$item.Name

首页>测量/计量>电子测量>拉力表

参考价:

  • 面议
LU-1000N/eLU-1000N 拉力表

具体成交价以合同协议为准

2022-11-04
型号
广州诚敏电子科技有限公司

免费会员 经销商

该企业相似产品
电量传感器/变送器/互感器,功率计,记录仪,校验仪,数显仪,万用表,PH计,电导率仪,指针表,示波器,
产品简介
IMADA测力计用测压元件:LU-50N/eLU-50N、LU-100N/eLU-100N、LU-200N/eLU-200N、LU-500N/eLU-500N、LU-1000N/eLU-1000N、LU-2000N/eLU-2000N
详细信息

LU-1000N/eLU-1000N测压元件

测压元件:

LU-50N、LU-100N、LU-200N、LU-500N、LU-1000N、LU-2000N

eLU-50N、eLU-100N、eLU-200N、eLU-500N、eLU-1000N、eLU-2000N

SW1-100N、SW1-200N、SW1-500N、SW1-1000N、SW1-2000N、SW1-5000N

eSW1-100N、eSW1-200N、eSW1-500N、eSW1-1000N、eSW1-2000N、eSW1-5000N

SW3-10KN、SW3-20KN、eSW3-10KN、eSW3-20KN

LMU-50N、LMU-100N、LMU-200N、LMU-500N

eLMU-50N、eLMU-100N、eLMU-200N、eLMU-500N

ZD1-1000N、ZD1-2000N、ZD1-5000N、ZD1-10KN、ZD1-20KN

eZD1-1000N、eZD1-2000N、eZD1-5000N、eZD1-10KN、eZD1-20KN

DPU-1000N、DPU-2000N、DPU-5000N、DPU-10KN、DPU-20KN

eDPU-1000N、eDPU-2000N、eDPU-5000N、eDPU-10KN、eDPU-20KN

DPU-2N、DPU-5N、DPU-10N、DPU-20N、DPU-50N、DPU-100N、DPU-200N、DPU-500N

eDPU-2N、eDPU-5N、eDPU-10N、eDPU-20N、eDPU-50N、eDPU-100N、eDPU-200N、eDPU-500N

Feature

- Strain gauge type load cell.
- Able to connect your sample with the 2 sides of the load cell.
- For both tension test and compression test.
- Amplifier is necessary to read load values and output them to external equipment.

Specifications forUniversal Load Cell LU series

ModelLU series
CapacityPlease refer the model list
Rated output+/-0.9~1.4mV / V
Nonlinearity0.5%R.O
Hysteresis0.5%R.O
Recommended voltage(allowable applied voltage)2~5V AC or DC(7V AC or DC)
Safe overload rating150%
Working environment(allowable temperature)0~70 degree Celsius(-10~70 degree Celsius)
Temperature influence for 0 degree0.05%/ degree Celsius
Temperature influence for output0.05%/ degree Celsius
CableApprox.3m(with a connector)
DimensionsPlease refer the dimension

Specifications for eZ-Connect series Load Cell

ModeleLU series
CapacityPlease refer the model list
Accuracy+/-1.0%F.S. or less
Safe overload rating150%
Working environment(allowable temperature)0~70 degree Celsius(-10~70 degree Celsius)
CableApprox.3m(with a connector)
DimensionsPlease refer the dimension

Model List of Universal Load Cell LU series

ModeleZ-Connect series modelCapacityDiameter
LU-50NeLU-50N50NM8 P1.25
LU-100NeLU-100N100N
LU-200NeLU-200N200N
LU-500NeLU-500N500N
LU-1000NeLU-1000N1000N
LU-2000NeLU-2000N2000N

 Dimensions

(Unit:mm)

Dimensions for LU series load cell

Feature

-The female screws on both end of sensor make easy mount on equipment.
-Approved for IP67. Waterproof and dust-proof.
-Strang for splashing water.
-Connecting an amplifier is necessary to output force value.
-IP67 is approved. Waterproof and dust-proof.

