SensAlert & SensAlert Plus Sensor Data TableSensidyne插件传感器是在气体探测传感器可用于多种应用在许多行业广泛。*的智能传感器的Sensidyne公司制造,并从选定的供应商是检测有毒和可燃气体以及缺氧或浓缩可用。智能Sensidyne传感器含有非挥发性气体的名称或类型,跨度,内存计量单位,报警级别,*新的零点和量程校准数据,补偿表.

详细介绍

SensAlert & SensAlert Plus Sensor Data Table
Sensidyne插件传感器是在气体探测传感器可用于多种应用在许多行业广泛。*的智能传感器的Sensidyne公司制造,并从选定的供应商是检测有毒和可燃气体以及缺氧或浓缩可用。智能Sensidyne传感器含有非挥发性气体的名称或类型,跨度,内存计量单位,报警级别,*新的零点和量程校准数据,补偿表.

Gas Detection Sensors
Sensidyne plug-in gas detection sensors are available for a wide array of applications in many industries. Advanced intelligent sensors manufactured by Sensidyne, and from selected suppliers are available for detecting toxic and combustible gases as well as oxygen deficiency or enrichment.
Intelligent Sensidyne sensors contain non-volatile memory for gas name or type, span, measuring units, alarm levels, the latest zero and span calibration data, compensation tables, remaining sensor life, factory codes and history, time and date stamp, as applicable.
SensAlert & SensAlert Plus Sensors
Flammable Gas Reference Chart
Toxic Gas Reference Chart


SensAlert & SensAlert Plus Sensor Data Table
SensAlert P/N SensAlert PLUS P/N TARGET GAS OR VAPOR GAS DATA1, 2 SENSOR ToD Response Time ENVIRONMENTAL9
Formula Density TLV-TWA IDLH Span4-Units Type1, 3 Cell8 T506 T906 Temp. F Humidity
011243-D-3X 823-0201-22 FM Ammonia NH3 0.6 25 ppm 300 ppm 50 ppm EC-LI, D3 n/a 11 70 -4° to 122o 15-90% RH
011243-D-1 823-0201-21 FM Ammonia NH3 0.6 25 ppm 300 ppm 100 ppm EC-LI, D n/a 11 70 -4° to 122o 15-90% RH
011243-D-2 823-0201-41 Ammonia NH3 0.6 25 ppm 300 ppm 300 ppm EC-LI, D n/a 15 90 -4° to 122o 10-90% RH
011343-D-1 823-0201-42 Ammonia NH3 0.6 25 ppm 300 ppm 500 ppm EC-LI, D n/a 20 90 -4° to 122o 10-90% RH
n/a 823-0249-51 Acetylene IR C2H2 0.9 Asphyxiate - - 50% LEL Infrared n/a 10 30 -30° to131° 5-95% RH
121042-D-1 Pending Arsine AsH3 2.7 0.05 ppm 3 ppm 1.00 ppm EC, ND3 n/a 50 90 -4° to 122o 5-95% RH
Use Chlorine Use Chlorine Bromine Br2 5.5 3.0 ppm 3 ppm 10 ppm EC, D n/a - - - - -4° to 122o 5-95% RH
n/a 823-0205-51 Carbon Dioxide IR CO2 1.5 0.50% 3.00% 5.00% Vol. Infrared n/a 65 105 -4° to 131o 0-95% RH
195272-D-1 823-0219-23 FM Carbon Monoxide CO 0.94 25 ppm 1,200 ppm 100 ppm EC, ND n/a 10 30 -4° to 122o 15-90% RH
195272-D-4 Pending Carbon Monoxide CO 0.94 25 ppm 1,200 ppm 300 ppm EC, ND n/a 10 30 -4° to 122o 15-90% RH
195272-D-2 823-0219-22 FM Carbon Monoxide CO 0.94 25 ppm 1,200 ppm 500 ppm EC, ND n/a 10 30 -4° to 122o 15-90% RH
195272-D-3X Pending Carbon Monoxide CO 0.94 25 ppm 1,200 ppm 1000 ppm EC, ND n/a 10 30 -4° to 122o 5-95% RH
198262-D-1 823-0219-41 Carbon Monoxide CO 0.94 25 ppm 1,200 ppm 100 ppm EC-LI, ND n/a 10 30 -4° to 122o 15-90% RH
