$item.Name

首页>仪表上游>工具>安装附件

参考价:

  • 面议
IWATSU SS-240与SS-250岩崎高频交直流霍尔电流探头

具体成交价以合同协议为准

2022-07-16长沙市
型号
长沙力高捷创仪器有限公司

免费会员 代理商

该企业相似产品
频率响应分析仪,功率放大器,高压探头,大电流探头,图示仪,晶体管特性分析仪,探针台
产品简介
Wide bandwidth - DC to 100 MHz (SS-250)/DC to 50 MHz (SS-240A)
详细信息

image.pngSS-250/SS-240A



Supports various applications

Displays its capabilities in full force in current waveform observation and wide-band applications such as switching power supplies, optical disc manufacturing lines, and semiconductor power devices.



Features

image.pngLow noise characteristics for easy milliampere order observation


image.pngWide bandwidth - DC to 100 MHz (SS-250)/DC to 50 MHz (SS-240A)


image.pngHigh sensitivity and wide bandwidth implemented through use of thin-film Hall element

image.pngPower can be provided directly from the oscilloscope
(DS-5600A/DS-5400A series of oscilloscopes with DS-579 : Probe power option)


image.pngClamp type, enabling easy measurement without cutting the electrical circuit

image.pngEquipped with a function that provides simple protection for excessive input

image.pngCan also be used with measuring instruments that do not have a power supply for probes (power can be provided through the optional probe power supply PS-26)




Specifications

Item

SS-250

SS-240A

Bandwidth

DC to 100 MHz
(-3dB)

DC to 50 MHz
(-3dB)

Maximum input current

Maximum input range

30 A rms

30 A rms

Maximum peak current

50 A peak, non-continuous

50 A peak, non-continuous
50 A peak at pulse width <= 10 μs

Output sensitivity

0.1 V/A

Sensitivity accuracy

•±1.0% of reading ±10 mA for probes only (in the range from 0 to 30 A rms, DC, and AC 45 to 66 Hz)
•±2.0% of reading for probes only (50 A peak or less and over 30 A rms, DC, and in the range of AC 45 to 66 Hz)

Noise

2.5 mA rms or less (observation using an oscilloscope with a 20 MHz band)

Power consumption

5.3 VA max.

5.6 VA max.

Power supply voltage

±12 V ±0.5 V

Operating temperature and humidity

0°C to +40°C, 80% RH or less
(no condensation)

Storage temperature and humidity

-10°C to +50°C, 80% RH or less
(no condensation)

Operating elevation

2000 m or less (air pressure approx. 79 kPa), indoor

Effects of external magnetic field

5 mA max. or equivalent (in DC, 60 Hz, 400 A/m AC magnetic field)

20 mA max. or equivalent (in DC, 60 Hz, 400 A/m AC magnetic field)

Maximum usable circuit voltage

300 V, CAT I (insulating conductor)

Conductor diameter that can be measured

ø 5 mm

Cable length

Sensor cable

Approx. 1.5 m

Power cable

Approx. 1 m

Size

Sensor part

Approx. 175 (W) x 18 (H) x 40 (D) mm

Termination part

Approx. 27 (W) x 55 (H) x 18 (D) mm

Weight

Approx. 240 g

Approx. 230 g

Complied with standards

Safety

EN61010-2-032:2002
Measurement category I (expected overvoltage: 1500 V),
Pollution degree: 2

EMC

EN61326:1997+A1:1988+A2:2001

Accessories

Instruction manual (1),
hard case (1)

Instruction manual (1),
soft case (1)

* Values for performance/accuracy items are at 23°C ±5°C and 30 minutes after power-on.



Characteristics figures

SS-250 Continuous maximum input range (frequency derating)

image.png

SS-240A Continuous maximum input range (frequency derating)

* These current probes can be used as-is with oscilloscopes that feature power supply connectors for active probes. Current probes can also be used with oscilloscopes without power supply connectors for active probe, when used in combination with the optional power supply (PS-26).

* With the power supply for current probe PS-26, if the current being measured is large, it may not be possible to use two SS-250/SS-240A units at the same time.

Caution

1.Use this product in circuits that do not exceed the maximum usable circuit voltage, so as to avoid accidents such as short-circuits and physical injuries.

2.Do not use this product with bare conductors, so as to avoid accidents such as physical injuries and short-circuits when the leading end of the clamp core is opened.