Specifications  for Waterproof and Dust-proof Load Cell SW series

ModelSW1 seriesSW3 series
CapacityRefer to the model listRefer to the model list
Rated output+/-2mV/V+/-2mV/V
Nonlinearity+/-0.25%R.O+/-0.25%R.O
Allowable voltage10V DC10V DC
Safe overload rating120%120%
Working environment(allowable temperature)-10~50 degree Celsius(-30~50 degree Celsius)-10~50 degree Celsius(-30~50 degree Celsius)
Temperature influence at 0 point0.005%/ degree Celsius0.005%/ degree Celsius
Temperature influence for output0.005%/ degree Celsius0.005%/ degree Celsius
CableApprox.0.5~4m(Curl cord)Approx.5m
DimensionsRefer to the dimensionRefer to the dimension
International ProtectionIP67*IP67*

*Only the sensor parts are approved IP. An amplifier (an indicator) and connecting parts are not approved.

Specifications  for eZ-Connect series Load Cell

ModeleSW1 serieseSW3 series
CapacityPlease refer to the model listPlease refer to the model list
Accuracy+/-0.5%F.S or less+/-0.5%F.S or less
Safe overload rating120%120%
Working environment(allowable temperature)-10~50degree Celsius(-30~50degree Celsius)-10~50degree Celsius(-30~50degree Celsius)
CableApprox.0.5~4m(Curl Cord)Approx.5m
DimensionsRefer to the dimensionRefer to the dimension
International ProtectionIP67*IP67*

*Only the sensor parts are approved IP. An amplifier (an indicator) and connecting parts are not approved.

Model List of Waterproof and Dust-proof Load Cell SW1 series

ModeleZ-Connect series modelCapacityDiameter
SW1-100NeSW1-100N100NM6
SW1-200NeSW1-200N200NM6
SW1-500NeSW1-500N500NM8
SW1-1000NeSW1-1000N1000NM8
SW1-2000NeSW1-2000N2000NM10
SW1-5000NeSW1-5000N5000NM10

Model List of Waterproof and Dust-proof Load Cell SW3 series

ModeleZ-Connect series modelCapacityDiameter
SW3-10kNeSW3-10kN10kNM16
SW3-20kNeSW3-20kN20kNM16

Dimensions

(Unit:mm)

SW series dimension

Feature

- Strain gauge type load cell
- Extra small size: φ18×H25(mm).
- For both tension test and compression test.
- Sensor’s threads are male screws: You can connect samples with them.
- Amplifier is necessary to read load values and output them to external equipment.

Specifications for LMU series Extra Small Load Cell

CapacityPlease refer the model list
Rated output+/-1mV / V+/-10%(20N is 0.75mV/V~1mV/V)
Nonlinearity0.5%R.O
Hysteresis0.5%R.O
Recommended voltage(allowable applied voltage)1~3V AC or DC(5V AC or DC)
Safe overload rating120%R.O
Working environment(allowable temperature)0~50 degree Celsius(-10~60 degree Celsius)
Temperature influence for 0 degree0.005%/ degree Celsius
Temperature influence for output0.01%/ degree Celsius
CableApprox.2m(with a connector)
DimensionsPlease refer the dimension

 Specifications for eZ-Connect series Load Cell

ModeleLMU series
CapacityPlease refer the model list
Accuracy+/-1.0%F.S or less
Safe overload rating120%R.O
Working environment(allowable temperature)0~50 degree Celsius(-10~60 degree Celsius)
CableApprox.2m(with a connector)
DimensionsPlease refer the dimension

Model List of LMU series Extra Small Load Cell

ModeleZ-Connect series modelCapacityDiameter
LMU-50NeLMU-50N50NM5 P0.8
LMU-100NeLMU-100N100N
LMU-200NeLMU-200N200N
LMU-500NeLMU-500N500N

Dimensions

(Unit:mm)Dimensions for LMU series load cells

Feature

- It is available for high capacities between 1000N and 20kN.
- It can be built in a narrow space by the small shape and the light weight.
- The sensor can be screwed with the both ends. The fixation and the installation are easy.
- IP67 is approved. Waterproof and dust-proof.
- Connecting an amplifier is necessary to output the load value.