198262-D-2 823-0219-42 Carbon Monoxide CO 0.94 25 ppm 1,200 ppm 500 ppm EC-LI, ND n/a 10 30 -4° to 122o 15-90% RH
025142-D-2 823-0202-22 FM Chlorine Cl2 2.5 0.5 ppm 10 ppm 5.00 ppm EC, ND C 10 40 -4° to 122o 15-90% RH
025142-D-1 823-0202-21 FM Chlorine Cl2 2.5 0.5 ppm 10 ppm 10.0 ppm EC, ND C 10 40 -4° to 122o 15-90% RH
n/a 823-0202-23 Chlorine Cl2 2.5 0.5 ppm 10 ppm 20.0 ppm EC, ND C 10 30 -4° to 122o 15-95% RH
021232-D-3 Pending Chlorine Cl2 2.5 0.5 ppm 10 ppm 100 ppm EC, ND n/a 18 60 -4° to 122o 5-95% RH
021201-D-1 n/a Chlorine Cl2 2.5 0.5 ppm 10 ppm 10.0 ppm Refillable EC n/a 60 120 23° to 113o 5-95% RH
391132-D-1 823-0239-21 Chlorine Dioxide ClO2 2.3 0.1 ppm 5 ppm 1.00 ppm EC, ND C 20 120 -4° to 122o 15-90% RH
111250-D-1 823-0211-31 FM Combustibles, General - - - - Asphixiate - - 99% LEL Catalytic n/a T-60: <12 sec -40° to167° 5-95% RH
111253-D-1 823-0211-32 Comb. H2, ETO, Acetylene - - - - Asphixiate - - 99% LEL Catalytic n/a T-60: <5 sec -4° to122° 5-95% RH
101236-D-1 823-0210-41 Hydrogen Specific LEL H2 0.07 Asphixiate - - 99% LEL EC, ND n/a 20 70 -4° to 122o 15-90% RH
n/a 823-0211-51 FM Combustibles IR Hydrocarbons Asphixiate - - 99% LEL Infrared n/a T-60: <12 sec -13° to 167o 0-99% RH
491255-D-1 823-0249-51 Combustibles IR Acetylene C2H2 0.9 2,500 ppm - - 50% LEL Infrared n/a 10 30 -4° to 122o 5-95% RH
291042-D-1 Pending Diborane B2H6 2.9 0.1 ppm 15 ppm 1.00 ppm EC, ND n/a 45 100 -4° to 122o 5-95% RH
c/f Pending Dichlorosilane SiH2Cl2 1.3 5 ppm - - 10.0 ppm EC, ND n/a 30 90 -4° to 122o 5-95% RH
452132-D-1 823-0245-21 Ethylene Oxide (ETO) C2H4O 1.5 1 ppm 800 ppm 10.0 ppm EC, ND n/a 15 60 -4° to 104o 15-95% RH
151142-D-1X 823-0215-21 Fluorine F2 1.3 0.1 ppm 25 ppm 10.0 ppm EC, ND n/a 10 30 -4° to 122o 5-95% RH
151142-D-2X 823-0215-22 Fluorine F2 1.3 0.1 ppm 25 ppm 25.0 ppm EC, ND n/a 10 30 -4° to 122o 5-95% RH
302042-D-1 Pending Germane GeH4 2.7 0.2 ppm - - 2.00 ppm EC, ND n/a 10 30 -4° to 122o 5-95% RH
481042-D-1X Pending Hydrazine N2H4 1.1 0.01 ppm 50 ppm 1.00 ppm EC, ND n/a 30 120 -4° to 122o 5-95% RH
101332-D-1 823-0210-21 FM Hydrogen Specific PPM H2 0.07 Asphixiate - - 1000 ppm EC, ND n/a 20 70 -4° to 122o 15-90% RH
101236-D-1 823-0210-41 Hydrogen Specific LEL H2 0.07 Asphixiate - - 99% LEL EC, ND n/a 40 120 -4° to 122o 15-90% RH
Use HCl Use HCl Hydrogen Bromide HBr 2.8 3 ppm 30 ppm 10.0 ppm EC, ND n/a 45 120 -4° to 122o 5-95% RH
083142-D-3X 823-0208-21 FM Hydrogen Chloride HCl 1.3 2 ppm 50 ppm 10.0 ppm EC, ND S 15 30 -4° to 122o 15-90% RH
083142-D-1 823-0208-22 FM Hydrogen Chloride HCl 1.3 2 ppm 50 ppm 20.0 ppm EC, ND S 15 30 -4° to 122o 15-90% RH
081201-D-1 n/a Hydrogen Chloride HCl 2.3 2 ppm 50 ppm 10.0 ppm Refillable EC n/a 40 180 23° to 104o 5-95% RH
