品牌
经销商厂商性质
上海市所在地
接头 | LUMBERG | VAD1A-1-3-M12-5 | |||||
电接点压力表 | LABOM | BE4330-C2058-M4410-H4-V3 0...10bar | |||||
安全门锁线 | EUCHNER | C-M12F08-08x025PV20.0-MA-100179 | |||||
模块 | BECKHOFF | CX1100-0002 | |||||
备件 | KEYSTONE | S8660U02 REV B | |||||
备件 | PHOENIX | HC-A 3-ESTS | |||||
备件 | PHOENIX | HC-B 06-I-PT-F | |||||
备件 | PHOENIX | HC-B 06-I-PT-M | |||||
备件 | PHOENIX | HC-B 10-I-PT-F | |||||
备件 | PHOENIX | HC-B 10-I-PT-M | |||||
备件 | PHOENIX | HC-B 10-TFQ-N-O1STM25G | |||||
备件 | PHOENIX | HC-B 16-I-PT-F32 | |||||
备件 | PHOENIX | HC-B 16-I-PT-F32 | |||||
备件 | PHOENIX | HC-B 16-I-PT-M32 | |||||
备件 | PHOENIX | HC-B 16-I-PT-M32 | |||||
备件 | PHOENIX | HC-B 16-TFQ-H-O1M32G | |||||
备件 | PHOENIX | HC-B 16-TFQ-N-O1M25S | |||||
备件 | PHOENIX | HC-B 16-TFQ-N-O1STM32G | |||||
备件 | PHOENIX | HC-B 24-I-PT-F | |||||
备件 | PHOENIX | HC-B 24-I-PT-M | |||||
备件 | PHOENIX | HC-B 24-TFQ-N-O1STM32G | |||||
备件 | PHOENIX | HC-B 32-AMQ | |||||
备件 | PHOENIX | HC-B 32-TFQ-80/O1STM40G | |||||
电源 | COMPETENT | 149002-31001 | |||||
编码器 | KUBLER | 8.5823.1831.1024 | |||||
转速探头 | DYNALCO | DYNALCOPARTNO.M334 | |||||
变压器 | HABERMANN | HT1268 1012861 | |||||
备件 | HOHNER | FMA-A/6G05M960BM | |||||
电源 | GEBRUGER FREI | 149002-31001 P/N:4105800 | |||||
备件 | RITTAL | sk 3373100 | |||||
备件 | LEROY SOMER | MB2301 B00C 791627901/002 | |||||
备件 | PHOENIX | HC-B 5-EBUC | |||||
备件 | PHOENIX | HC-B 5-ESTC | |||||
备件 | PHOENIX | HC-B 6-SML-52/O1M25 | |||||
备件 | PHOENIX | HC-B 6-TFL-N-O1M25S | |||||
备件 | PHOENIX | HC-B 6-TFL-N-O1STM25G | |||||
滚边轴 | FFT EDAG | RF-08-40-01 | |||||
限位 STOP | FFT EDAG | VP_00006 | |||||
配件 | TAKENAKA | HMD热金属探测器风管303NC | |||||
插头 | MENNEKES | NO:5792C | |||||
注油过滤器和通气滤清 | REXROTH | TLF3-4-50 P10 R900020753 | |||||
驱动组件 | WANDRES | 9104331 | |||||
泵 | WANDRES | 2313662 | |||||
电磁阀 | WANDRES | 4152765 | |||||
阀 | WANDRES | 2313513 | |||||
压力开关 | WANDRES | 9104145 | |||||
压力控制装置 | WANDRES | 2313506 | |||||
过滤器 | WANDRES | 2313467 | |||||
柔性缓冲剑刷 | WANDRES | 4145932 | |||||
法兰 | WANDRES | 4130904 | |||||
驱动轮 | WANDRES | 4130861 | |||||
螺母 | WANDRES | 4148255 | |||||
膜片 | WANDRES | 4135327 | |||||
机架 | WANDRES | 4148319 | |||||
圆皮带 | WANDRES | 9109415 | |||||
C位置板 | WANDRES | 4145899 | |||||
测量传感器 | HBM | SLB-700A/06 | |||||
定位轴 | JERGENS | 49961 M25*M20 | |||||
灯 | HERBERT | 612063013 灯612000000 | |||||
阀 | HYDROTECHNIK | 15-300L/MIN/P/MAX/400BAR | |||||
TF放大器 | HBM | 1-MP55DP | |||||
电缆 | NSD | 2990VW-1E66085-H 4P-S | |||||
传感器 | MTS | RHM1100MD701S2G2101 | |||||
引导刷 | WANDRES | 4145802 | |||||
引导刷 | WANDRES | 4145954 | |||||
线性刷仪 | WANDRES | 9506161 | |||||
隔离放大器 | KNICK | P27000H1 | |||||
液位开关 | KOBOLD | NKP-6401/33M NKP-6401/3 | |||||
