$item.Name

首页>实验仪器>科教仪器>教学用电学仪器

参考价:

  • 面议
GCL 接地电流限流器

具体成交价以合同协议为准

2021-10-23
型号
天津力测科技有限公司

免费会员 其他

该企业相似产品
激光测振仪
产品简介
GCL能够在接地电流超出时提供主动保护
详细信息

111.jpg

GCL能够在接地电流超出时提供主动保护。GCL比AE Techron功放中标配的地面电流保护器(一个2.7ohm电阻器,设计在功放机壳地与COM端口/常用输出端口之间)的性能更好。这是因为在工作中,GCL将功放设置为待机状态,并且在故障发生时提供可视化指示,同时支持方便重置。

GCL – 接地电流限流器1.png

AE Techron’s GCL provides active protection against excessive ground current. It is superior to the factory-default ground-current protection on many AE Techron amplifiers (a 2.7-ohm resistor between the amplifier’s Chassis Ground and COM or Sampled Common output terminals) because it places the amplifier


in Standby, provides a visual indication that a fault has occurred, and can be easily reset.


The GCL protection module is ideal for environments where recirculating ground currents are likely or amplifiers might be incorrectly connected. It is recommended when amplifiers will be connected in multiple configurations or will be used by inexperienced staff members.


The GCL combines several functions into one convenient DB-25 package. A comparator circuit monitors the voltage difference between the system’s input ground and earth/safety ground. If the voltage differential between these two grounds exceeds ±4V, the GCL will automatically place the amplifier in Standby. In addition, the GCL has a second level of protection that monitors the current flow between signal ground and earth ground. When the current between these exceeds safe


levels, the current is limited. This combination of current limit and voltage monitoring provides very robust protection against real-life measurement mistakes and DUT failures.


When the GCL module protections are activated, the red LED located on the top of the GCL will illuminate and the amplifier will be placed in Standby. When the ground potential between the two terminals decreases to a safe level, the red LED will turn off, and the amplifier will be brought out of Standby mode.


The GCL plugs into the DB-25 Interlock/IO connector located on the amplifier’s back-panel SIM input card and can be used on all AE Techron amplifiers that use a SIM card. Since the GCL is a “feedthrough” device, the DB-25 Interlock/IO connector can still be used for other purposes and applications when the GCL is in place. 


Specifications

Power Supply: Self-powered through DB-25 connector

Activation Level: ±4V (1.5 A)

Dimensions(HxWxD): 2.5 in. x 2.2 in. x 0.7 in. (64 mm x 56 mm x 18

mm)


Features

• Provides active protection against excessive

ground current.

• Replaces the 2.7-ohm resistor used on many

AE Techron amplifiers.

• Automatically places the amplifier in Standby.

• Red LED notifies the user of GCL activation.

• Fast, easy installation.


Refer to Figure 1 and complete the following steps to

install the GCL module.

1. Remove the 2.7-ohm resistor installed between

the COM or Sampled Common terminal and the

Chassis Ground terminal located on the amplifier’s

back panel.

2. Plug the GCL module into the DB-25 connector located

on the SIM input card on the amplifier’s back

panel. Tighten the GCL’s two mounting screws to

attach the GCL firmly to the amplifier back panel.

3. Attach one wire from the GCL to the amplifier’s

COM/Sampled Common output terminal.

4. Attach the other wire from the GCL to the amplifier’s


相关技术文章