免费会员 经销商
参考价:
具体成交价以合同协议为准
免费会员 经销商
花30秒询价,你会知道什么叫优势;花60秒咨询,你会知道什么叫服务;
合作一次,你会知道什么叫质量!以质量求生存,以信誉求发展。我将提供*的质量,服务作为自已zui重要的责任。
有您的信任才有我的明天。期待你的询价!!!
上海励辉自动化科技有限公司
24小时
在 线 商 务
直线销售 电 话:
传 真:
联 系 人: 陈宝全 (销售工程师) 欢迎询价
上海励辉自动化科技有限公司在经营活动中精益求精,具备如下业务优势:
上海励辉*低价销售西门子PLC,200,300,400,1200,西门子PLC附件,西门子电机,西门子人机界面,西门子变频器,西门子数控伺服,西门子总线电缆现货供应,咨询系列产品,折扣低,货期准时,并且备有大量库存. *有效
西门子数控伺服系统:802C S、802D SL、810D DE、820D SL、840C CE、840D DE、840D SL、840Di SL、S120数控 系 统、数 控 伺 服 驱 动 模 块、控 制 模 块、电 源模 块、备 品 备 件 等。
本公司产品质量按西门子原厂质量标准,产品质保一年,按西门子原厂包装标准,西门子原装*,按厂家执行标准,需方收到货后七日内可提出异议!!!
我们卖的不是价格,卖的是诚信卖的是品质。
优惠虽易,质量不易,且买且珍惜。
With SOFTNET for PROFIBUS, PCs can be connected to programmable controllers, such as SIMATIC S7, over PROFIBUS.
The following user interfaces are available:
SOFTNET is available for the following interfaces:
The operating systems that are supported are listed in the ordering data for the SOFTNET software.
Software for DP protocol (SOFTNET-PB DP)
SOFTNET-PB DP offers DP master class 1 functionality. The central controller exchanges information with the DP slaves (e.g. ET 200S) in a specified, constantly repeating message cycle. The OPC programming interface provides the PC programmer with function calls for data transfer. The DP interface also provides the SYNC and FREEZE functions as well as activation and deactivation of slaves.
The DP function expansions for masters of Class 1 make it possible to perform read and write functions (DS_READ, DS_WRITE) as well as acknowledgement of alarms (ALARM_ACK) at the same time as processing cyclic data communication. Data that are to be transferred in acyclic mode (e.g. parameterization data) are only rarely changed in comparison to the cyclic measured values, and are transferred at lower priority in parallel with the cyclic high-speed user data transfer. Alarm acknowledgement by the master ensures reliable transfer of the alarms from DP slaves.
In addition to DP master Class 1 services, SOFTNET-PB DP also provides DP Master Class 2 services. Devices of this type are used (programming, configuration or control devices) during start-up, for configuring the DP system or for controlling the plant during normal operation (diagnostics). The DP programming interface provides the following services: Reading master diagnostics, slave diagnostics, inputs/outputs of a slave, configuration data and modifying slave addresses. These extended DP functions comprise non-isochronous access to the parameters and measured values of a slave (e.g. field devices of process automation and inligent HMI devices). This type of slave must be supplied with extensive parameter data during start-up and during normal operation (DS_READ, DS_WRITE).
A DP slave is an I/O station that reads in input data and transfers output data to the I/O. The volume of input and output information is determined by the user application and can be a maximum of 122 bytes each. For the slave interface, a simple example GSD file is provided that can be adapted by the user to the slave application. This GSD file can be configured using any configuration tool which complies with the PROFIBUS DP specification IEC 61158/EN 50170, e.g. STEP 7 or NCM PC.
Software for PG/OP communication
Special programming device packages are not required because the drivers are included in the STEP 7 scope of supply.
Software for S7 communication (SOFTNET-PB S7)
SIMATIC S7 system components communicate with each other using S7 communication functions. The S7 programming interface provides programming device/PC user programs with access to SIMATIC S7 system components. This provides easy, flexible access to the data of the SIMATIC S7 controller.
The following services are available with S7 communication:
Administrative services
Data transfer services
Software for open communication (SEND/RECEIVE based on the FDL interface)
This interface based on Layer 2 is used for communication between
used
SEND/RECEIVE offers the following services:
This interface is included in SOFTNET-PB DP and SOFTNET-PB S7. No configuration is necessary.
User interfaces
The OPC server included in the respective software package can be used as the standard programming interface for the PROFIBUS DP, open communication and S7 communication protocols for linking automation technology applications to OPC-capable Windows applications (Office, HMI systems, etc.).
Mode of operation
With SOFTNET, the complete protocol stack is processed in the PC.
This architecture means that in contrast to the CP 5613 or CP 5614 products, the performance of the SOFTNET packages is dependent on the configuration or loading of the PC used.
Configuration
Performance data | CP 5612/CP 5622/CP 5711 |
---|---|
Mono protocol mode |
|
Number of connectable DP slaves | max. 60 |
Number of FDL tasks waiting | max. 50 |
Number of PG/OP and S7 connections | max. 8 |
| DP-V0, DP-V1 with SOFTNET-PB DP |
| DP-V0, DP-V1 with SOFTNET-PB DP slave |