The MultiFlame DM-TV6-T is a multi-spectrum infrared flame detector using three wavelengths. DM-TV6-T responds to hydrocarbon fires and is the right choice for operating in dirty environments or for the detection of smokey fires.
The DM-TV6-T is designed to respond to unwanted hydrocarbon fires, whilst maintaining a high degree of false alarm
immunity. The device offers a wide range of output options, as standard and is suitable for use in SIL 3 applications. The unit may be interfaced directly with a wide range of fire panels, controllers and PLC's etc.
The unit is fully configurable using a wireless handheLd terminaL (TLU) giving true flexibility to the installer. Time delays, sensitivity and output configuration are all set up via the TLU, a hazardous area approved handheld unit.
Wireless testing of the optical and output circuits is also possible using the TLU too
技术参数:
GENERAL | |
Type | Flame detector |
Product | Simtronics MultiFlame 3xIR |
Product code | Standard range: DM-TV6-XTA0-*; Long range: DM-TV6-XTB0-* |
Manufacturer | Simtronics |
FLAME DETECTOR | |
Type / Principle | Optical flame detection |
Technology | Multispectrum Infrared flame detector |
Fire Types | Hydrocarbon fires |
Modularity | Replaceable sensor cartridge |
PERFORMANCE | |
Cone of vision | 110 deg horizontal, 95 deg vertical |
Response time | 2 sec. Additional adjustable delay 3 - 20 sec |
Detection range: | |
- n-heptane (1 sq ft fire) | Standard: 40m (130ft). Long range: 80m (260ft) |
- Gasoline (1 sq ft fire) | Standard: 33 m (110 ft). Long range: 65 m (210 ft) |
ELECTRICAL | |
Power supply | 24V DC, range (18 - 32V DC) |
Power consumption | 70 mA normal; 155 mA during self test |
Cable entry | 2x M20, one entry with Exd plug |
Junction box | “No-touch” field cabling”, detector replaceable without opening cable glands |
Connection | 0.3 mm2 (22 AWG) - 1.5 mm2 (16 AWG), 3 or 4 wires |
Analogue output signal | 0-20mA, source, max. load impedance 700Ω. |
Fault signalling | Diagnosis signalling in the 2.0 - 3.4mA range |
Relays | 2 configurable relays for fire and fault |
Maintenance interface | Wireless (IR) handheld terminal for configuration, test and diagnosis |
ENVIRONMENT | |
Storage | -40°C to +70°C (-40°F to 158°F) |
Operation | -20°C to +60°C (-4°F to 140°F) |
Humidity | 95% RH (non-condensing) |
Ingress | IP66 |
RFI/EMI | Complies with EN50081-1, EN50081-2, EN50082-1 and EN50082-2. |
HOUSING | |
EX Classification | Ex d II C T6 |
Material | Epoxy coated aluminium or Stainless steel (Specify variant) |
Weight | Aluminium: 3.3 Kg (7.3 lbs), Stainless steel: 7.4 kg (16.3 lbs) |
Dimensions | 223L x 118D x 184H (mm), 8.78L x 4.65D x 7.25H (inches) |
APPROVALS | |
ATEX | Certificate DM LCIE 03 ATEX 6263 |
IECEx | Certificate DM IECEx LCI09.0018 |
SIL | Certificate Suitable for use in SIL3 systems |
ACCESSORIES | |
TLU600 | Infrared remote control unit |
LT15 | Test lamp (EX flame simulation torch) |
AS008-350 | Sunshade |
AS030-A/X | Multi-position angle wall mounting |
AS035-A/X | Pivot ball mounting bracket |
AS040 | Sun visor (long, open) |
AS041 | Sun visor (long, narrow) |
Product Sheet 377.89 KB
Operating Manual1.58 MB
Operating Manual (Italian)1.04 MB
Operating Manual (Portuguese)2.87 MB
证书:
ATEX Certificate2.06 MB
Certificate of Conformity CE363.96 KB
HART 7 Certification47.4 KB
IECEx Certification3.6 MB
SIL Certification DM-TV6-T541.91 KB
应用:
• Refineries
• Drilling and Production PLatforms
• FueL Loading Facilities
• Compressor Stations
• LNG/LPG Processing and Storage
• Gas Turbines
• ChemicaL PLants
• Aircraft Hangars
• Sports Stadia / Atria