Specifications for ZD series High Capacity Load Cell

ModelZD series
CapacityPlease refer the model list
Rated output1.5mV/V
Nonlinearity0.25%R.O
Hysteresis-
Recommended voltage(allowable applied voltage)-
Safe overload rating150%
Working environment-20~80 degree Celsius
Temperature influence for 0 degree0.02%/ degree Celsius
Temperature influence for output0.02%/ degree Celsius
CableApprox.3m(with a connector)
DimensionsPlease refer the dimension
International ProtectionsIP67*

*International Protection is approved for the load cell only.  The amplifier (indicator), the connecting part and the connector are not approved.

Specifications for eZ connect series Load Cell

ModeleZD series
CapacityPlease refer the model list
Accuracy+/-0.5%F.S. or less
Safe overload rating150%
Working environment(allowable temperature)-20~80 degree Celsius
CableApprox.3m(with a connector)
DimensionsPlease refer the dimension
International ProtectionsIP67

*International Protection is approved for the load cell only. The amplifier (indicator), the connecting part and the connector are not approved.

Specifications for ZD series High Capacity Load Cell

ModeleZ-Connect series modelCapacityDiameter
ZD1-1000NeZD1-1000N1000NM12P1.75
ZD1-2000NeZD1-2000N2000N
ZD1-5000NeZD1-5000N5000N
ZD1-10kNeZD1-10kN10kN
ZD1-20kNeZD1-20kN20kN

Dimensions

(Unit:mm)

Feature

- Strain gauge type load cell
- High capacity type available in capacity up to 20kN.
- For both tension test and compression test.
- Amplifier is necessary to read load values and output them to external equipment.

Specifications for DPU series High Capacity Load Cell

ModelDPU-1000N~20kN
CapacityPlease refer to the model list.
Rated output2mV/ V±1%
Nonlinearity0.05%R.O.
Hysteresis0.05%R.O.
Recommended voltage(allowable applied voltage)10V DC(18V DC)
Safe overload ratingPlease refer to the model list.
Working environment-10~+70 degree Celsius
( allowable temperature)(-20~+80 degree Celsius)
Temperature influence for 0 degree0.01%/ degree Celsius
Temperature influence for output0.01%/ degree Celsius
WeightApprox. 800g
DPU-10kN:Approx.1.7kg
DPU-20kN:Approx.2.3kg
Cable3m(with a connector)
DimensionRefer to dimensions.

 Specifications for eZ-Connect series Load Cell

ModeleDPU  -1000N~20kN
FeatureFor large force
CapacityPlease refer to the model list.
Accuracy+/-0.2% F.S. or less
Safe overload ratingPlease refer to the model list.
Working environment( allowable temperature)-10~+70 degree Celsius(-20~+80 degree Celsius)
WeightApprox. 800g
DPU-10kN:Approx.1.7kg
DPU-20kN:Approx.2.3kg
Cable3m(with a connector)
DimensionRefer to the dimensions.

 Model List of DPU series High Capacity Load Cell

ModeleZ-Connect series modelCapacitySafe overload ratingThread
DPU  -1000NeDPU-1000N1000N240%M10
DPU-2000NeDPU-2000N2000N120%
DPU-5000NeDPU-5000N5000N
DPU-10kNeDPU-10kN10kN120%N/A*
DPU-20kNeDPU - 20kN20kN

*There is no thread on DPU-10kN and 20kN. Instead of a thread, there is a female screw M18P1.5 depth 22. It is also possible mounting a thread as an option.

Dimensions

(Unit:mm)

Feature

- Strain gauge type force sensor
- Easy to mount on your equipment with screws.
- For both tension and compression.
- Amplifier is necessary to read load values and output them to external equipment.