081232-D-2 Pending Hydrogen Chloride HCl 2.3 2 ppm 50 ppm 100 ppm EC, ND n/a 36 120 -4° to 122o 5-95% RH
033142-D-1 823-0203-21 Hydrogen Cyanide HCN 0.9 4.7 ppm 50 ppm 20.0 ppm EC, D3 n/a 10 30 -4° to 122o 15-95% RH
031232-D-2X Pending Hydrogen Cyanide HCN 0.9 4.7 ppm 50 ppm 100 ppm EC, D n/a 45 150 -4° to 122o 5-95% RH
071142-D-1 823-0207-21 FM Hydrogen Fluoride HF 0.7 0.5 ppm 30 ppm 10.0 ppm EC, D C 15 45 -4° to 122o 15-90% RH
071142-D-2X 823-0207-22 FM Hydrogen Fluoride HF 0.7 0.5 ppm 30 ppm 20.0 ppm EC, D C 15 45 -4° to 122o 15-90% RH
071201-D-1 n/a Hydrogen Fluoride HF 0.7 0.5 ppm 30 ppm 10.0 ppm Refillable EC n/a 60 300 23° to 104o 5-95% RH
062272-D-1 823-0206-22 FM Hydrogen Sulfide H2S 1.2 10 ppm 100 ppm 50 ppm EC, ND S 10 30 -40o to 122° 15-90% RH
062272-D-2 823-0206-21 FM Hydrogen Sulfide H2S 1.2 10 ppm 100 ppm 100 ppm EC, ND S 10 30 -40o to 122° 15-90% RH
421232-D-1 823-0242-21 Nitric Oxide NO 1 25 ppm 100 ppm 100 ppm EC, ND n/a 5 15 -4° to 122o 5-95% RH
211232-D-1 823-0221-21 Nitrogen Dioxide NO2 1.6 3 ppm 20 ppm 10.0 ppm EC, ND n/a 15 40 -4° to 122o 15-90% RH
403162-D-1 823-0240-41 FM Oxygen O2 1.13 <19.5% <18% 25.0%Vol EC, D n/a 4 10 -4° to 122o 15-90% RH
403162-D-2X n/a Oxygen, Process O2 1.13 - - - - 10.0%Vol EC, D n/a 4 10 -4° to 122o 5-95% RH
403162-D-3X n/a Oxygen, Process O2 1.13 - - - - 25.0%Vol EC, D n/a 4 10 -4° to 122o 5-95% RH
403172-D-3 n/a Oxygen, Membrane O2 1.13 <19.5% <18% 25.0%Vol EC, D n/a - - <10 50° to 104o 5-95% RH
432032-D-1 Pending Ozone O3 1.6 0.1 ppm 5 ppm 2.00 ppm EC, ND n/a 45 150 -4° to 122o 5-95% RH
471042-D-1X 823-0247-21 Phosgene COCl2 3.4 0.1 ppm 2 ppm 1.00 ppm EC, ND n/a 60 120 -4° to 122o 15-90% RH
131042-D-1 Pending Phosphine PH3 1.2 0.3 ppm 50 ppm 1.00 ppm EC, ND n/a 10 30 -4° to 122o 5-95% RH
145142-D-1 Pending Silane SiH4 1.3 5 ppm - - 10.0 ppm EC, ND n/a 30 90 -4° to 122o 5-95% RH
462273-D-1X Pending Styrene C8H8 3.6 20 ppm 700 ppm 200 ppm EC, ND n/a 25 75 -4° to 122o 5-95% RH
n/a 823-0218-22 FM Sulfur Dioxide, H2S Filtered SO2 2.3 2 ppm 100 ppm 10.0 ppm EC, ND n/a 10 15 -4° to 122o 15-90% RH
182132-D-3X n/a Sulfur Dioxide SO2 2.3 2 ppm 100 ppm 10.0 ppm EC, ND n/a 10 15 -4° to 122o 5-95% RH
182132-D-1 n/a Sulfur Dioxide SO2 2.3 2 ppm 100 ppm 20.0 ppm EC, ND n/a 5 15 -4° to 122o 5-95% RH
181233-D-1 823-0218-21 FM Sulfur Dioxide, H2S Filtered SO2 2.3 2 ppm 100 ppm 20.0 ppm EC, ND n/a 10 15 -4° to 122o 15-90% RH
181233-D-2 Pending Sulfur Dioxide, H2S Filtered SO2 2.3 2 ppm 100 ppm 100 ppm EC, ND n/a 5 20 -4° to 122o 15-90% RH
181201-D-1X n/a Sulfur Dioxide SO2 2.3 2 ppm 100 ppm 10.0 ppm Refillable EC n/a 40 240 23° to 104o 15-90% RH