绝缘监测器 | BENDER | IR425-D4-2 | |||||
(上导、下导摆度) 电容式位移传感器 | VIBROSYSTM | PCS302 | |||||
真空发生器 | PISCO | VHH12-601真空发生器 | |||||
备件 | REXROTH | R911299930 MHD071B-061-PG3-UN | |||||
流量开关 | SIKA | VHS32M01171/61 | |||||
固化软件 | REXROTH | R911328760 | |||||
轴卡 | REXROTH | R911328098 | |||||
固化软件 | REXROTH | R911328741 | |||||
MMC卡 | REXROTH | R911296958 | |||||
矫直机的控制板 | REXROTH | R911328869 CSH01.3C-PB-ENS-NNN-CCD-S2-S-NN-FW | |||||
备件 | REXROTH | R911328507 CSH01.3C-PB-ENS-EN2-CCD-S2-S-NN-FW | |||||
备件 | REXROTH | R911328501 CDB01.1C-PB-ENS-ENS-NNN-NNN-S2-S-NN-FW | |||||
备件 | REXROTH | R911328716 FWA-INDRV*-MPD-07VRS-D5-1-NNN-NN | |||||
备件 | REXROTH | R911312503 HAB01.1-0350-1640-NN | |||||
备件 | ROTARY | M/N:FA7963 UI BOARD FA7963 | |||||
传感器 | MTS | RPS0700MD601A01 | |||||
备件 | WAGNER+GRIMM | EE 100 Nr:51734 A | |||||
备件 | HAGER | EEN100 | |||||
备件 | HAGER | EE171 | |||||
备件 | HAGER | EE002 | |||||
三通阀门 | HORA |
要避免存留脏物、杂物进入减压阀减压保障系统。新建或者改造工程的减压系统管网,很可能遗留沙粒、麻丝、杂物。投运前,一般都应进行水冲洗,满足清洁要求后,后装上减压阀和过滤器滤芯,这样才能避免杂物流入减压阀,杜绝减压阀卡芯现象。在系统进入工作后,保障减压系统的水流畅通与否,与设置在系统上的过滤器流通能力关系密切,如滤芯被杂物严重吸附,则会影响减压阀的工作,为此必需对过滤器进行定期检查,及时清除污秽。实践表明这项工作2至3个月必须进行一次,有些可调式(弹簧式、薄膜式)减压阀,其主阀或者导阀自身设置过滤器,同样需要定期拆洗滤芯。
2.1用1备的减压阀组应定期轮换工作。大部分高层建筑生活给水减压阀减压保障系统,是以给水竖向分区设置的,一般设在每一给水分区总管上。考虑到众多用户的用水可靠安全性(住宅每一分区有几十户*百户,公共建筑如宾馆、饭店,每一分区有几十套客房……),设计时减压阀应两套并列安装(1用1备)。减压通路两侧都辅以闸阀或蝶阀,可启闭任一减压通道,为使并列的两套减压阀通道能正常工作,常规一个月轮流交换一次,搁置时间过长减压通道死水结垢,减压元件阀芯会卡住失效。
3.应及时排除管道中的积气。当空气进入减压管网或管网内随压力变化时气体从水中析出,这时区域内用户的水压极不稳定;处在供水不利点用水器更是压力变化急骤,有时呈现虚假的峰值压力,有时还会抽吸断水,还有管网会伴随撞击声。产生这种现象,会影响燃气热水器、电热水器等稳定工作,严重时会被毁坏;对各种盥洗器具的进水连接管破坏力也很大,特别是目前常用的一些复合型连结软管,其强度较差,因此爆管的事件屡有发生;有些水表无法正确计量,出现用户不用水,水表也会不断地转动。为杜绝这类事故,应检查屋顶水箱生活给水总管的蓄水高程是否满足,如不满足水箱出水口处会产生水旋,吸入空气。排除这一故障可调整水箱内液位控制器的低水位高程,经验表明一般低水位距出水口应不小于0.3m。也可反复开启设置在分区、减压系统两侧的压力表放气旋塞,把已进入管网内的空气徐徐排出。如采取上述措施后,在分区总管末梢以下的一些用水器还出现上述现象,可以在这些部位增设自动排气装置。
4.注意减压阀的减压保障系统。无论选用比例式还是可调式减压阀,其减压比P1∶P2不宜选择过大,一般应控制在5∶1之内。超过这个范围易产生气蚀现象,损坏阀件,产生啸叫噪音。有些活塞式减压阀,制造厂在其阀体上加工一个直径1.5mm左右的小孔,其功能是让阀芯运动时起到透吸气作用,维护管理时应注意千万不要将小孔塞住,否则影响减压阀的正常运行。
5.加强减压阀保障系统的管理,要注意观察减压阀本身的工作动态。阀前、阀后压力数值接近,表明减压阀本身已存在故障。即活塞式减压阀的阀芯与阀体间的平面密封橡胶件损坏;薄膜式可调型减压阀主阀膜片有裂痕和O型圈损坏,及导阀连通管堵塞,造成减压阀减压作用削弱或者失效。这对分区管网危害*,特别是许多用水设备可能因超压力而出现爆管,必须及时修复。比例式(活塞型)减压阀阀体上的透吸气小孔如出现滴漏不止,表明阀芯上几档O型密封圈已经磨损,要更换密封件。但在修理拆装减压元件时,要谨慎细心,调换内密封件;清理杂物时,应因势利导,不要用金属棒、硬梗撬阀的活动部位,使用木榔头和木柄敲击震动,慢慢拆卸阀内部件。修理完毕后重新安装时,一定要和阀门上的流向指示保持一致。
6.注意检查比例式减压阀的安装位置。高层内减压阀设计安装的位置不妥,会出现减压阀阀后压力忽高忽低,管网压力严重偏离允许范围,伴随毁坏淋浴器,水管爆裂和损坏用户水表等事故发生;有时也会水流不畅,分区内出现无规律的断水现象,影响用户用水。出现类似事故,检查整个减压阀减压分区给水系统,无疑点可找;拆卸减压阀过滤器等元件并无异常;有些物业管理单位甚至怀疑减压阀的技术性能,多次调换新的减压阀,也不能解决问题。这时可从检查比例减压阀设计安装位置是否合理着手,认真检查管网系统是否存在等位倒虹管现象,即分区的输出管路标高相近。此类情况在主、副楼同一屋顶水箱,下给水供水系统中很容易出现。发现这些问题,可以考虑把比例减压阀安装位置提高一个层面(不能提得太高,必须顾全分区内用水设备的承压规范要求);也可在主、副楼内,分设两组独立的比例减压阀给水系统。