Continuous analysis of flue gas for any combination and range of O2, CO, CO2, SO2, NOx (NO or NO + NO2) or combustibles from combustion processes.
larger image
larger image
Results per Page :
Results 1 - 18 of 18
1
Item #
Gases Measured
Method of Detection
Ranges Available
Resolution
7200-1
Oxygen (O2)
Electrochemical sensor, paramagnetic sensor or zirconia sensor (depending on desired accuracy and sample composition)
0-5 to 0-25% O2
0.1% on % ranges, 1 PPM on PPM ranges
7200-2
Carbon Monoxide (CO)
PPM CO by electrochemical sensor, % CO by NDIR infrared detector
0-100, 0-250, 0-500, 0-2000 by E/C, 0-10,000 PPM CO by infrared detector
0.1% on %, 1 PPM on PPM
7200-3
Carbon Dioxide (CO2)
Infrared detector
0-20% CO2
0.1% on %, 1 PPM on PPM
7200-4
Oxides of nitrogen (NOx (as NO))
PPM NO by electrochemical sensor
0-100 to 0-5000 PPM NOx (as NO)
1 PPM
7200-5
Combustibles (LEL, CH4, H2, CO, other)
Catalytic sensor (incl. air make up)
0-2, 0-5, 0-10% Combustibles
0.1%
7200-7
SO2 (Sulphur Dioxide)
PPM SO2 by electrochemical sensor, % SO2 by infrared detector
0-100 PPM to 0-5% SO2
0.1% on %, 1 PPM on PPM
7200-1-3
Oxygen (O2) and CO2
O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor (depending on desired accuracy and sample composition), CO2 by NDIR infrared detector
0-5 to 0-25% O2, 0-20% CO2
0.1%
7200-1-4
Oxygen (O2) and Oxides of nitrogen (NOx (as NO))
O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor (depending on desired accuracy and sample composition), NOx (as NO) by electrochemical sensor
0-5 to 0-25% O2, 0-20% CO2, 0-100 to 0-5000 PPM NOx (as NO)
% O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor, PPM CO by electrochemical sensor or NDIR infrared detector, % CO by infrared detector, % CO2 by NDIR infrared detector
0-5 to 0-25% O2, 0-100, 0-250, 0-500, 0-2000, 0-10,000 PPM CO, 0-20% CO2
% O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor, PPM CO by electrochemical sensor or infrared detector, % CO by infrared detector, NOx (as NO) by electrochemical sensor
0-5 to 0-25% O2, 0-100 PPM to 0-99% CO, 0-100 to 0-5000 PPM NOx (as NO)
PPM CO by electrochemical sensor or NDIR infrared detector, % CO by infrared detector, % CO2 by NDIR infrared detector, % CO2 by NDIR infrared detector
0-5 to 0-25% O2, 0-100, 0-250, 0-500, 0-2000, 0-10,000 PPM CO, 0-20% CO2
O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor (depending on desired accuracy and sample composition), PPM CO by electrochemical sensor, % CO by NDIR infrared detector
0-5 to 0-25% O2, 0-100 PPM to 0-99% CO
0.1% on % ranges, 1 PPM on PPM range
7200-3-4
Carbon Dioxide (CO2), Oxides of Nitrogen (NOx (as NO))
% CO2 by NDIR infrared detector, PPM NOx (as NO) by electrochemical sensor
% O2 by electrochemical, paramagnetic or zirconia sensor, PPM CO by electrochemical sensor or infrared detector, % CO by infrared detector, % CO2 by infrared detector, PPM Comb by electrochemical sensor, % Comb by infrared detector
0-5 to 0-25% O2, 0-100, 0-250, 0-500, 0-2000, 0-10,000 PPM CO, 0-20% CO2, 0-2% to 0-10% Combustibles
% O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor, PPM CO by electrochemical sensor or NDIR infrared detector, % CO by infrared detector, PPM NO or NO2 by electrochemical sensor
0-5 to 0-25% O2, 0-100 PPM to 0-99% CO, 0-100 to 0-5000 PPM NO, 0-100 PPM to 0-800 PPM NO2
% O2 by electrochemical, paramagnetic or zirconia sensor, PPM CO by electrochemical sensor or infrared detector, % CO and CO 2 by infrared detector, NOx (as NO) and SO2 by electrochemical sensor
0-5 to 0-25% O2, 0-100 PPM to 0-99% CO, 0-20% CO2, 0-100 to 0-5000 PPM NOx (as NO), 0-100 PPM to 0-5% SO2