7900P系列工业过程便携式气体分析仪

7900P系列工业过程便携式气体分析仪7900P系列工业过程便携式气体分析仪

参考价: 面议

具体成交价以合同协议为准
2023-03-09 08:13:02
115
产品属性
关闭
上海美盛自动化设备有限公司

上海美盛自动化设备有限公司

免费会员
收藏

组合推荐相似产品

产品简介

7900P系列工业过程便携式气体分析仪为监测热处理任何一氧化碳(CO),二氧化碳(CO2),甲烷(CH4),氢气(H2),氧气(O2)和气体的露点相结合的氛围。也可用于其他工业生产过程,包括氢气。

详细介绍

7900P系列工业过程便携式气体分析仪
为监测热处理任何一氧化碳(CO),二氧化碳(CO2),甲烷(CH4),氢气(H2),氧气(O2)和气体的露点相结合的氛围。也可用于其他工业生产过程,包括氢气。

Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes - 7900P Series

Check up to five results to perform an action.

7900P-Series

larger image
For monitoring heat treating atmosphere gases in any combination of Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Hydrogen (H2), Oxygen (O2) and dew point. Also available for other industrial processes that include hydrogen.

Search Items


Request QuoteCompare Items Results per Page :
Results 1 - 22 of 22 1

Item #

Enclosure and Mounting Details

Resolution

Output Options

Analyzer Type

Model 7900P-1A Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Single Gas Analyzers, Carbon Monoxide only 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-1AS Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Single Gas Analyzers, Combustibles = CO x 2 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-1B Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Single Gas Analyzers, Carbon Dioxide only 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-1C Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Single Gas Analyzers, Methane only 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-1D Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Single Gas Analyzers, Hydrogen only 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-2A Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Double Gas Analyzers, Carbon Monoxide & Carbon Dioxide 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-2B Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Double Gas Analyzers, Carbon Monoxide & Hydrogen 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-2C Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Double Gas Analyzers, Carbon Monoxide & Oxygen 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-2D Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Double Gas Analyzers, Oxygen & Methane 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-2E Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Double Gas Analyzers, Hydrogen & Carbon Dioxide 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-2G Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, Double Gas Analyzers, Oxygen & Hydrogen 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-3A Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 3 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, & Methane 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-3A-CP Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 3 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, Methane, & Carbon Potential 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-3B Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 3 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, & Hydrogen 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-3C Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 3 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, & Oxygen 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-3D Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 3 Gas Analyzers, Oxygen, Carbon Monoxide, & Methane 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-3E Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 3 Gas Analyzers, Oxygen, Carbon Monoxide, & Hydrogen 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-4A Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 4 Gas Analyzers, Oxygen, Carbon Monoxide, Carbon Dioxide, & Methane 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-4B Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 4 Gas Analyzers, Oxygen, Carbon Monoxide, Carbon Dioxide, & Hydrogen 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-4C Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 4 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, Methane, & Hydrogen 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-4D Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 4 Gas Analyzers, Oxygen, Carbon Monoxide, Methane, & Hydrogen 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer
Model 7900P-4E Portable Gas Analyzer for Heat Treating and Other Hydrogen-Based Industrial Processes, 4 Gas Analyzers, Oxygen, Carbon Dioxide, Methane, & Hydrogen 0.1% on % versions, 10 PPM on PPM versions 4-20 mA for each gas measured. 0-1 VDC or serial output also available Heat Treating Analyzer