Model 2062 Czerny-Turner Monochromator for High Resolution Spectroscopy

Model 2062 Czerny-Turner Monochromator for High Resolution Spectroscopy

参考价: 面议

具体成交价以合同协议为准
2023-03-08 08:36:52
73
产品属性
关闭
北京埃光科技有限公司

北京埃光科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

LongestFocalLengthCommercialInstrumentPatented"Snap-In"gratingsExtendedwavelengthrangesettingRuggedConstructionwithMultipleslitlocations

详细介绍

商品描述

Longest Focal Length Commercial Instrument
Patented "Snap-In" gratings
Extended wavelength range setting
Rugged Construction with Multiple slit locations


· Longest Focal Length Commercial Instrument

· Patented "Snap-In" gratings

· Extended wavelength range setting

· Rugged Construction with Multiple slit locations


The McPherson Model 2062 is the highest resolution diffraction spectrometer commercially available. It can be operated with Double Pass (DP) optics for an additional two fold improvement. This unique 2-meter focal length Czerny Turner can be equipped with large gratings (up to 220 mm wide). Grating rotation in excess of 70 degrees is allowed and double pass optics can be installed. These double the dispersion and resolution without influencing the f/no. or aperture ratio.


An example of a Model 2062 in use for highly precise spectral-line measurements of the Sun as a star can be found at Synoptic Optical Long-term Investigations of the Sun (SOLIS) web site. This is a facility for solar observations over a long time frame, funded by the NSF and designed and built by the NSO. The 2062, pictured in their gallery, has provided ten years of high resolution spectra.


Model 2062 PDF Data Sheet


Optical Design

McPherson Model 2062 2-meter focal length f/14.1 Monochromator

Focal Length

2-meters, Czerny Turner design Spectrometer with Patented "Snap-In" gratings

Aperture Ratio

14.1 (17.4 with smaller grating)

Wavelength Range

refer to grating of interest for range, in extended position increase top limit 20%

Wavelength Accuracy

+/-0.05 nm (with 1200 G/mm grating)

Wavelength Reproducibility

+/- 0.005 nm (with 1200 G/mm grating)

Grating Size

120 x 140-mm (or 110 x 110-mm) - Echelle gratings up to 220-mm wide

Slit Locations

Axial and lateral with optional extra entrance and exit port selection mirrors

Focal Plane

50-mm maximum width, multiply dispersion by the width of your detector for range

Performance with various diffraction gratings:

Grating (G/mm) (others available)

2400

1800

1200

600

300

150

75

20

Wavelength Range from 185-nm to

650nm

860nm

1.3um

2.6um

5.2um

10.4um

20.8um

78um

Resolution (nm) at 313.1-nm

0.003

0.004

0.005

0.010

0.020

0.040

0.080

0.300

Dispersion (nm/mm)

0.21

0.28

0.42

0.84

1.68

3.36

6.72

25.2

First Order Littrow Blaze (nm)

240nm

Holo

250nm

300nm

750nm

1.25um

2.0um

45um


300nm


300nm

500nm

1.0um

2.5um

3.0um












Holo


500nm

750nm

3.0um

4.0um

8.0um














750nm

1.0um

4.0um

6.0um

10.0um














1.0um

1.85um


8.0um

12.0um












上一篇:高精度光栅测长仪的使用维护指南 下一篇:如何进行高精度光栅测长机的校准?
热线电话 在线询价
提示

仪表网采购电话