Specifications for DPU series Load Cell (Force Sensor)

ModelDPU-  2N~500N
CapacityPlease refer to the model list.
Rated output1mV / V±10%(2N, 5N is 0.9~1.25 mV/ V±10%)
Nonlinearity0.12%R.O.
Hysteresis0.12%R.O.
Recommended voltage(allowable applied voltage)5V DC (12V DC)
Safe overload ratingPlease refer to the model list.
Working environment( allowable temperature)0~+50 degree Celsius(-10~+60 degree Celsius)
Temperature influence for 0 degree0.02%/ degree Celsius
Temperature influence for output0.01%/ degree Celsius
WeightApprox. 325g
Cable2m(with a connector)
DimensionRefer to dimensions.

 Specifications for eZ-Connect series Load Cell (Force Sensor)

ModeleDPU-2N~500N
FeatureFor standard force
CapacityPlease refer to the model list.
Accuracy+/-0.2% F.S. or less
Safe overload ratingPlease refer to the model list.
Working environment( allowable temperature)0~+50 degree Celsius(-10~+60 degree Celsius)
WeightApprox. 325g
Cable2m(with a connector)
DimensionRefer to the dimensions.

Model list of DPU series Load Cell (Force Sensor)

ModeleZ-Connect series modelCapacitySafe overload ratingThread
DPU-  2NeDPU-2N2N150%M6
DPU-5NeDPU-5N5N
DPU-10NeDPU-10N10N200%
DPU-20NeDPU-20N20N
DPU-50NeDPU-50N50N
DPU-100NeDPU-100N100N
DPU-200NeDPU-200N200N
DPU-500NeDPU-500N500N

Dimensions

(Unit:mm)

Dimensions for DPU series force sensor

推拉力计用手动测试台:

SVL-220、SVL-220-S、NLV-220、NLV-220-C、NLV-220-T、NLV-220-C-S、NLV-220-T-S、NLH-220、NLH-220-S、SVH-220、SVH-220-S、KV-11-S、SH-220、SH-220-S、HV-110 、HV-110-S、HV-110-L、HV-110-L-S、HV-220、HV-220-S、HV-220-L、HV-220-L-S、HV-300、HV-300-S、HV-500、HV-500-S、HV-750、HV-750-S

推拉力计用电动测试台:

MX-110   MX-275   MX-1100   MX2-110  MX2-275  MX2-550   EMX-275

MH2-110   MH-275   MH-750

ZPS-LM系列推拉力计:

ZPS-LM-0.4    ZPS-LM-1    ZPS-LM-4    ZPS-LM-11    ZPS-LM-44    ZPS-LM-110

ZPS-LM-220 ZPS-LM-440    ZPS-LM-1100 ZPS-LM-2200    ZPS-LM-4400

ZPS-DPU系列推拉力计:

ZPS-DPU-0.4   ZPS-DPU-1   ZPS-DPU-4   ZPS-DPU-11   ZPS-DPU-44   ZPS-DPU-110

ZPS-DPU-220 ZPS-DPU-440   ZPS-DPU-1100   ZPS-DPU-2200   ZPS-DPU-4400

ZPH系列推拉力计:

ZPH-440   ZPH-1100

ZP系列推拉力计:

ZP-0.4   ZP-1   ZP-4   ZP-11   ZP-44   ZP-110   ZP-220

Z2S-LM系列推拉力计:

Z2S-LM-1   Z2S-LM-4   Z2S-LM-11   Z2S-LM-44   Z2S-LM-110   Z2S-LM-220

Z2S-LM-440   Z2S-LM-1100 Z2S-LM-2200   Z2S-LM-4400

Z2S-DPU系列推拉力计:

Z2S-DPU-0.4   Z2S-DPU-1   Z2S-DPU-4   Z2S-DPU-11   Z2S-DPU-44   Z2S-DPU-110

Z2S-DPU-220 Z2S-DPU-440   Z2S-DPU-1100   Z2S-DPU-2200   Z2S-DPU-4400

Z2H系列推拉力计:

Z2H-440  Z2H-1100

Z2系列推拉力计:

Z2-0.4   Z2-1   Z2-4   Z2-11   Z2-44   Z2-110   Z2-220

DS2系列推拉力计:

