Large Capacity Pilot (LCP) Operated Safety Valve提供一个符合成本效益的可靠的超压保护包。安德森格林伍德的LCP的系列先导式安全阀的设计提供了可靠的超压保护你所期望具有成本效益的方案。紧凑的大会借给自己提供更大的能力,从而优化整个泄压阀的安装。
详细介绍
Large Capacity Pilot (LCP) Operated Safety Valve 提供一个符合成本效益的可靠的超压保护包。安德森格林伍德的LCP的系列先导式安全阀的设计提供了可靠的超压保护你所期望具有成本效益的方案。紧凑的大会借给自己提供更大的能力,从而优化整个泄压阀的安装。
Large Capacity Pilot (LCP) Operated Safety Valve
Description
Specifications
Documentation
Provides reliable overpressure protection in a cost effective package.
Anderson Greenwood’s LCP Series pilot operated safety valve is designed to provide the reliable overpressure protection you have come to expect in a cost effective package. The compact assembly lends itself to supplying larger capacities that optimize the entire pressure relief valve installation.
The LCP Series valve has the capability to be used on almost all gases or vapors. The valve is available with inlet sizes of 1" to 3" [25 to 75 mm], set pressures from 25 to 2220 psig [1.72 to 153 barg], and continuous temperatures from -20°F to 400°F [-29°C to 204°C].
The scope of the LCP Series design is fixed upon these common sizes and set pressures, and comes equipped with typically required accessories as a standard. In fact, the only available option for the LCP Series valve is a trim for sour sulfide laden gases. This latest edition to our poprv line provides dependable safety in a low cost configuration.
Features & Benefits:
Rigid Pilot Mounting: No tubing anywhere on the valve provides ultimate protection against vibration and careless handling.
Balanced Design: Proper valve operation and lift are unaffected by back pressure. Costly and fragile metal bellows are not required.
Integral Back Flow Prevention: High superimposed back pressure or inlet vacuum will not open valve. Added protection and safety at no added cost.
Non-Flowing Pilot: Minimizes entrance of dirt or hydrates in the pilot to provide repeatable performance during multiple relieving cycles.
ASME Section VIII Code Stamp: Certified third party capacities for gas service.
Viton® Soft Seats and Seals: Reduces emissions and product loss while minimizing maintenance costs. No metal seat lapping is required.
Full Bore Orifices: Reduces upfront valve and associated piping costs.
Integral Field Test Connection: Standard feature that provides a safe and accurate way to do in-place performance tests.
NACE MR0175 Trim (2002 Edition): Optional trim materials available to meet sour gas requirement.
Specifications Sizes: 1" x 2" to 3" x 4" Orifices: 0.785 to 7.069 in2 [5.065 to 45.6 cm2] Inlet Ratings: ANSI Class 150 to 900 Temperature Range: -20 to +400°F [-29 to +205°C] Set Pressure Range: 25 to 2200 psig [1.72 to 151.72 barg]