DARK SPOT™ fixed sample analysis. Direct photo-detection of hydrocarbon condensate at hydrocarbon dew-point temperature
Sensor Cooling
Automatic via 3-stage Peltier effect electronic cooler
Maximum Range
±-34°C HCDP from 21°C ambient @ 27 barg (range depends on sensor temperature)
Accuracy
±0.5°C hydrocarbon dew point
Sample Gas Flow Rate
0.03m³/hr (0.5 Nl/min)
WATER DEW POINT MEASUREMENT (OPTIONAL)
Accuracy
±1°C from -59 to +20°C dew point ±2°C from -100 to -60°C dew point
Sample Gas Flow Rate
1 to 5 Nl/min
PRESSURE MEASUREMENT
Type
HCdp-Type PDCR 1050-3465: 0 to 100 barg Wdp-Type PDCR 1050-3574: 0 to 210 barg
Accuracy
±0.25% FS
HYDROCARBON DEW POINT ANALYZER
Sample Gas Supply
Natural gas up to 100 barg, pressure regulated in sampling system
Enclosure
EExd cast enclosure with removable glass window viewing port. Internally heated for condensation protection
Sample Gas Connections
¼" NPT female ports for both hydrocarbon and water dew-point channels
Operating Environment
Indoors/Outdoors -20 to 60°C. Max 95% RH
Power Supply
90-264 VAC 50/60 Hz, 200 W Main Unit; 300 W c/w indoor sampling system; 400 W c/w outdoor sampling system
Weight
Main Unit 22.5kg c/w Sampling System (indoor) 42kg (approx) c/w Sampling system (outdoor) 57kg (approx)
Integrated Display
Touch screen with vacuum fluorescent display
Outputs and Alarms
Modbus RTU, RS-485 @ 9600 baud rate Two 4-20 mA linear (non-isolated) outputs, user configurable for any combination of dew-point or pressure parameters Hydrocarbon and water dew-point alarms via software register. Integrated low flow alarms for each sample flow
OPTIONS AND ACCESSORIES:
Remote Interface Integrated safe-area control unit for Condumax II, providing display of all variables, charting and logging functions, parameter control and remote diagnostic facilities.
19" Sub-Rack unit with 6.5" colour LCD display and mouse control.
Remote two channel digital display for safe area use, providing indication of selected variables (any two from hydrocarbon dew point, water dew point or system pressures) on a bright, twin 3.5 digit LED display with analogue output re-transmission and dual alarms.
Plant control Integration ActiveX components to be used by software programmers for integration of modbus protocol into a general plant software system.