器CLM223-CD0005
E+H余氯分析仪传感器CCS140
COS61-A1F0 E+H溶解氧分析仪传感器
德国E+H 溶解氧探头传感器电极COS61D-AAA1A3
E+H恩德斯豪斯PH数字电极CPS11D-7AA21
E+H恩德斯豪斯PH数字电极CPS11-2BA2ESA
E+H恩德斯豪斯PH数字电极CPS11D-7BA2G
E+H PH数字电极CPS11D-7BA21
E+H恩德斯豪斯浊度测量传感器 CUS51D
E+H恩德斯豪斯ENDRESS+HAUSER单通道变送器 CM42
E+H恩德斯豪斯pH/ORP面板变送器 CPM223
E+H恩德斯豪斯ENDRESS+HAUSER模拟式pH电极 CPF81
calibration data during power failures.
FEATURES AND APPLICATIONS The Model 5081 family of transmitters can be used to measure pH, ORP, conductivity (using either contacting or toroidal sensors), resistivity, oxygen (ppm and ppb level), free chlorine, total chlorine, and ozone in a variety of process liquids. The 5081 is compatible with most Rosemount Analytical sensors. See the Specification sections for details. The transmitter has a rugged, weatherproof, corrosion- resistant enclosure (NEMA 4X and IP65) of epoxy-painted aluminum. The enclosure also meets NEMA 7B explosion-proof standards. The transmitter has a two-line seven-segment display. The main measurement appears in 0.8-inch (20 mm) high numerals. The secondary measurement, temperature (and pH if free chlorine is being measured), appears in 0.3-inch (7 mm) high digits.
Two digital communication protocols are available: HART (model option -HT) and Foundation Fieldbus (model options -FF or -FI). Digital communications allows access to AMS (Asset Management Solutions). Use AMS to set up and configure the transmitter, read process variables, and troubleshoot problems from a personal computer or host anywhere in the plant. A handheld infrared remote controller or the HART and Foundation Fieldbus Model 375 communicator can also be used for programming and calibrating the transmitter. The remote controller works from as far away as six feet.
Model 5081-P pH/ORP Transmitter • CHANGING FROM pH TO ORP operation takes only seconds. • AUTOMATIC TWO-POINT BUFFER CALIBRATION reduces errors. • SOLUTION TEMPERATURE COMPENSATION converts measured pH to the pH at 25°C. • CONTINUOUS DIAGNOSTICS monitor sensor performance and warn the user of failure (FAULT) or approaching failure (WARNING).
Model 5081-T Toroidal Conductivity Transmitter • MEASURES CONDUCTIVITY, PERCENT CONCENTRATION, OR CUSTOM CURVE VARIABLE. • AUTOMATIC TC RECOGNITION simplifies start up. • AUTOMATIC/MANUAL TEMPERATURE COMPENSATION ensures accurate monitoring and control. • BUILT-IN CONCENTRATION CURVES FOR 0-12% NaOH, 0-15% HCl, 0-25% and 96-99.7% H2SO4. • PROGRAMMABLE REFERENCE TEMPERATURE enables temperature compensation to temperatures other than 25 degrees Celsius. • AUTOMATIC COMPENSATION FOR SENSOR CABLE RESISTANCE improves accuracy of high conductivity measurements.
Model 5081-C Contacting Conductivity Transmitter • MEASURES CONDUCTIVITY, RESISTIVITY, OR CUSTOM CURVE VARIABLE. • AUTOMATIC TC RECOGNITION simplifies start up. • AUTOMATIC/MANUAL TEMPERATURE COMPENSATION ensures accurate monitoring and control. • AUTOMATIC COMPENSATION FOR SENSOR CABLE RESISTANCE improves accuracy of high conductivity/ low resistivity measurements. • BUILT-IN TEMPERATURE COMPENSATION ALGORITHMS include straight slope, ultrapure water, cation conductivity, and no compensation.
Model 5081-A Amperometric Transmitter • MEASURES dissolved oxygen (ppm and ppb level), free chlorine, total chlorine, and ozone. • SECOND INPUT FOR A pH SENSOR ALLOWS AUTOMATIC pH CORRECTION for free chlorine measurement. No expensive, messy reagents needed. • AUTOMATIC BUFFER RECOGNITON FOR pH CALIBRATION.