SensAlert P/N SensAlert PLUS P/N TARGET GAS OR VAPOR Formula Density TLV-TWA IDLH Span4-Units Type1, 3 Cell8 T506 T906 Temp. F Humidity
GAS DATA1, 2 SENSOR ToD Response Time ENVIRONMENTAL9
1 Refillable means membrane and electrolyte are renewable, <: Less than or equal to, >: Greater than or equal to, n/a: not available.
2 Gas Data are from ACGIH (TLV-TWA) and NIOSH (IDLH) but may be noted as Ceiling or STEL. The user is responsible for verifying table data.
3 D: Sensor life is directly proportional to target gas exposure. ND: Sensor is not depleted by exposure to target gas and life is expected to be more than 2 years.
4 Lower Detection Limit is 3% of Span plus one digit (SensAlert) and 3% of span (PLUS). Number of zeros indicates sensor and display resolution.
7 LCD is the SensAlert gas type or name displayed. PLUS spells out the gas name or type.
8 ToD is the Test-on-Demand cell option and type designation for SensAlert PLUS only.
9 PLUS Temperature / Humidity specs given. Short term (hours) temperature / humidity excursions acceptable.

Sensor Technologies
Electrochemical Sensors
Electrochemical sensors are primarily used to detect toxic gases and oxygen. Toxic gases are detected in parts per million (PPM) while oxygen is measured in percent by volume (%Vol). Electrochemical sensors contain electrodes immersed in electrolyte inside a housing with a porous hydrophobic membrane. When the gas diffuses through the membrane into the electrolyte it produces a small but repeatable electrical current proportional to the gas concentration.
Catalytic Bead Sensors
Catalytic bead combustible sensors have been used since the 1930s. They consist of tiny heated wires embedded inside reference and sensing beads or pellistors. The sensing bead is coated with a catalyst so that combustible gases are oxidized if present. The heated beads operate in a bridge circuit that can produce a signal proportional to the concentration of combustible gas. Catalytic sensors require at least 10% by volume of Oxygen to operate properly and can be poisoned or inhibited by certain chemicals.
Infrared Sensors
Infrared sensors, or more specifically non-dispersive Infrared (NDIR) sensors, measure combustible gases and vapors in percent by volume (%Vol) ranges expressed as percent LEL (Lower Explosive Limit). NDIR sensors operate on the principle that hydrocarbon gases absorb specific wavelengths of infrared light. They are comprised of an infrared light source, reference and measurement detectors. The detector outputs are compared to indicate the presence of hazardous levels of gas. NDIR sensors do not require Oxygen to operate, always fail safe and cannot be poisoned.