传导干扰(CE)测试系统,用来测量被试设备(EUT)在正常工作状态下通过电源线、信号/控制线对周围环境所产生的传导干扰是否符合要求。如果干扰信号过大,就会影响整个电网的用电质量,从而干扰到其他电器的正常运行。
详细信息

传导干扰(CE)测试系统主要遵循标准

CISPR 11: Industrial, scientific and medical (ISM) radio-frequency equipment and similar equipment –Radio-frequency disturbance characteristics –Limits and methods of measurement

CISPR 12: Vehicles, boats and internal combustion engines—Radio disturbance characteristics—Limits and methods of measurement for the protection of off board receivers

CISPR 13: Sound and evision broadcast receivers and associated equipment –Radio disturbance characteristics –Limits and methods of measurement

CISPR 14-1:Electromagnetic compatibility . Requirements for household appliances, electric tools and similar apparatus -Part 1: Emission

CISPR 15: Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

CISPR 22:Information technology equipment – Radio disturbance characteristics –Limits and methods of measuremen

传导干扰(CE)测试系统主要测量受试设备(EUT)在正常工作状态下通过电源线、信号端口、控制端口对周围环境所产生的干扰,测试频率范围主要为9kHz~30MHz。不同产品的干扰限值由不同标准规定,但基本方法是一样的。系统主要由EMI测试接收机、人工电源网络(LISN)和EMC测试软件组成。其中人工电源网络可以在给定的频率范围内,为干扰电压的测量提供标准规定的50Ω阻抗,并使受试设备(EUT)与电源相互隔离。
当EUT电流过大,或无法使用LISN进行测量时,如EUT控制端口,可使用高阻抗电压探头配合接收机测量。

传导干扰(CE)测试系统配置

测试设备:EMI接收机、人工电源网络、EMC测试软件、电压探头、电流探头等(根据需要决定配置)。
测试环境:电磁屏蔽室
 测试时,人工电源网络的输出端子与受试设备端子应相距0.8m,并用一根0.8m长的三芯软缆中的两根动力线连接。台式受试设备的高度要求0.8m以上,落地式设备的高度要求0.1m以上。墙面和地面要放置接地金属板,EUT距离垂直接地金属板0.4m。