品牌
经销商厂商性质
上海所在地
瑞士HUBA 501压力变送器 01,501.99036,501.99037 501.99230,501.99229
面议DWYER德威尔2-5000系列Minihelic®Ⅱ压差表 2-5000-1kpa,2-5000-125pa,2-5000-250pa 2-5000-500pa
面议BPS水压差开关
面议HUBA 619压力开关 619
面议P7620A水管式压力传感器 P7620A,P7620A1016 P7620A1018,P7620A1020
面议瑞士HUBA 511压力变送器 511,511.931003141,511.930003141
面议Setra 209压力传感器 Setra,209,setra 209 Setra modle 209,modle209
面议瑞士HUBA 692压差变送器 692,692.9190071A1,692.9170071A1 692.9300071A1
面议瑞士huba 694微压差变送器 694,694.9132150,694.9122150 694.9142150,694.916215
面议HUBA 699空气压差传感器 699
面议setra 261C HVAC专用微差压传感器 setra 261C,setra 261,Model 261C
面议SETRA 265微差压传感器 setra 265,Model 265,265
面议型号分类
| 型号名称 | | 型号代码 | | 敏感元件 | | 阻值表 | | 长度 | | 注释 | |
| | | | | | | | | | |||
| | | | | | | | | | | | |
| SD-Tn3-12 | 40-20 0014 | | NTC 3kΩ at 25°C | | B25/50 3935 | | 120mm (4.7) | | | | |
| | | | | | | | | | | | |
| SD-Tn10-12 | | 40-20 0002 | | NTC 10kΩ at 25°C | | B25/50 3935 | | 120mm (4.7) | | Vector standard | |
| SD-Tn11-12 | 40-20 0015 | | NTC 10kΩ at 25°C | | B25/50 3630 | | 120mm (4.7) | | | | |
| SD-Tn20-12 | 40-20 0016 | | NTC 20kΩ at 25°C | | B25/50 4200 | | 120mm (4.7) | | | | |
| SD-Tn100-12 | 40-20 0017 | | NTC 100kΩ at 25°C | | B25/50 4200 | | 120mm (4.7) | | | | |
| SD-Tp1-12 | 40-20 0023 | | PT100 | | EN60751 | | 120mm (4.7) | | | | |
| SD-Tp2-12 | 40-20 0024 | | PT1000 | | EN60751 | | 120mm (4.7) | | | | |
| | | | | | | | | | | | |
| SD-Tk5-12 | 40-20 0025 | | NI1000 | | 5000 ppm/K | | 120mm (4.7) | | | | |
| | | | | | | | | | | | |
| SD-Tn3-20 | 40-20 0018 | | NTC 3kΩ at 25°C | | B25/50 3935 | | 200mm (7.9) | | | | |
| | | | | | | | | | | | |
| SD- Tn10-20 | | 40-20 0003 | | NTC 10kΩ at 25°C | | B25/50 3935 | | 200mm (7.9) | | Vector standard | |
| SD- Tn11-20 | 40-20 0020 | | NTC 10kΩ at 25°C | | B25/50 3630 | | 200mm (7.9) | | | | |
| SD- Tn20-20 | 40-20 0021 | | NTC 20kΩ at 25°C | | B25/50 4200 | | 200mm (7.9) | | | | |
| SD- Tn100-20 | 40-20 0022 | | NTC 100kΩ at 25°C | | B25/50 4200 | | 200mm (7.9) | | | | |
| | | | | | | | | | | | |
| SD- Tp1-20 | 40-20 0026 | | PT100 | | EN60751 | | 200mm (7.9) | | | | |
| SD- Tp2-20 | 40-20 0027 | | PT1000 | | EN60751 | | 200mm (7.9) | | | | |
| | | | | | | | | | | | |
| SD- Tk5-20 | 40-20 0028 | | NI1000 | | 5000 ppm/K | | 200mm (7.9) | | | | |
| | | | | | | | | | | | |
附件 | | | | | | | | | | | | |
与 AMI 配套使用可以测量管道内温度. | | | | | | | | | | |||
| 型号名称 | | 型号代码 | | | | 描述 | | 长度 | | | |
| | | | | | | | | | | ||
| | | | | | | | | | | | |
| AMI-S5 | 40-50 0007 | | | | | | 50mm (2.0) | | | | |
| AMI-S7 | 40-50 0008 | | | | 不锈钢 | | 75mm (3.0) | | | | |
| AMI-S10 | 40-50 0009 | | | | | | 100mm (3.9) | | | | |
| AMI-S15 | 40-50 0010 | | | | | | 150mm (5.9) | | | | |
| | | | | | | | | | | | |
安装 探测器应直接安装在管道上,在此位置内能很好的测量混合的空气。安装的位置应该距风机的出风口有两三米。
安装在回风风道上,安装位置可以在回风风道任意处,一般在接近空调箱的回风风道上。
在风道上开一个 8mm 的孔,然后把温度传感器探针插入到风道里面。用 2 个 10mm 长的自攻螺丝 将外壳牢固的固 定在风道上。 安装水路管道上,需要焊接一个 G1/2 的内螺纹管箍。把 AMI 附件直接拧入管箍内,然后插入传感器 安装接线需要按照接线图: 这个传感器需要两个线,通常用 1mm²的非屏蔽的双绞线