This high-spec H2S detector uses a semiconductor sensor that overcomes most of the problems associated with this technology. The MultiTox DM-TT6 has higher reliability and lower maintenance. In other words: Increased safety and reduced cost.
The DM-TT6 is a solid-state metal oxide semiconductor (MOS) gas detector used mainly for the detection of hydrogen sulphide in arid locations having air present. The DM-TT6 can also be configured for other gases, such as refrigerants (e.g. R22).
The unit employs a robust sensing element that needs recalibration just once a year. In addition the device does not need a high gas concentration dose to reactive the active sensing material.
The intelligent, microprocessor driven unit is fully configurable using a wireless handheld terminal (TLU) giving true flexibility to the installer. Elements such as relay operation and alarm levels are all set via the TLU, hazardous area approved handheld unit.
The device offers a wide range of output options as standard and is suitable for use in SIL 2 applications. The unit may be interfaced directly with a wide range of panels, controllers and PLC’s etc.
The may be used in refineries, offshore driling and production platforms, processing and storage plants as well as chemical plants.
技术参数:
GENERAL | |
Type | Gas detector |
Product | Simtronics MultiTox, H2S (MOS) |
Product code | DM-TT6-31** |
Manufacturer | Simtronics |
GAS DETECTOR | |
Type | Solid state metal oxide semiconductor (MOS) |
Detected gas | Hydrogen Sulphide (H2S) |
Calibrated range | 50ppm, 100ppm |
PERFORMANCE | |
Accuracy | ±10% of calibrated range |
Repeatibility | ±2% |
Stability | ±2% (zero point) |
Response time | T50: <30 sec, T90: <120 sec |
Calibration interval | 12 months |
Sensor life | Better than 5 years |
ELECTRICAL | |
Power supply | 24V DC, range (18 - 32V DC) |
Power consumption | 65 mA normal |
Cable entry | 2x M20, one entry with Exd plug |
Junction box | “No-touch” field cabling”, detector replaceable without opening cable glands |
Connection | 0.3 mm2 (22 AWG) - 1.5 mm2 (16 AWG), 3 or 4 wires |
Analogue output signal | 0-20mA, source, max. load impedance 700Ω. |
Fault signalling | Diagnosis signalling in the 2.0 - 3.4mA range |
Relays | 2 individual configurable relays for alarm and fault |
Maintenance interface | Wireless (IR) handheld terminal for configuration, test and diagnosis |
ENVIRONMENT | |
Storage | -40°C to +70°C (-40°F to 158°F) |
Operation | -20°C to +60°C (-4°F to 140°F) |
Humidity | 95% RH (non-condensing) |
Ingress | IP66 |
RFI/EMI | Complies with EN50081-1, EN50081-2, EN50082-1 and EN50082-2. |
HOUSING | |
Ex Classification | Ex d II C T6 |
Material | Epoxy coated aluminium or Stainless steel (Specify variant) |
Weight | Aluminium: 1.8 Kg (4.0 lbs) Stainless steel: 6.5 Kg (14.3 lbs) |
Dimensions | 165H x 118D x 184W (mm), 6.50H x 4.65D x 7.25W (inches) |
APPROVALS | |
ATEX | Certificate DM LCIE 03 ATEX 6263 |
IECEx | Certificate DM IECEx LCI09.0018 |
ACCESSORIES | |
TLU600 | Infrared remote control unit |
AS008-200 | Sunshade |
AS005 | Calibration cup |
AS011-2-X | Sample flow housing |
AS019 | Splash guard |
Product Sheet MultiTox DM TT6453.56 KB
Operating Manual MultiTox Detector2.13 MB
Operating Manual Remote Controller TLU 600/6102.93 MB