DS2-0.4   DS2-1   DS2-4   DS2-11    DS2-44   DS2-110   DS2-220

ZTS-LM/ZTA-LM系列推拉力计:

ZTS-LM-2   ZTA-LM-2   ZTS-LM-4   ZTA-LM-4   ZTS-LM-11   ZTA-LM-11   ZTS-LM-44   ZTA-LM-44 ZTA-LM-110   ZTS-LM-110   ZTS-LM-220   ZTA-LM-220    ZTA-LM-550   ZTS-LM-550   ZTS-LM-1100 ZTA-LM-1100   ZTS-LM-2200   ZTA-LM-2200 ZTS-LM-4400   ZTA-LM-4400

ZTS-DPU/ZTA-DPU系列推拉力计:

ZTS-DPU-0.4   ZTA-DPU-0.4 ZTS-DPU-1    ZTA-DPU-1 ZTS-DPU-4    ZTA-DPU-4

ZTS-DPU-11    ZTA-DPU-11 ZTS-DPU-44    ZTA-DPU-44 ZTS-DPU-110

ZTA-DPU-110 ZTS-DPU-220    ZTA-DPU-220 ZTS-DPU-550    ZTA-DPU-550

ZTS-DPU-1100 ZTA-DPU-1100 ZTS-DPU-2200    ZTA-DPU-2200 ZTS-DPU-4400    ZTA-DPU-4400

ZTS/ZTA系列推拉力计:

ZTS-0.4  ZTS-1  ZTS-4  ZTS-11  ZTS-44  ZTS-110  ZTS-220  ZTS-550  ZTS-1100

ZTA-0.4  ZTA-1  ZTA-4  ZTA-11  ZTA-44  ZTA-110  ZTA-220  ZTA-550  ZTA-1100

ESH/PSH系列推拉力计:

ESH-200  ESH-300  ESH-400  ESH-500  ESH-100KGF  ESH-200KGF  ESH-300KGF

ESH-1000N ESH-2000N  ESH-3000N

PSH-200  PSH-300  PSH-400  PSH-500  PSH-100KGF  PSH-200KGF  PSH-300KGF

PSH-1000N PSH-2000N  PSH-3000N

FB/FS/PS系列推拉力计:

FB-32OZ   FB-80OZ   FB-2   FB-5   FB-10   FB-20    FB-30   FB-50    FB-100

FB-1KG   FB-2KG   FB-3KG   FB-5KG   FB-10KG   FB-20KG   FB-30KG   FB-50KG

FB-10N   FB-20N   FB-30N   FB-50N   FB-100N   FB-200N   FB-300N   FB-500N

FS-1K、FS-2K、FS-3K、FB-5K、FB-10K、FB-20K、FB-30K、FB-50K

PS-32OZ   PS-80OZ   PS-2   PS-5   PS-10   PS-20   PS-30   PS-50   PS-100

PS-0.5KG   PS-1KG   PS-2KG   PC-3KG   PS-5KG   PS-10KG   PS-20KG   PS-30KG

PS-50KG PS-10N   PS-20N   PS-30N   PS-50N   PS-100N   PS-200N   PS-300N   PS-500N

电动测量支架:

MX-500N、MX-500N-S、MX-500N-S-L、MX-500N-E、MX-500N-E-L、MX-1000N、MX-1000N-S、MX-5000N、MX2-500N、MX2-1000N、MX2-2500N、MX2-500N-L、MX2-1000N-L、MX2-2500N-L、EMX-1000N、EMX-1000N-L、MH-1000N、MH-300、MH2-500N

 手动式测量支架:

KV-50N、KV-50N-S、MSF-50N、F-S Master-MSL、SVL-1000N、SVH-1000N、HV-500NII、HV-500NII-S、HV-1000N、HV-3000N、HV-3000N-S、HV-1000N-S、SH-1000N、SH-1000N-S、SH-3000N、SH-3000N-S

LU-1000N/eLU-1000N、

相关技术文章

同类产品推荐

企业未开通此功能
详询客服 : 0571-87858618
提示

仪表网采购电话