技术文章

灼热丝试验仪检验报告

来源: 深圳市德迈盛测控设备有限公司

2016/8/19 14:13:32 558

 

出厂检验报告

Inspect Report

 

报告编号:                           1 ,  共  4 

Report No.                           page        of

  

 

客户名称:

Customer’s Name:   

 

仪器名称:

Apparatus Name:  灼热丝试验仪

 

型号规格:

Type specification: ZRS-H

 

仪器编号:

Apparatus No.: 

 

检验结论:

Inspect Result: 合     格

 

制造厂商:

Manufacturer:      深圳市德迈盛C测控设备有限公司

  :

Inspected by:

 

检验员:

Inspected by:

检验日期:                            月    日

Inspect Date:                     Y      M    D


    

                DIRECTIONS           

                                     第 2页,  共 3页

                                                          Page       Of

 

The test method is conformed with ISO 9001(2000Edition) Quality System

 

Without signature , the report will be null and valid. And alteration will caused the date invalid.

 

The report can be used freely , but it should be used whole. The testing results are only responsible for the performance of equipment at the test moment. The precision must according to the degree of carefulness and the frequency of use.

 

Reference documents for the test:

 

 

Main measure apparatus is used in test:

器具名称/型号                  编号               证书号

Name of apparatus               Serial No.           Certificate No.

温度校正仪:             

秒表:

数显卡尺:

拉力计

 

6.检验地点,环境条件:

Inspect place and Environment condition.

地点:                        温度:                    相对湿度:

Place:                        Temperature:               RH:

 

 

 

 

公司地址: 广东省深圳市*园科苑路10号

 

                                             

邮政编号:                                    Post Cade:

 

 

 

         

Results  of  calibration

 3, 3 

                                                                 Page      of

.

 报告编号:                                        :                   

 Report No                                             Record No.                     

检验结果:

2.配件:   齐全

3.功能:   正常

4.各项技术指标的检测结果如下:

 

4.1温度示值误差测量:

设定值

实际值

允许误差

误差

结论

( ° )

( ° )

±2.0

%

(P/F)

100

100.6

 

-0.6

pass

200

200.9

-0.9

pass

300

300.9

-0.9

pass

400

401.1

-0.9

pass

500

501.5

-0.9

pass

600

602.8-

-0.9

pass

700

702.8-

-0.9

pass

800

803.8-

-0.9

pass

900

904.8-

-0.9

pass

1000

1005.8-

-0.9

pass

 

 

 

4.2试验力示值误差测量:

设定值

实际值

允许误差

误差

结论

(N)

(N)

±2.0

%

(P/F)

1

1.15

 

1.0

pass

 

4.3 小车速度示值误差

设定值

实际值

技术要求

误差

结论

 mm/s

mm/s )

 

%

(P/F)

10---25

15

 

 

pass

4.4 试验时间:

设定值

实际值

技术要求

误差

结论

s

s

 

%

(P/F)

10

10

 

 

pass

20

20.1

 

1

pass

30

30.3

 

1

pass

 

4.4 试验容积:

序号

项目

技术要求

实测结果

结论

1

白松木板

120X120X10mm

 

(P/F)

2

试验容积

 

0.5m³

pass

 

 

相关产品

提示